Page 2 - Contents
Models 2 3A0019J Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Isocyanate Conditions . . . . . . . . . . . . . . . . . . . . . . 5 Material Self-ignition . . . . . . . . . . . . . ....
Page 3 - Warnings; WARNING
Warnings 3A0019J 3 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol aler ts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-s...
Page 5 - Isocyanate Conditions; Changing Materials
Isocyanate Conditions 3A0019J 5 Isocyanate Conditions Material Self-ignition Moisture Sensitivity of Isocyanates Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become susp...
Page 6 - Component Identification; 0cc pump shown
Component Identification 6 3A0019J Component Identification Key: A Displacement Rod (inside main cylinder) B Throat Retainer C Throat Cartridge D Outlet Housing E Main Cylinder F Crossover Tube G Tie Bolt H Inlet Housing J Inlet Cap K Fluid Outlet L Fluid Inlet (bottom of inlet housing) M Pump Mount...
Page 7 - Flushing
Pressure Relief Procedure 3A0019J 7 Pressure Relief Procedure 1. Select Park on Pump Control Switch if available, or turn off. 2. Turn off feed pumps. 3. Trigger gun to relieve pressure. 4. Close gun inlet valves. 5. Close fluid supply inlet valves. 6. Open all fluid drain valves in the system, havi...
Page 8 - Repair; Required Tools; Inlet Housing Disassembly; Inlet Housing Assembly
Repair 8 3A0019J Repair Required Tools • Large vise • Set of adjustable wrenches • O-ring pick • 1/2 in. bit socket • Rubber mallet • Torque wrench • 2 in. and 3 in. sockets • Anti-seize lubricant • Removable strength thread locker Inlet Housing Disassembly 1. Relieve pressure and flush system. See ...
Page 9 - Pump Disassembly
Repair 3A0019J 9 Pump Disassembly 1. Relieve pressure and flush system. See Pressure Relief Procedure and Flushing , page 7. 2. Remove inlet hose and drain inlet housing (7). 3. Horizontally clamp pump on outlet housing (7) in vise, use 1/2 in. hex bit socket to loosen all four tie bolts (5) from in...
Page 11 - Pump Assembly
Repair 3A0019J 11 Pump Assembly NOTE: Piston assembly tool is NOT needed for 10cc-15cc pump sizes. 1. Install piston seal installation tool (PT) from pump repair kit on displacement rod (15). Hand tighten. 2. Apply grease to seal and bearing surface of dis-placement rod (15). 3. Install u-cup (17) a...
Page 14 - Parts
Parts 14 3A0019J Parts 5cc, 10cc, and 15cc Pumps 1. Lubricate seals, o-rings, lead-in’s and moving parts with grease. Apply one stripe of removable strength anaerobic sealant on threads. Torque to 50-ft-lbs (67.5 N•m). Assemble and torque after displacement rod (15) is assembled through throat retai...
Page 17 - Pump Parts
Parts 3A0019J 17 Pump Parts ✓ Refer to Table 1: Cylinder O-ring Kits for kit number. ✿ Refer to Table 2: Cylinder Kits for kit number. ✠ Refer to Table 3: Crossover Tube Kits for kit number. ★ Refer to Table 4: Throat Cartridge Kits for kit number. ✖ Refer to Table 5: Throat Retainer Kits for kit nu...
Page 20 - Seal Kits
Parts 20 3A0019J Seal Kits Table 7: Seal Kits Reference Number and Quantity Included in Kit Pump Size Seal Kit 1 2 8 16 17 25 26 5cc 262561 2 2 4 1 1 1 1 10cc 258923 2 2 4 1 1 1 1 15cc 258929 2 2 4 1 1 1 1 20cc 258935 2 2 4 1 1 1 1 25cc 258941 2 2 4 1 1 1 1 30cc 258947 2 2 4 1 1 1 1 40cc 258793 2 2 ...
Page 21 - Displacement Rod Kits
Parts 3A0019J 21 Displacement Rod Kits 14 15 15 26 17 25 16 16 14 17 16 17 40cc Displacement Rod Shown 60cc Displacement Rod Shown 10cc Displacement Rod Shown 14 16 17 26 25 33
Page 23 - Dimensions
Dimensions 3A0019J 23 Dimensions All pump sizes have the same dimensions. r_257891_3a0019_22h C B A A (Length) in. (mm) B (Inlet) in. npt (f) C (Outlet) SAE (f) 13.36 (339.34) 3/4-14 3/4-16
Page 24 - Outlet Housing Mounting Hole Layout
Outlet Housing Mounting Hole Layout 24 3A0019J Outlet Housing Mounting Hole Layout All pumps have the same outlet housing mounting hole layout. 5.9 in (150 mm) r_257891_3a0019_23h
Page 25 - Technical Data
Technical Data 3A0019J 25 Technical Data Maximum working pressure . . . . . . . . . . . . . . . . . . . . . . . 3500 psi (24MPa, 241 bar)Maximum operating temperature . . . . . . . . . . . . . . . . . . . 180° F (82° C)Maximum cycle rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 c...
Page 26 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents. Original instructions. This manual contains Eng...