Goodman GMS8 - Manual

Goodman GMS8

Goodman GMS8 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Table of Contents
  • Page 3 – WARNING
  • Page 4 – CARBON MONOXIDE POISONING HAZARD; WNER; III; RANSPORTATION; Keep this literature in a safe place for future reference.
  • Page 6 – CSA International; IV. LOCATION REQUIREMENTS AND CONSIDERATIONS; ENERAL; Combustion and Ventilation Air Requirements.
  • Page 7 – Suspended Furnace
  • Page 8 – National Fuel Gas Code NFPA 54/ANSI; (b) Equipment shall be installed in a location in which the; HERMOSTAT; HOT; Thermostat Influences; V. COMBUSTION AND VENTILATION AIR REQUIREMENTS; W A R N I N G
  • Page 9 – All Air from Outdoors:; Equipment Located in Confined Spaces All Air from Outdoors—; When communicating with the outdoors through vertical; Equipment Located in Confined Spaces All Air from Outdoors; . W h e n c o m m u n i c a t i n g w i t h t h e o u t d o o r s t h r o u g h; Equipment Located in Confined Spaces
  • Page 10 – Equipment Located in Confined Spaces All Air from Outdoors -; UPFLOW; M ODEL; When an existing furnace is removed from
  • Page 11 – Venting; Supply; Upflow Rotated Induced Draft Blower; Counterflow units; CATEGORY I FURNACES ONLY; AFUE; Typical Multiple Flue Clay Tile Chimney; HECKLIST
  • Page 14 – VIII. ELECTRICAL CONNECTIONS
  • Page 15 – CAUTION; Line voltage wiring; W A R NING; Integrated Ignition Control
  • Page 16 – Remote; Typical Field Wiring (24 VAC Control Circuit); Air Cleaner; Control Module; Optional
  • Page 17 – must; be in phase). Furnaces can be twinned to provide either; Furnace 1; Isolation Relay; IX. GAS SUPPLY AND PIPING; Natural Gas
  • Page 18 – * Firing rates m ay be lower than listed in table; ORIFICE SIZE; The input to the furnace must be checked AFTER reorificing.; not; derate the furnace by adjusting the manifold pressure to a
  • Page 19 – Natur al Gas Capacity of Pipe; General Furnace Layout; When the gas piping enters through the right side of the furnace
  • Page 20 – Never exceed specified pressures for testing. Higher; W ARNING; P r o p e r p r e s s u r e r e g u l a t i o n . ( Tw o - s ta g e r e g u l a t i o n i s
  • Page 21 – X. CIRCULATING AIR AND FILTERS; FURNACE INPUT; MINIMUM FILTER SIZES; XI. SEQUENCE OF OPERATION
  • Page 22 – INLET; Troubleshooting Chart
  • Page 23 – Inlet Gas Supply; With Power and Gas Off:; Measuring Inlet Gas Pressure (Alternate Method)
  • Page 24 – O PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE, THE GAS; Nat ural; Nat ural
  • Page 25 – Temperature Rise Measurement; OFF; Temperature; air circulator blower fan; Adjustment Switches; XIII. OPERATIONAL CHECKS
  • Page 26 – Burner Flame
  • Page 27 – Internal Filter Removal
  • Page 28 – “Operational; XVII. BEFORE LEAVING AN INSTALLATION
  • Page 29 – FLASH
  • Page 30 – Applies to
  • Page 31 – Wiring Diagram for
  • Page 32 – Quality Makes the Difference!; There’s No Better Quality.
Loading the manual

These furnaces comply with requirements
embodied in the American National Standard
/ N a t i o n a l St a n d a r d o f C a n a d a A N S I
Z 2 1 . 4 7 · C S A - 2 . 3 G a s F i r e d C e n t r a l
Furnaces.

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to know the product better than the customer. This includes all

safety precautions and related items.

Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all

safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous

than when the unit is in operation.

Remember, it is

your

responsibility to install the product safely and to know it well enough to be able to instruct a

customer in its safe use.

Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good

safety practices...follow them.

The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there

is a direct conflict between existing practices and the content of this manual, the precautions listed here take

precedence.

*NOTE: Please contact your distributor or our website for the applicable product data book referred to in this manual.

C

US

®

(CATEGORY 1)

IO-242C

05/05

©

2005 Goodman Manufacturing Company, L.P.

INSTALLATION & OPERATING

INSTRUCTIONS for

GMS8, GDS8 and GHS8

GAS FIRED WARM AIR FURNACE

SINGLE STAGE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents

2 IO-242C 05/05 Table of Contents I. Warnings .......................................................................................................................................................................... 3 T O T HE O WNER ....................................................................

Page 3 - WARNING

3 IO-242C 05/05 Table of Contents XII. Start-up Procedure and Adjustment ......................................................................................................................... 21 F URNACE O PERATION .....................................................................................

Page 4 - CARBON MONOXIDE POISONING HAZARD; WNER; III; RANSPORTATION; Keep this literature in a safe place for future reference.

4 IO-242C 05/05 WARNING S HOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY. CARBON MONOXIDE POISONING HAZARD - Special Warning for Installation of Furnace or Air Handling U nits inEnclos...