- Page 2 – Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD
- Page 3 – FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD
- Page 4 – Pump Models; ETL LISTED PUMPS
- Page 5 – Installation; General Information
- Page 6 – Mounting the Pump
- Page 7 – System Accessories; All Other Models
- Page 8 – Operation; Flush the Pump Before Using
- Page 9 – Maintenance
- Page 10 – Troubleshooting
- Page 11 – Pump Service; Disconnecting the Air Motor; Reconnecting the Air Motor
- Page 12 – Pump Parts
- Page 16 – Bung Mount Adjustable Length Pump, Carbon Steel Model
- Page 17 – Displacement Pump Service; Before You Start; Throat Packings
- Page 18 – Displacement Pump Parts; Stubby
- Page 25 – Adjustable Length, Carbon Steel, Rubber Packed
- Page 29 – Notes
- Page 37 – Dimensions
- Page 40 – The Graco Standard Warranty; Graco Information
1:1 RATIO
Fast–Flo
R
Pump
Air–operated piston transfer pump for low viscosity fluids. For professional use only.
Only models that are EX certified are approved for use in European explosive atmosphere
locations (see page 4).
1.2 MPa, 12.4 bar (180 psi) Maximum Air Input Pressure
1.2 MPa, 12.4 bar (180 psi) Maximum Fluid Working Pressure
For models that are certified, see page 4.
This symbol on the nameplate means the
product is listed by ETL.
(UL Standard No. 79, Standard for Power-Operated
Pumps for Petroleum Product Dispensing Systems).
Table of Contents
Symbols
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Models
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Service
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Parts
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Displacement Pump Service
17
. . . . . . . . . . . . . . . . . . . .
Displacement Pump Parts
18
. . . . . . . . . . . . . . . . . . . . . .
Accessories
35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data
38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty
40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Information
40
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instructions–Parts List
307427ZAA
EN
Stubby Pump
Bung-Mounted
Drum Length Pump
Bung-Mounted
Adjustable Length Pump
03761B
03761B
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Refer to page 4 for a list of pump models.
0359
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 307427 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. WARNING IN...
307427 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re-sult in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding the System on page 5. D If there is an...
4 307427 Pump Models ETL LISTED PUMPS The following pumps are ETL listed for light viscositypaints, lacquers, varnishes, thinners, solvents wheninstalled in accordance with NFPA (National FireProtection Association) Standards No. 30, Flammableand Combustible Liquids Code, and No. 33 SprayFinishing U...