Graco 308175P- User Manual

Graco 308175P

Graco 308175P– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
  • Page 3 – FIRE AND EXPLOSION HAZARD; MOVING PARTS HAZARD
  • Page 4 – Installation; Air Requirements; Installing the Agitator
  • Page 5 – Grounding
  • Page 6 – Operation; Operating the Agitator; Checking Fluid Viscosity
  • Page 7 – Service; Flushing; Servicing; Lubricating the Air Motor
  • Page 8 – Parts; Helix Mixer
  • Page 11 – Dimensions
  • Page 12 – Technical Data
  • Page 13 – Notes
Loading the manual

Instructions – Parts List

GRACO INC.

P.O. BOX 1441

MINNEAPOLIS, MN

55440–1441

Copyright 1991, Graco Inc. is registered to I.S. EN ISO 9001

AIR DRIVEN

Twistork

t

Helix Mixer

100 psi (0.7 MPa, 7 bar) Maximum Working Pressure

Model 224854, Series D

Carbon Steel Agitator

Model 235534, Series D

Stainless Steel Agitator

Table of Contents

Warnings

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operation

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Service

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Data

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Warranty

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Graco Information

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Patented in the United States and Europe

308175P

Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.

0359

II 1/2 G T3

ITS03ATEX11226

0908C

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD

2 308175 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. WARNING IN...

Page 3 - FIRE AND EXPLOSION HAZARD; MOVING PARTS HAZARD

308175 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition andresult in a fire or explosion and serious injury. D Ground all equipment. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric...

Page 4 - Installation; Air Requirements; Installing the Agitator

4 308175 Installation WARNING FIRE AND EXPLOSION HAZARDAlways maintain a minimum of 1 in. clearance between rotating agitator parts and container to prevent sparks from contact. air line lubricator agitator motor air line filter air regulator and gauge mix tank (reference only) Typical Installation ...

Other Graco Models

All Graco Other