Giant GP8155-R - Manual
Giant GP8155-R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION INSTRUCTIONS
- Page 3 – Specifications; REQUIREMENTS; RPM GPM; GP8155-R PUMP REPAIR INSTRUCTIONS
- Page 4 – To Dismantle Crankcase Gear
- Page 6 – GP8155-R TOOL LIST AND TORQUE SPECIFICATIONS; GP8155-R TROUBLESHOOTING; Valve Inspection and Repair; To Check Seals and Plunger Pipe
Contents:
Installation Instructions:
page 2
Pump Specifications:
page 3
Exploded View/Parts List:
pages 4-5
Repair Kits/Tool List:/Torque Specifications
page 6
Troubleshooting Chart:
page 6
Repair Instructions:
pages 7-10
Dimensions:
page 11
Warranty Information
back page
Triplex Ceramic
Plunger Pump
Model Manual
MODEL
GP8155-R
WITH INTEGRAL GEARBOX 180
o
REVERSE
Updated 4/08
4/08 GP8155-R.PMD
GIANT INDUSTRIES, INC.
900 N. Westwood Ave.
Toledo, Ohio 43607
(419) 531-4600
FAX (419) 531-6836
www.giantpumps.com
Copyright 2008 Giant Industries, Inc.
GIANT INDUSTRIES LIMITED WARRANTY
Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in
workmanship and material as follows:
1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never
fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable
pressure washers and in car wash applications, are warranted for five years from the dateof shipment for
all pumps used in NON-SALINE, clean water applications.
2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps.
3. Six (6) months from the date of shipment for all rebuilt pumps.
4. Ninety (90) days from the date of shipment for all Giant accessories.
This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation
shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will
void the warranty:
1. Defects caused by negligence or fault of the buyer or third party.
2. Normal wear and tear to standard wear parts.
3. Use of repair parts other than those manufactured or authorized by Giant.
4. Improper use of the product as a component part.
5. Changes or modifications made by the customer or third party.
6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations
Manuals provided by Giant Industries, Inc.
Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products
returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of
material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior
to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-
6836 to obtain an R.G.A. number.
Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and
the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR INDIRECTLY ARISING FROM THE SALE OR USE
OF THIS PRODUCT.
THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR REPRESENTATION,
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND
EXCLUDED BY THE MANUFACTURER.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Installation of the Giant Industries, Inc., pump is not acomplicated procedure, but there are some basic stepscommon to all pumps. The following information is to beconsidered as a general outline for installation. If youhave unique requirements, please contact Giant Indus-tries, Inc. or your local ...
U.S. (Metric) Volume ............................................................. Up to 74.8 GPM ...... (283 LPM)Discharge Pressure ......................................... Up to 2900 PSI ........ (200 bar)Speed ............................................................... Up to 580 RPM ....... ...
EXPLODED VIEW - GP8155-R 4 GP8155-R PUMP REPAIR INSTRUCTIONS 12) Remove the connecting rod screws (24). Connecting rods are marked 1 to 3 for identification. Do not rotate connecting rodhalves or interchange them. When re-assembling,the connecting rod must be fitted in their exactoriginal position o...