Page 2 - Contents
Contents 2 3A6564D Contents Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Compon...
Page 3 - Models
Models 3A6564D 3 Models VAC Model 120 USA FinishPro II 595PC Pro 17E908 230 CEE 7/7 FinishPro II 595PC Pro 17E912 230 Europe Multicord FinishPro II 595PC Pro 17E913 230 Asia/ANZ FinishPro II 595PC Pro 17E915 110474 Certified to CAN/CSA C22.2 No. 68 Conforms to UL 1450
Page 4 - Warnings
Warnings 4 3A6564D Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual...
Page 8 - Component Identification
Component Identification 8 3A6564D Component Identification A Power/Function SelectorB Pressure Control C Air Hose ConnectionD Prime Valve E Gun Filter F Tip Guard G Spray Tip H Gun J Airless Hose K Power Cord L Trigger Lock M Fluid Intake N Drain Tube O Pressure Gauge P Pump R Fluid Outlet S Hanger...
Page 9 - Grounding; Power Requirements
Grounding 3A6564D 9 Grounding This sprayer is equipped with a power cord that has a ground wire and an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided; if it...
Page 11 - Trigger Lock
Pressure Relief Procedure 3A6564D 11 6. Put drain tube in a pail. Turn prime valve down. Leave prime valve in the down (drain) position until you are ready to spray again. 7. If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved: a. VERY SLOWLY loosen the tip g...
Page 12 - Setup
Setup 12 3A6564D Setup When unpacking sprayer for the first time or after long term storage perform setup procedure. When first setup is performed remove shipping plug from fluid outlet. 1. Connect Graco airless hose to fluid outlet. Use wrenches to tighten securely. 2. Connect other end of hose to ...
Page 15 - Startup
Startup 3A6564D 15 Startup 1. Perform Pressure Relief Procedure , page 10. 2. Turn pressure control to lowest pressure. 3. Set SELECTOR switch to AIRLESS position. 4. Place fluid intake in paint pail. Place drain tube in waste pail. 5. Turn pressure control to Fast Flush to start motor. Allow paint ...
Page 17 - Operation; Spray Tip Installation
Operation 3A6564D 17 Operation Spray Tip Installation 1. Perform Pressure Relief Procedure , page 10. 2. Engage trigger lock. 3. Insert seat (33a) into seat housing (35). 4. Insert seat housing (35) into air cap (6). 5. Insert seal (33b) over seat (33a). Use black seal for water-based materials and ...
Page 18 - Spray
Operation 18 3A6564D Spray When a RAC X™ FF LP Fine Finish Low Pressure reversible spray tip is used, spraying pressure can be lowered. Spraying at a lower pressure results in less overspray and reduces spray tip wear. Adjust the sprayer pressure to minimize overspray. Air-Assisted Spraying NOTE: In...
Page 20 - Clear Spray Tip Clog
Operation 20 3A6564D Clear Spray Tip Clog 1. Engage trigger lock. 2. For a Flat tip , perform Pressure Relief Procedure , page 10, remove and clean guard and tip. For a RAC tip , proceed to the next step. 3. Rotate tip 180° to UNCLOG position. NOTE: If Spray Tip is difficult to rotate when turning t...
Page 21 - Cleanup
Operation 3A6564D 21 Cleanup 1. Perform Pressure Relief Procedure , page 10. 2. Remove tip guard and spray tip. For additional information, see separate gun manual. Fast Flush Drain Tube 3. Remove fluid intake and drain tube from paint, wipe excess paint off outside. 4. Place fluid intake in flushin...
Page 24 - BlueLinkTM App
BlueLink™ App 24 3A6564D BlueLink™ App Download the Graco BlueLink app from the Apple App Store or Google Play to connect to the paint sprayer via Bluetooth ® . The BlueLink app allows you to access sprayer information, settings, statistics, and provides access to useful features such as WatchDog™, ...
Page 25 - Maintenance; Recycling and Disposal at End of Life
Maintenance 3A6564D 25 Maintenance Routine maintenance is important to ensure proper operation of your sprayer. Maintenance includes performing routine actions which keep your sprayer in operation and prevents trouble in the future. Maintenance can be scheduled and tracked via the Graco BlueLink app...
Page 26 - Troubleshooting; Mechanical/Fluid Flow
Troubleshooting 26 3A6564D Troubleshooting Mechanical/Fluid Flow 1. Follow Pressure Relief Procedure , page 10, before checking or repairing. 2. Check all possible problems and causes before disassembling the unit. Problem What to Check If check is OK, go to next check What to Do When check is not O...
Page 38 - NOTES
Page 39 - Sprayer
Sprayer 3A6564D 39 Sprayer See page 44 for Compressor parts. 2 1 2 See page 42. Ref. Torque 140-160 in-lb (15.8 - 18.1 N•m) 30-35 in-lb (3.4 - 4.0 N•m) 1 2
Page 41 - Sprayers Parts List
Sprayer 3A6564D 41 Sprayers Parts List Ref. Part Description Qty. 12 117501 SCREW, mach, slot hex wash hd 12 14 103413 PACKING, o-ring 1 22 17C541 COVER, front, painted 1 23 287900 SHIELD, motor, painted, includes 12 1 25 180131 BEARING, thrust 1 26 107434 BEARING, thrust 1 27 116073 WASHER, thrust ...
Page 42 - Control Box
Control Box 42 3A6564D Control Box Ref. Torque 140-160 in-lb (15.8 - 18.1 N•m) 30-35 in-lb (3.4 - 4.0 N•m) 37-43 ft-lb (50.2 - 58.3 N•m) 130-150 in-lb (14.7 - 16.9 N•m) 1 2 6 7 1 6 1 7 2
Page 43 - Control Box Parts List
Control Box 3A6564D 43 Control Box Parts List Ref. Part Description Qty. 2 117828 PACKING, o-ring 1 3 111457 PACKING, o-ring 1 4 111600 PIN, grooved 1 5 277364 GASKET, seat, valve 1 7 115498 SCREW, slot, hex, wash hd 1 11 116167 KNOB, potentiometer 1 12 117501 SCREW, mach, hex washer hd 4 15 15T811 ...
Page 44 - Compressor
Compressor 44 3A6564D Compressor Ref. Torque 60-85 in-lb (6.8 - 9.6 N•m) 95-100 in-lb (10.7 - 11.3N•m) 1 2 86 13 26 69 68 94 21 6 31 182 8982 141 184 185 91 92 93 85 90 95 31 96 146 95 106 107 170 105 112 169 86a 131 150 186 136 188 140 147 135 138 165 168 166 167 183 108 108 108 108 133 113 148 ti2...
Page 45 - Compressor Parts List
Compressor 3A6564D 45 Compressor Parts List Ref. Part Description Qty. 6 115494 SCREW, mach, Phil- lips 3 13 120643 GAUGE, pressure, panel mount, 1.5 1 21 127330 REGULATOR, air, 1/4 in. npt 1 26 CLAMP, wire 1 113491 Model 17E908 120143 All other models 31 117633 SCREW, slot hex wash hd 6 68 104641 F...
Page 46 - Wiring Diagrams
Wiring Diagrams 46 3A6564D Wiring Diagrams 120V or DISPLAY
Page 48 - Battery Replacement
Page 49 - Technical Specifications
Technical Specifications 3A6564D 49 Technical Specifications FinishPro II 595 PC Pro US Metric SprayerPower requirements 100/120V AC, 50/60 Hz, 15A, 1Ø 230V AC, 50/60 Hz, 10A, 1Ø Generator Minimum 4000 W Max tip size US / Europe / Asia/Australia 0.027 0.027 Max material output gpm (lpm) US...
Page 50 - Compliance; Radio Frequency Approvals; California Proposition 65
Compliance 50 3A6564D Compliance Radio Frequency Approvals Transmitter Frequency (all models): 2.4GHz Transmitter Power (all models): +8dBm NOTE: FCC/IC Notice (all models) Contains FCC ID: QOQBGM13P Contains IC: 5123A-BGM13P The enclosed device complies with Part 15 of the FCC Rules and with Indust...
Page 51 - Graco Standard Warranty
Graco Standard Warranty 3A6564D 51 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any...
Page 52 - Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 3A6564 Graco Headquarters: Minneapolis Int...