  • Page 2 – PRODUCT IDENTIFICATION; D: Dedicated Downflow
  • Page 4 – PRODUCT DESIGN; Left; High Altitude Derate; Pressure
  • Page 5 – COMPONENT IDENTIFICATION
  • Page 6 – Cabinet Size
  • Page 7 – Part Number
  • Page 8 – Pa r t Num be r; AUXILIARY LIMIT SWITCHES
  • Page 9 – A large array of Amana; Coil Matches (for Goodman; PRODUCT
  • Page 10 – Filters can also be installed elsewhere in; Upflow Filters; Disposable Minimum Filter Area (in; Based on a 300 ft/min filter face velocity]; Permanent Minimum Filter Area (in; *Minimum filter area dictated by heating airflow requirement.; BOTTOM RETURN
  • Page 11 – FURNACE SPECIFICATIONS
  • Page 12 – BLOWER PERFORMANCE SPECIFICATIONS; BLOWER PERFORMANCE
  • Page 13 – MP
  • Page 14 – WIRING DIAGRAMS
Loading the manual

C

US

®

RT6612018 Rev. 5

April 2010

GMH95

40" 95% Gas Furnace

Refer to Service Manual

RS6610004 for installation, operation, and troubleshooting information.

All safety information must be followed as provided in the Service Manual.

Refer to the appropriate Parts Catalog for part number information.

Model numbers listed on page 3.

Copyright © 2007,

2009-2010

Goodman Manufacturing Company, L.P.

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANUAL

AL

AL

AL

AL

This manual is to be used by qualified, professionally trained HVAC technicians only.
Goodman does not assume any responsibility for property damage or personal
injury due to improper service procedures or services performed by an unqualified
person.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PRODUCT IDENTIFICATION; D: Dedicated Downflow

PRODUCT IDENTIFICATION 2 Minior Revision A 3 Description Air Flow Direction KBTUH AFUE Major Revision Maximum CFM @ 0.5" ESP 3: 1200 4: 1600 5: 2000 Cabinet Width The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use these num...

Page 4 - PRODUCT DESIGN; Left; High Altitude Derate; Pressure

4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chartfor details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe. R...

Page 5 - COMPONENT IDENTIFICATION

5 COMPONENT IDENTIFICATION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 Rollout Limit 8 Burners 9 Flame Sensor 10 Flue Pipe Connection / “Coupling” 11 Flue Pipe (Internal) 12 Pri...