Graco 309923F- User Manual
Graco 309923F– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Installation
- Page 3 – Minimum Pipe Size Recommendations; Air Pressure Drop Through Hose, by hose length and ID
- Page 4 – Operation; Pressure Adjustment; Maintenance and Repair; Air Filter; Air Regulator
- Page 5 – Parts; Air Control Assemblies
- Page 6 – Air Filters
- Page 8 – Graco Standard Warranty
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 USA
Copyright 2003, Graco Inc. is registered to I.S. EN ISO 9001
309923F
Instructions - Parts List
Air Controls
Air Control Assemblies
Provide clean, dry, regulated compressed air
*
Regulator maximum CFM is 50. See table below for maximum filter CFM.
See Air Regulator manual 309924 for additional information on air regulator.
Air Filters
With 5 micron filtration
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Part No.
Description
Includes
Maximum
Regulated Air
Pressure
Regulator*
Filter*
234398
2 regulated outlets and 1 filtered main
line outlet
234392
similar to
234396,
page 6
160 psi
(1.1 MPa, 11 bar)
234399
2 regulated outlets and 2 filtered main
line outlets with gauge and air cock
234392
234400
2 air regulators, each has 2 regulated
outlets and 1 filtered main line outlet
with gauge and air cock
234392
234411
2 regulated outlets and 1 filtered main
line outlet
234392
234410
Part No.
Description
Inlet
Outlets
Maximum
CFM
Maximum Air Inlet
Pressure
234396
Air Filter, bare
1/2” npt(f)
3/8” npt(f)
120 CFM
175 psi
(1.2 MPa, 12 bar)
234410
Air Filter, bare
1/2” npt(f)
3/8” npt(f)
1/4” npt(f)
plugged
75 CFM
234412
Air Filter, quick
coupler
1/4” npt(f)
1/4” npt(f)
1/4” npt(f)
plugged
75 CFM
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Installation 2 309923F Installation Before installing air line components, blow out the pipe line to remove debris. Be sure air to the regulator is clean. Erratic operation or loss of regulation is usually caused by dirt in the regulator. Use pipe compound or tape sparingly and only on male threads....
Shop Air Piping Layout 309923F 3 Minimum Pipe Size Recommendations Compressor Main Air Line HP CFM Length ft (m) Size in. (mm) 1-1/2 - 2 6 - 9 any 3/4 (19) 3 - 5 12 - 20 Up to 200 (61) 3/4 (19) Over 200 (61) 1 (25.4) 5 - 10 20 - 40 Up to 100 (30.5) 3/4 (19) Over 100-200 (30.5-61) 1 (25.4) Over 200 (...
Operation 4 309923F Operation Pressure Adjustment Turn clockwise to increase air pressure. Turn counterclockwise to decrease air pressure. Pressure Relief Procedure The following is a basic pressure relief procedure. Be sure to follow the specific pressure relief procedure in your spray gun and/or f...