Graco 308325E- User Manual
Graco 308325E– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
- Page 3 – INJECTION HAZARD; TOXIC FLUID HAZARD
- Page 4 – Installation; Introduction; Pressure Relief Procedure
- Page 5 – Spring-Operated Regulator Installation
- Page 6 – Operation; Regulating Fluid Pressure; Flushing Procedure
- Page 7 – Notes
- Page 8 – Service; Air Operated Regulator
- Page 10 – Spring Operated Regulators
- Page 12 – Troubleshooting
- Page 13 – Parts; Spring-Operated Regulators
- Page 15 – Air-Operated Regulators
- Page 16 – Repair Kits; Dimensions; Use Only Genuine Graco Parts; Fitting Kits
- Page 18 – Performance Charts
- Page 20 – Graco Standard Warranty; Graco Information
For Use In Low-Pressure Systems Only
Fluid Flow up to 0.5 gpm (1.9 lpm)
Read warnings and instructions.
Spring-Operated Regulators
100 psi (0.7 MPa, 7 bar) Maximum Inlet Pressure
3 to 30 psi (.02 to 0.2 MPa, 0.2 to 2.1 bar)
Regulated Pressure Range
Model 236081, Series A
with no pressure gauge
Model 236449, Series A
with stainless steel pressure gauge
30 psi (0.2 MPa, 2.1 bar) gauge
Model 241976, Series A
with stainless steel pressure gauge
60 psi (0.4 MPa, 4.1 bar) gauge
_____________________________________
100 psi (0.7 MPa, 7 bar) Maximum Inlet Pressure
20 to 100 psi (.14 to 0.7 MPa, 1.4 to 7 bar)
Regulated Pressure Range
Model 236216, Series A
with no pressure gauge
Model 236450, Series A
with stainless steel gauge
100 psi (0.7 MPa, 7 bar) gauge
Air-Operated Regulators
100 psi (0.7 MPa, 7 bar) Maximum Inlet Pressure
3 to 100 psi (.02 to 0.7 MPa, 0.2 to 7 bar)
Regulated Pressure Range
Model 238159, Series A
with no pressure gauge
Model 236281, Series A
with stainless steel gauge
100 psi (0.7 MPa, 7 bar) gauge
Instructions
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 2001, Graco Inc. is registered to I.S. EN ISO 9001
Fluid Pressure Regulators
308325E
02725
CAUTION
The fluid supply system main line pressures
often exceed the pressure range of the gauge
supplied with regulator 236449. Exposing this
gauge to excessive pressure can damage the
gauge, causing inaccurate readings, and the
needle will not return to zero. Such damage is
not covered by the Graco warranty.
ACETAL MATERIAL, WATERBASE COMPATIBLE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
308325 2 Table of Contents Warnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . O...
308325 3 WARNING INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremelyserious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can alsocause serious injury. D Fluid injected into the skin might look ...
308325 4 Installation Introduction Fluid pressure regulators are used for accurate,positive control of the fluid pressure to spray guns,dispensing valves or atomizing heads. Regulators installed at circulating line take-offs orpumps are used to reduce main line pressure andmaintain the desired fluid...