Page 2 - Technical Support; Fax; Technical Support Hours:; any accompanying doc u men ta tion without prior written notice.; x2 DPKVM Switch; is a trademark of Gefen LLC; ASKING FOR ASSISTANCE
Technical Support : Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday. Write To: Gefen LLCc/o Customer Service20600 Nordhoff St Chatsworth, CA 91311 [email protected] Notice Gefen, LLC reserves the right to make cha...
Page 3 - CONTENTS
CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 5 Panel Descriptions 6 Connecting the 2x2 DPKVM Switch 7 Operating the 2x2 DPKVM Switch 8 RMT-2IR Remote Control Description 9 RMT-21IR Remote Installation 10 Infared (IR) Code Channel Confi guration 11 RS-232 Serial Control Interfa...
Page 4 - INTRODUCTION; Gefen
1 INTRODUCTION Congratulations on your purchase of the 2x2 DPKVM Switch. Your complete satisfaction is very important to us. Gefen Gefen is a unique product line catering to the growing needs for innovative home theater solutions. We specialize in total integration for your home theater, while also ...
Page 5 - Dual Link resolutions up to 2560 x 1600 are supported.; OPERATION NOTES
READ THESE NOTES BEFORE INSTALLING OR OPERATING THE 2X2 DPKVM SWITCH • The 2x2 DPKVM Switch supports Pass-through EDID. The Switch will use the EDID from the currently active input. • Dual Link resolutions up to 2560 x 1600 are supported. OPERATION NOTES 2
Page 6 - FEATURES; Features
3 FEATURES Features • Switches two high-defi nition displays between two DisplayPort-equipped computers with audio/video and USB peripherals • Supports up to 1920 x 1200 with a single link monitor • Supports up to 2560 x 1600 with dual link monitor • Supports RGB and YCbCr color spaces • Rack mounta...
Page 7 - PANEL LAYOUT; Front Panel
4 PANEL LAYOUT Front Panel Back Panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Page 8 - PANEL DESCRIPTIONS
5 PANEL DESCRIPTIONS 1 I/R Receiver Receives I/R signal from the handheld Infrared remote control unit included with the 2x2 DVI KVM Switch. 2 LED Input Status Indicator 1 & 2 This currently selected source input will be indicated with an active LED. 3 Input Selector Button Pressing this button ...
Page 9 - CONNECTING THE 2X2 DPKVM SWITCH; Connecting Source Devices to the 2x2 DPKVM Switch; DISPLAYPORT CABLE
CONNECTING THE 2X2 DPKVM SWITCH Connecting Source Devices to the 2x2 DPKVM Switch 1. Connect up to two DisplayPort source devices to the DisplayPort inputs on the 2x2 DPKVM Switch using the included DisplayPort cables. 2. Connect up to two audio sources to the 3.5mm analog audio mini-jack inputs usi...
Page 10 - OPERATING THE 2X2 DPKVM SWITCH; Front Panel Input Selector
How to Operate the 2x2 DPKVM Switch Switching can be accomplished via the front panel selector button, infrared (IR) remote control, or the RS-232 communications port. Additional switching options can be found on page 12 1 For information on switching via the front panel selector button, please see ...
Page 11 - RMT-2IR REMOTE CONTROL DESCRIPTION
RMT-2IR REMOTE CONTROL DESCRIPTION 1 Pressing this button will select Input 1 as the source. All devices connected to the input ports labeled 1 will be selected and output. 2 Pressing this button will select Input 2 as the source. All devices connected to the input ports labeled 2 will be selected a...
Page 12 - RMT-2IR REMOTE INSTALLATION; Risk of explosion if battery is replaced by an incorrect; Empty Battery Slot
RMT-2IR REMOTE INSTALLATION 9 To use the RMT-2IR remote, remove the battery cover on the back of the remote to reveal the battery compartment. Insert the included battery into the open battery slot. The positive (+) side should be facing up. Ensure that both DIP (Dual Inline Package) switches are in...
Page 13 - How to Resolve IR Code Confl icts; Picture of the opened rear battery; x2 DPKVM Switch DIP Switch Settings
INFRARED (IR) CODE CHANNEL CONFIGURATION How to Resolve IR Code Confl icts In the event that IR commands from other remote controls confl ict with the supplied RMT-2IR remote control, changing the remote channel will alleviate this issue. The RMT-2IR remote control and the 2x2 DPKVM Switch both have...
Page 14 - RS-232 SERIAL CONTROL INTERFACE; The 2x2 DPKVM Switch can accept commands through the RS-232 serial; Switching/Routing Binary Table
RS-232 SERIAL CONTROL INTERFACE What features are available via the RS-232 serial communications port? The 2x2 DPKVM Switch can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are: • Switching of inputs. How do I use these ...
Page 15 - ADDITIONAL SWITCHING OPTIONS; Not Used
ADDITIONAL SWITCHING OPTIONS The underside of the 2x2 DPKVM Switch features a DIP switch bank that is used to confi gure additional features. DIP switch 3 is used to control the function of Contact Closure-type remote controls on the rear panel. 1 2 3 4 This port can be confi gured to accept additio...
Page 16 - SPECIFICATIONS
13 SPECIFICATIONS Input Connector....................................................(4) DisplayPort (from computers) Output Connector...........................................................(2) DisplayPort (to display) Input Connector..........................................(2) USB 2.0 Type “B” ...
Page 17 - WARRANTY; Proof of sale may be required in order to claim warranty.; PRODUCT REGISTRATION; under the Support section of the Gefen Web site.
14 WARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is notifi ed within two (2) years from the date of shipment, Gefen will, at its option, repair or replace the equipment, provided that th...
Page 19 - Pb
Rev A1 Pb 20600 Nordhoff St., Chatsworth CA 91311 1-800-545-6900 818-772-9100 fax: 818-772-9120 www.gefen.com [email protected] This product uses UL listed power supplies.