Page 2 - Contents; Related Manuals
Related Manuals 2 3A0237L Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Heated Hose Bundle Part Numbers . . . . . . . . . . . . 3 Fluid Temperature Sensor (FTS) . . . . . . . . . . . . . 4 Heated Whip Hose . . . . . . . . . . . . . . . . . . . . . . . 4 Individual ...
Page 3 - Heated Hose Bundle Part Numbers
Heated Hose Bundle Part Numbers 3A0237L 3 Heated Hose Bundle Part Numbers Each hose contains an A component hose, a B component hose, and an air hose (1/4 npt x 1/4 npsm, m x f). ✿ If ordered as replacement hose for a HFR hose bun-dles, reference manual 3A0237 not 309572. ★ All heated hose bundles a...
Page 4 - Heated Whip Hose
Heated Hose Bundle Part Numbers 4 3A0237L Fluid Temperature Sensor (FTS) Heated Whip Hose ★ All heated whip hoses are CE approved. Part No. Fittings Description Maximum Fluid Pressurepsi (MPa, bar) 258756 JIC to JIC Fluid Temperature Sensors for dual heat zones with stainless steel fittings 5000 (34...
Page 5 - Individual Hoses
Individual Hoses 3A0237L 5 Individual Hoses A Side Heated Hoses (Red) ✿ If ordered as replacement hose for a HFR hose bun-dles, reference manual 3A0237 not 309572. ★ All heated hoses are CE approved. Part No. ID in. (mm) Lengthft (m) JIC Fittings Maximum Fluid Pressurepsi (MPa, bar) Carbon Steel Hea...
Page 6 - Individual A Side Heated Whip Hose
Individual Hoses 6 3A0237L A Side Unheated Hoses (Red) Individual A Side Heated Whip Hose Part No. ID in. (mm) Lengthft (m) JIC Fittings Maximum Fluid Pressurepsi (MPa, bar) Carbon Steel Unheated 262173 1/4 (6) 5 (1.5) 5/5 3500 (24, 241) 262175 1/4 (6) 10 (3) 5/5 3500 (24, 241) 262177 1/4 (6) 25 (7....
Page 8 - Individual B Side Heated Whip Hose
Individual Hoses 8 3A0237L B Side Unheated Hoses (Blue) Individual B Side Heated Whip Hose Part No. ID in. (mm) Lengthft (m) JIC Fittings Maximum Fluid Pressurepsi (MPa, bar) Carbon Steel Unheated 262174 1/4 (6) 5 (1.5) 6/6 3500 (24, 241) 262176 1/4 (6) 10 (3) 6/6 3500 (24, 241) 262178 1/4 (6) 25 (7...
Page 9 - Applicator Kits
Applicator Kits 3A0237L 9 Applicator Kits The table below lists applicators that can be used with the heated hoses and identifies which applicators require sole-noid kits. See Related Manuals for the applicator manual numbers. NOTE: The MD2 valves must use one of the chemical connection kits to conn...
Page 10 - MD2 Valve Applicator Kits
Applicator Kits 10 3A0237L MD2 Valve Applicator Kits Part No. (Series) MD2 Valve (see manual 312185) MD2 Handle Chemical Connection Kit Electric (255208) Lever (255249) Pneumatic (255206) Carbon Steel (24D414) Stainless Steel (24D162) 24D500 255179 (1:1 with soft seats) ✔ 24D501 ✔ ✔ 24D502 ✔ ✔ 24D50...
Page 11 - Warnings; WARNING
Warnings 3A0237L 11 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol aler ts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-...
Page 14 - Important Two-Component Material Information; Isocyanate Conditions
Important Two-Component Material Information 14 3A0237L Important Two-Component Material Information Isocyanate Conditions Material Self-ignition Keep Components A and B Separate Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO...
Page 15 - Changing Materials; A and B Components
A and B Components 3A0237L 15 Changing Materials • When changing materials, flush the equipment mul-tiple times to ensure it is thoroughly clean. • Always clean the fluid inlet strainers after flushing. • Check with your material manufacturer for chemical compatibility. • Most materials use ISO on t...
Page 16 - Installation; Description
Installation 16 3A0237L Installation Description The heated hose maintains proper fluid temperature while dispensing. Fluid hoses are marked with red tape for ISO/hard-ener/minor volume side, blue tape for RES/resin/major volume side. Fittings have different sized threads to pre-vent incorrect conne...
Page 17 - Connect Heated Hoses
Installation 3A0237L 17 Connect Heated Hoses 1. Lay heated hoses end to end, matching the color coding. Red for component A (ISO), blue for compo-nent B (RES). 2. Connect fluid hoses (A, B). 3. Connect signal cables (13). NOTE: Do not connect the main air supply to the air hose at this time. 4. Conn...
Page 18 - Incorrect
Installation 18 3A0237L NOTE: Be careful not to cut or nick copper strands. If more than five strands are cut or nicked, trim wire and re-strip. New hoses are pre-stripped at correct length; remove insulation to expose bare wire. a. Ensure strip length is correct by fitting ferrule over exposed wire...
Page 19 - Cap plugs
Installation 3A0237L 19 f. Insert cap plugs over setscrews. See F IG . 11. g. Wrap connector and wire on each side of con-nector in black electrical tape to help seal out moisture. Ensure 1 in. (25.4 mm) of wire on each side of connector is wrapped. 7. Connect cables (F). Leave slack (G) in cables a...
Page 21 - Connect Solenoid Kit; Connect Splitter
Installation 3A0237L 21 Connect Solenoid Kit A solenoid kit is required for some applicators used with Graco Metering Systems. See Individual Hoses on page 5 to see which applicators require a solenoid kit. NOTE: To ensure proper operation of valve, install the solenoid kit within 15 ft (4.5 m) of t...
Page 22 - Check Hoses for Leaks; Protective Covering
Installation 22 3A0237L 4. For 24C757: Connect valve (201) to the B side pump guard (GD) with screws (208) and washers (209). 5. Remove motor cover and connect solenoid cable (206) to cable (2B). 6. For 24D160 and 24D161: Connect the valve (201) between the last hose bundle and the whip hose with zi...
Page 23 - Operation
Operation 3A0237L 23 Operation 1. Connect air hose (C) to main air supply if equipped. 2. Connect electrical connectors (D) to connector from fluid manifold (M) or accessory control box. See , page 16. Connect hose cable (F) to cable from pro-portioner fluid manifold (M) or accessory control box. Co...
Page 24 - Maintenance; Clean Orifice
Maintenance 24 3A0237L Maintenance 1. Before disconnecting or repairing hoses, relieve all fluid pressure and shut off electrical power to pro-portioner. See system operation manual. 2. Be sure fluid is cool before disconnecting hoses. Instructions for Replacing Individual A or B Hose 1. Before disc...
Page 26 - Bundle Individual Whip Hoses
Maintenance 26 3A0237L Bundle Individual Whip Hoses Individual whip hoses must be bundled with scuff guards and air and signal cables. Follow the instructions below to bundle single and dual heat zone whip hose bundles. See F IG . 21 on page 27. 1. Lay out the A and B material hoses with the male fi...
Page 27 - Dual Heat Zone Heated Whip Hose Bundle
Maintenance 3A0237L 27 F IG . 21: Whip Hose Bundles Dual Heat Zone Heated Whip Hose Bundle male fittings Single Heat Zone Heated Whip Hose Bundle A Side B Side A Side B Side male fittings 16 in.(406.4 mm) 24 in.(609.6 mm) 27 in.(685.8 mm) female fittings 6 in.(152.4 mm) 10 in.(254 mm) male connector...
Page 28 - Bundle Individual Heated Hoses
Maintenance 28 3A0237L Bundle Individual Heated Hoses Individual hoses must be bundled with a scuff guard, FTS cable(s), and air and signal cables.Follow the instructions below to bundle individual heated hoses for dual and single zone heat. See F IG . 22 on page 29. 1. Lay out the A and B material ...
Page 29 - Dual Heat Zone Heated Hose Bundle Shown
Maintenance 3A0237L 29 F IG . 22: Heated Hose Bundles female connectors male fittings male connectors female fittings 1 in.(25.4 mm) 18 in.457.2 mm) 19 in.(482.6 mm) 10 in.(254 mm) 4 in.101.6 mm) 3 in.(76.2 mm) 25 33 A Side B Side 21 22 Machine End 2 in.50.8 mm) B Side A Side 21 22 28 29 29 33 32 25...
Page 30 - Parts; Whip Hoses; Dual Heat Zone Heated Whip Hose
Parts 30 3A0237L Parts Whip Hoses NOTE: A FTS assembly must connect the heated hose and whip hose. See page 35. Dual Heat Zone Heated Whip Hose Single Heat Zone Heated Whip Hose A Side B Side A Side B Side 4 10 5 5 4 3 8 10 13 10 8 8 12 5 1 2 13 12 10 10 8 4 3 4 1 2
Page 31 - Heated Whip Hoses
Parts 3A0237L 31 Heated Whip Hoses Common Parts ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ✖ Not shown. ‡ Purchase locally. ✿ Order 24E961 for replacement scuff guard. Contains 30 ft (9 m) of braided polyester mesh. ★ Order 24E954 replacement scuff guard. Cont...
Page 32 - Heated Hose Bundles
Parts 32 3A0237L Heated Hose Bundles female connectors male fittings male connectors female fittings 5 33 A Side B Side 21 22 Machine End 2 in.50.8 mm) B Side A Side 21 22 28 29 29 33 32 25 23 23 25 32 5 24 24 Dual Heat Zone Heated Hose Bundle Shown NOTE: A FTS assembly must connect the heated hose ...
Page 33 - Dual Zone Heated Hose Bundles
Parts 3A0237L 33 Dual Zone Heated Hose Bundles Common Parts ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ✿ Order 24E954 for replacement scuff guard. Contains 200 ft (60.9 m) of braided polyester mesh. ✖ Not shown. ‡ Purchase locally. Varied Parts Ref. No. Part N...
Page 34 - Single Zone Heated Hose Bundles
Parts 34 3A0237L Single Zone Heated Hose Bundles Common Parts ▲ Replacement Danger and Warning labels, tags, and cards are available at no cost. ✿ Order 24E954 for replacement scuff guard. Contains 200 ft (60.9 m) of braided polyester mesh. ✖ Not shown. ‡ Purchase locally. Varied Parts Ref. No. Part...
Page 35 - Using Fluid Temperature Sensors For Single Heat Zones; 58758 Carbon Steel Fluid Temperature Sensor; Using Fluid Temperature Sensors for Dual Heat Zones; 58757 Stainless Steel Fluid Temperature Sensor
Parts 3A0237L 35 Using Fluid Temperature Sensors For Single Heat Zones 258758 Carbon Steel Fluid Temperature Sensor Using Fluid Temperature Sensors for Dual Heat Zones 258757 Stainless Steel Fluid Temperature Sensor FTS Kits 25 TI1435a 52 51 27 3a 23 Heated Fluid Hose Fluid Temperature Sensor 22 21 ...
Page 37 - MD2 Applicator Kits
Parts 3A0237L 37 MD2 Applicator Kits See MD2 Valve Applicator Kits table on page 10 for kit descriptions. MD2 Applicator Kits ★ MD2 valve kits only. See Solenoid Kits on page 38 for parts. 24F227 Ratio Check Assembly To check spray ratio with Fusion and Graco EP guns. See manual 3A0861 for more info...
Page 38 - Accessories; Scuff Guard; Solenoid Kits
Accessories 38 3A0237L Accessories Scuff Guard Use to keep hose clean and protect it from damage. Solenoid Kits Not all applicator kits require a solenoid kit. See Applicator Kits , page 9. 24C757 Machine Mount Kit Part Description 24E954 200 ft (60.9 m) braided polyester mesh. Fold back over itself...
Page 40 - Technical Data
Technical Data 40 3A0237L Technical Data Category Data Maximum Fluid Working Pressure See page 3 Maximum Air Working Pressure 130 psi (0.9 MPa, 9 bar) Maximum Operating Temperature 180°F (82°C) Wetted Parts Nylon, Zinc-Plated Carbon Steel, 303 Stainless Steel, Butyl Total Heating Load (2 hoses) 1/4”...
Page 42 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...