Graco 309640A- User Manual

Graco 309640A

Graco 309640A– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

WARNING

To reduce the risk of fluid injection or splashing in the eyes or on the skin, relieve air and fluid pressure in the system before installing, cleaning or
changing tips. See

Pressure Relief Procedure

in gun or sprayer manual.

S

Keep clear of spray tip.

High-pressure spray or leaks can inject fluid into the body, resulting in serious injury which may

require amputation. Never spray without a tip guard (D).

S

Do not exceed 4050 psi (280 bar, 28 MPa) maximum working pressure.

Failure to install or use the RAC

t

tip guard assembly correctly may result in an undirected spray of fluid into the eyes or on the skin of the operator.

Be sure you:

S

Fully insert SwitchTip (A) into tip bore (C) in guard

S

Do not trigger gun with SwitchTip handle between

Spray

and

Clear

positions

S

Replace OneSeal

t

when replacing worn SwitchTip

B

A

C

D

Insert SwitchTip in tip bore and firmly thread
assembly onto gun

Use SwitchTip handle to remove OneSeal
from tip guard

Clearing a Clogged SwitchTip

Disassembling

Engage gun safety and rotate
SwitchTip handle to

Clear

posi-

tion

1

2

3

4

1

2

Disengage gun safety and trigger
gun into pail to clear SwitchTip

Engage gun safety and rotate
SwitchTip handle to

Spray

posi-

tion

Disengage gun safety and trigger gun
into pail to verify SwitchTip is clear

Note

:If SwitchTip is still clogged, follow

Pressure Relief Procedure

in gun or sprayer manual, and remove SwitchTip for

cleaning.

Clear

position

Spray

position

Use end of SwitchTip (A) to press OneSeal
(B) into tip guard (D), with curve matching tip
bore (C)

Installing

ti2508a

Instructions

RACX HandTite

t

Guard

Model 246215, Series A, 7/8 in. Guard

4050 psi (280 bar) Maximum Working Pressure

Model 246437, Series A, 11/16 in. Guard

4050 psi (280 bar) Maximum Working Pressure

D

Patented aerodynamic design virtually eliminates paint buildup.

D

Hand tighten on gun–no tools required.

D

Fits all Graco airless spray guns.

D

Use with RACX series SwitchTips only.

D

Graco RACX SwitchTip sold separately.