Page 2 - Contents
Related Manuals 2 3A0235G Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Complete Supply Pump Systems . . . . . . . . . . . . . 3 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Isocyanate Conditions . . . . . . . . . . . . . . . . . . ....
Page 3 - Complete Supply Pump Systems
Complete Supply Pump Systems 3A0235G 3 Complete Supply Pump Systems Most packages include all air and fluid fittings and hoses. Approvals are only for the pumps and not for the entire package. ★ Complete Package only comes with one pump, air and fluid fittings, and hoses. Complete Package (fluid and...
Page 4 - Warnings; WARNING
Warnings 4 3A0235G Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:• Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, por...
Page 6 - Isocyanate Conditions; Changing Materials
Isocyanate Conditions 6 3A0235G Isocyanate Conditions Material Self-ignition Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become susp...
Page 7 - A and B Components
A and B Components 3A0235G 7 A and B Components IMPORTANT! Material suppliers can vary in how they refer to plural component materials. Be aware that when standing in front of the manifold on proportioner: • Component A (Red) is on the left side. • Component B (Blue) is on the right side. For all ma...
Page 8 - Grounding; Position Drums; Installation; Feed Pump
Grounding 8 3A0235G Grounding The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. Pump: follow instructions in separate feed pump man- ual, supplied. ...
Page 11 - Pumps
Installation 3A0235G 11 Husky 515 and 716 1. Place riser tube (202) into drum. Tighten bung adapter securely. 2. For carbon steel supply pump systems, Install swivel fitting (102) in pump (201) fluid outlet. 3. Connect hose (103) between swivel fitting (102) and GMS swivel fluid inlet fitting. 4. In...
Page 12 - Install Air Supply Kit; Connect Air Lines
Install Air Supply Kit 12 3A0235G Install Air Supply Kit T2 2:1, Husky 515, Husky 716, and Husky 1050 Kits 1. Supply clean, dry filtered air to feed pumps. 2. See manual 309827 to install air supply kit. Air Regulator Kit 248829 The air regulator kit (7) is only used with the Monark kits. 1. Install...
Page 13 - Operation; Startup; Shutdown; Maintenance
Operation 3A0235G 13 Operation Startup 1. See Load fluid with feed pumps in system opera- tion manual. 2. Open feed pump air regulator. 3. Open feed pump bleed-type master air valve. 4. Adjust air to feed pump with needle valve. NOTE: • Cold, viscous material may be difficult to prime. Use needle va...
Page 14 - Parts
Parts 14 3A0235G Parts Complete Supply Pump Systems Each complete supply pump system includes a fluid supply kit, air supply kit, and desiccant dryer. See parts lists on pages 15. Pump Material Two Pump Systems One Pump Systems Complete Pump System Fluid Supply Kit (1) (See Page 16) Complete Pump Sy...
Page 15 - Complete Supply Pump Systems, continued; Husky and T2 2:1 Kits
Parts 3A0235G 15 Complete Supply Pump Systems, continued ★ See Fluid Supply Kits on page 16. ❖ Only for Monark 5:1 kits. Husky and T2 2:1 Kits See illustration on page 14. 24D096 and 24E399 Monark 5:1 5 Gallon Feed Pump Kit 24D095 and 24E398 Monark 5:1 Kit55 Gallon Feed Pump Kit Ref. Part Descriptio...
Page 16 - Carbon Steel Husky Kits
Parts 16 3A0235G Fluid Supply Kits (1) Carbon Steel Husky Kits Stainless Steel Husky Kits 24D104 Monark 5:1 5 Gallon Kit 24D105 55 Gallon Monark 5:1 Kit 246898 and 24D103 T2 2:1 Kits 101 102 103 r_246481_3a0235a_1a r_24d101_3a0235a_1a 103 101 103 101 r_24D104_3a0235a_1a 101 103 102 103 TI10282a 101
Page 17 - Carbon Steel Fluid Supply Kits
Parts 3A0235G 17 Fluid Supply Kits (1), continued Each fluid supply kit contains two pumps with riser tubes, fittings, and hoses needed to supply fluid from the pumps to the proportioner. Use the tables below to identify what parts are used for the carbon steel and stainless steel fluid supply kits....
Page 19 - Pump with Riser Tube Kits
Parts 3A0235G 19 Pump with Riser Tube Kits 246366 Husky 515 Pump 246367 Husky 716 Pump Pump Kit No. Material Husky 515 246366 CS 233052 (see manual 309116) Plastic Husky 716 246367 CS 233057 (see manual 309116) SS Husky 1050 24D329 CS 24D097 SS T2 2:1 295616 (see manual 311882) SS Monark 5:1, 5 Gall...
Page 20 - Pumps with Riser Tube Kits, continued
Parts 20 3A0235G Pumps with Riser Tube Kits, continued 24D329 CS Husky 1050 Pump 24D097 SS Husky 1050 Pump Ref. Part Description Qty. 201 647673 PUMP, Husky 1050; 24D332, see 313435 1 202 246419 RISER TUBE KIT; 24D332, see page 22 1 203 214961 HOSE, suction; 3/4 npt (mbe); 3/4 in. (19 mm) ID; 6 ft (...
Page 22 - Accessories; Return Tube Accessories
Accessories 22 3A0235G Accessories Riser Tube Kit, 246419 Return Tube Accessories See manual 309852 for installation and parts. Circulation Kits See manual 309852 for installation and parts. 246483 Air Supply Kit See manual 309827 for installation and parts. 15C381 Desiccant Dryer Cartridge 233048 H...
Page 23 - Technical Data
Technical Data 3A0235G 23 Technical Data Maximum air input pressure T2 Feed Pump Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 psi (1.2 MPa, 12 bar)Monark 5:1 Feed Pump Kit . . . . . . . . . . . . . . . . . . . . . . . . 180 psi (1.2 MPa, 12 bar)Husky 716 . . . . . . . . . . ....
Page 24 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...