Page 2 - INSTALLATION INSTRUCTIONS; IMPORTANT OPERATING CONDITIONS; Crankcase oil should be changed after the
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. The use of adampener with Giant Industries, Inc. pumps isoptional, although recommended by GiantIndustries, Inc. to further reduce system pulsa-tion. ...
Page 3 - Specifications; *15 PSI inlet pressure required; PULLEY INFORMATION; Select GPM required, then select appropriate; HORSEPOWER INFORMATION; REQUIREMENTS
3 Specifications Model P217A-3100/5100 Consult the factory for special requirements that must be met if the pump isto operate beyond one or more of the limits specified above. U.S. (Metric) 1750 RPM + Ratings ......................................................... 1.8 GPM @ 2000 PSI ...... (6.8 LP...
Page 6 - * Positive inlet pressure required
6 Specifications Model P220A-3100/5100 Consult the factory for special requirements that must be met if the pump isto operate beyond one or more of the limits specified above. PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.75 5.25 1150 3.1 1.7 2.6 3.2 3.6 4.3 7.75 6.5...
Page 7 - The rating shown are the power; *Intermittent duty only; Positive inlet pressure required
7 NOTE: In order to drive the pump from the side opposite the present shaft extension, simplyremove the valve casing from the crankcase and rotate the pumps 180 degrees to thedesired position. Be certain to rotate the seal case (item #20) as well, so that the weepholes are down at the six o'clock po...
Page 11 - Plunger Packing Kit; Position; Valve Assembly Kit
11 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301-0100 Dipstick 1 3 08302 Crankcase Plug Cover 1 3A 07190-0100 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185-0100 Oil Drain Plug with seal 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.S. 4 7 08303 Bearing Cover I...
Page 13 - Disassembly sequence of the; back; Before you begin, drain the oil from the crankcase.; Pump Mounting Selection Guide; - 24 mm Tapered H Bushing
13 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). To remove the crankshaft (13),remove the bearing cover (7) and sight glass (8). Using a rubber m...
Page 14 - PUMP SYSTEM MALFUNCTION
14 Preventative Maintenance Check-List & Recommended Spare Parts List Check Daily Weekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change X X Seal Spare Parts (1 kit/pump) X (See page 11 ...
Page 16 - GIANT INDUSTRIES LIMITED WARRANTY
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free fromdefects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifoldswill never fail, period. If they ever fai...