Page 2 - ES42 Series Edge Switches; www GarrettCom com; Magnum; Trademarks; are trademarks and; Personal Hub; is a registered trademark of GarrettCom, Inc.
ES42 Series Edge Switches Installation and User Guide (05/05) i www GarrettCom com . . Magnum ™ ES42 Series Edge Switch Installation and User Guide Part #: 84-00141 Rev. A (02/05) Trademarks GarrettCom, Magnum , Link-Loss-Learn, S-Ring, Convenient Switch, Edge Switch are trademarks and Personal Hub ...
Page 3 - Federal Communications Commission; whatever measures may be required to correct the interference.
ES42 Series Edge Switches Installation and User Guide (05/05) ii www GarrettCom com . . Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with t...
Page 4 - Contacting GarrettCom, Inc
ES42 Series Edge Switches Installation and User Guide (05/05) iii www GarrettCom com . . Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 ...
Page 5 - TABLE OF CONTENTS
ES42 Series Edge Switches Installation and User Guide (05/05) iv www GarrettCom com . . TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ..............................................................
Page 7 - Initial release of this user manual for ES42 Edge Switches
ES42 Series Edge Switches Installation and User Guide (05/05) vi www GarrettCom com . . 5.4 Shipping and Packaging Information................................................. 67 APPENDIX A: WARRANTY INFORMATION ......................................... 69 Revisions Rev A 05/05: Minor updates on MDI...
Page 8 - Technical Specifications; Ports Performance; Packet-Processing Between Domains
ES42 Series Edge Switches Installation and User Guide (05/05) 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 1...
Page 9 - Path Delay Value; : 50 BT on all ports; Factory default is activated on port 1 and 2; Maximum Ethernet Segment (or Domain) Lengths
ES42 Series Edge Switches Installation and User Guide (05/05) Address buffer age-out time: 300 sec. Packet buffers memory: 128KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5 µ s 10 to 100Mbps: 15 µ s Path Delay Value : 50 BT on all ports LLL(Link-Loss-Lea...
Page 10 - Operating Environment; ES42: 32; Storage Temperature; Conformal Coating (optional) for humidity protection
ES42 Series Edge Switches Installation and User Guide (05/05) Operating Environment ES42: 32 º F to 104 º F (0 º C to 40 º C) ES42H: -13 º F to 140 º F (-25 º C to 60 º C) Long term per agency tests (UL). -40 º F to 149 º F (-40 º C to 85 º C) Short term per IEC Type tests. ES42P: -40 º F to 167 º F...
Page 11 - ALARM RELAY Terminal Block, H and P models only, two screw terminals:
ES42 Series Edge Switches Installation and User Guide (05/05) Packaging: Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit: 3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm) Weight: all models: 9.5 oz. (285g); Power supply, –d, and i: 5.8 oz (165g) –Hd, and Hi: 5.8 oz (165...
Page 12 - POWER SUPPLY; with a Listed 5 A DC fuse in the supply circuit.
ES42 Series Edge Switches Installation and User Guide (05/05) POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and su...
Page 13 - . Input: 240vac at 50Hz with IEC 320 connector for the user
ES42 Series Edge Switches Installation and User Guide (05/05) International (-i) models . Input: 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord. Output:12vdc, 1Amps Factory Floor Models (H) Ratings (-25 to 60°C) North America (-Hd) models. Hardened, factory floor temperatu...
Page 14 - Power Consumption
ES42 Series Edge Switches Installation and User Guide (05/05) Direct DC POWER SUPPLY : built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range 8.0 to 15V DC), 24V DC internal (range 10 to 36V DC), -48V DC internal (range 30 to 60V DC),+ , -, ground. Note: DUAL-SRC-24KIT...
Page 15 - POWER: Steady ON when power applied
ES42 Series Edge Switches Installation and User Guide (05/05) Port Connectors: RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX). They are shielded 8-pin female connectors for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable. One Fiber optic port: On the ES42 Series it is 100B...
Page 16 - Mounting options; Emissions meets FCC Part 15 Class A.
ES42 Series Edge Switches Installation and User Guide (05/05) Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Depth: 6.0”, width: 17” Height: 2....
Page 17 - Summary of models and descriptions:; Note: The ES42 model # consists of the base unit type and the power
ES42 Series Edge Switches Installation and User Guide (05/05) 1.2 Summary of models and descriptions: Note: The ES42 model # consists of the base unit type and the power input. Insert S for sgl-mode , the fiber flavor (2ff) and the power input. H- hardened, P-premium, R- Din –Rail MC2, d- domestic, ...
Page 18 - Accessories
ES42 Series Edge Switches Installation and User Guide (05/05) ES42PR-2ff-24VDC = Same as ES42P-24VDC model, but includes DIN-RAIL-MC2 mounting opt. ES42P-2ff-48VDC = Same as ES42P-24VDC model, except -48VDC input replaces 24VDC. Note: For dual source 24V power input to DC jack, order Model# DUAL-SRC...
Page 19 - typical applications.; Inspecting the Package and the Product; This package should contain:
ES42 Series Edge Switches Installation and User Guide (05/05) 2.0 INTRODUCTION This section describes ES42 Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this pro...
Page 20 - Product Description; six port
ES42 Series Edge Switches Installation and User Guide (05/05) Remove the Magnum ES42 Series Edge Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you ...
Page 22 - Redundant LANs at economical cost.; The Magnum ES42 regular-package units
ES42 Series Edge Switches Installation and User Guide (05/05) pass the reconfiguration signal down the line to other ring switches in the redundant structure for faster recovery. Magnum Edge switches, combined with other Magnum managed switches, running STP/RSTP or S-Ring, can often provide high ava...
Page 23 - YELLOW
ES42 Series Edge Switches Installation and User Guide (05/05) A robust metal case with convection cooling is featured. Metal mounting clips are included, and rack-mount tray options are available. 1 0 / 1 0 0 1 2 V D C 1 A M P 1 0 F O R 1 0 0 A O R L K / A C T L K / A C T P W R 1 2 3 4 5 6 PORT PORT...
Page 25 - ORANGE
ES42 Series Edge Switches Installation and User Guide (05/05) heavy duty industrial jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25 to 60C is for industrial use. No intern...
Page 26 - RED; Fig
ES42 Series Edge Switches Installation and User Guide (05/05) AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –25°C to + 85°C. The RED labeled Magnum ES42P Premium-rated units are for temperatur...
Page 27 - All the premium and hardened models also come along with hardware
ES42 Series Edge Switches Installation and User Guide (05/05) The ES42P series (as shown in Fig. 2.2f & g) are premium rated units suitable for temperature un-controlled outdoor applications. Specially designed with premium-grade extended temperature components, the ES42P units use similar therm...
Page 28 - solutions in a very small footprint.
ES42 Series Edge Switches Installation and User Guide (05/05) auto-cross (MDIX) operation under auto-negotiation mode. The ES42 series provides switching among four 10/100 auto-negotiating copper ports and two 100Mb fiber ports which may be SC, ST, MTRJ or LC multi-mode or single-mode. The ES42’s br...
Page 29 - terminal is provided on the rear of the unit.; Frame Buffering and Latency
ES42 Series Edge Switches Installation and User Guide (05/05) There is a power (PWR) LED to indicate that the unit is turned ON. The fiber ports on the ES42 Edge switches are multi-mode or single-mode with an SC, ST or small form factor connector (MTRJ multi mode or LC single-mode). The external DC ...
Page 30 - when the traffic load is greatest.
ES42 Series Edge Switches Installation and User Guide (05/05) network. The "cut-through" technique permits collision fragment frames, which are a result of late collisions, to be forwarded--which add to the network traffic. There is no way to filter frames with a bad CRC (the entire frame mu...
Page 32 - Features and Benefits
ES42 Series Edge Switches Installation and User Guide (05/05) The latency (the time the frame spends in the Switch before it is sent along or forwarded to its destination) of the ES42 Series Edge Switches varies with the port-speed types. The length of the frame is a variable as it is with all store...
Page 33 - Choice of one or two100Mb Fiber option, more efficient; Designed as a; Two sets of LEDs for viewing status from any angle.; ES42 Series have a robust design and
ES42 Series Edge Switches Installation and User Guide (05/05) Choice of one or two100Mb Fiber option, more efficient Designed as a multi-purpose media Edge Switch, the 100Mb fiber port allows the user to convert the media from copper to fiber and the other RJ-45 port can be used as diagnostic port o...
Page 34 - C for DC models and; Efficient Compact design, for all purpose convenient mounting; All the; Hardware operated Alarm terminal block for ES42H and ES42P
ES42 Series Edge Switches Installation and User Guide (05/05) 27 www GarrettCom com . . Qualified to use for temperature un-controlled “outdoor” application The Magnum ES42P Premium rated versions of Edge Switches have an ambient temperature rating between –40 º C to +75 º C for DC models and qualif...
Page 35 - Applications for ES42 Series Edge Switches
ES42 Series Edge Switches Installation and User Guide (05/05) Link-Loss-Learn feature for faster recovery in redundant managed network The LLL feature qualifies the Edge switches to actively work along with redundant network structure as a client switch and allow a faster recovery during ring break....
Page 36 - economical solution for faster recovery, during the ring break.
ES42 Series Edge Switches Installation and User Guide (05/05) requirements via providing edge support and reliability to the managed redundant network. The Dual-Speed and Dual-media functions support a mixed environment of 10 Mbps and 100Mbps users with copper and fiber media. The switched full dupl...
Page 37 - Example1. Supermarket application for ES42; In this example, the; PWR
ES42 Series Edge Switches llation and User Guide (05/05) Insta 30 www GarrettCom com . . Example1. Supermarket application for ES42 In this example, the supermarket required a Data Mining function to store all the transaction with an ongoing demand to expand the network. 2 4 6 8 1 3 5 7 PWR ALARM CO...
Page 38 - single–mode fiber while securing the LAN from EMI and wire tapping.
ES42 Series Edge Switches Installation and User Guide (05/05) This need can be easily met using the economical Magnum ES42 Edge Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire tapp...
Page 40 - A L A R; iMa c
ES42 Series Edge Switches Installation and User Guide (05/05) www GarrettCom com . . 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 2 2 24 AC TF/HAC TF/H AC TF/HAC TF/H AC TF/HAC TF/H AC TF/HAC TF/H 2 4 6 8 1 3 5 7 G a r r e t t C o m M a g n u m 6 K 1 6 V PWR CONS OLE PORT G a r r e t t C...
Page 41 - In this example, the Magnum ES42P premium Edge Switches are
ES42 Series Edge Switches Installation and User Guide (05/05) Example 3: ES42P: In this example, the Magnum ES42P premium Edge Switches are deployed to serve as a secure corporate or transportation surveillance system. CCTV cameras may be spread out over many miles in temperature un-controlled locat...
Page 42 - effective solution, make an ideal choice in outdoor environments.
ES42 Series Edge Switches Installation and User Guide (05/05) 1 3 5 7 9 11 13 1 5 17 19 21 23 2 4 6 8 10 1 2 1 4 1 6 18 20 22 24 ACTF/HACTF/H AC TF/HAC TF/H A CTF/HA CTF/H ACTF/HACTF/H 2 4 6 8 1 3 5 7 1 0 / 1 0 0 1 2 V D C 1 A M P 1 0 F O R 1 0 0 A O R L K / A C T L K / A C T P W R 1 2 3 4 5 6 PORT ...
Page 43 - power supply options and media connection.; Secure attachment of; Locating the Edge Switch Unit; All the ES42 Series Switches operate in
ES42 Series Edge Switches Installation and User Guide (05/05) 3.0 INSTALLATION This section describes the installation of the Magnum ES42 Series Edge Switches, including location, mountings, power supply options and media connection. Secure attachment of clips for panel - 3.1 Locating the Edge Switc...
Page 44 - mounting in any orientation.
ES42 Series Edge Switches Installation and User Guide (05/05) The compact and lightweight design of the Magnum ES42 Series allows it to be easily installed in almost any location. A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet, or for securing the un...
Page 45 - MC14-TRAY for Rack Mounting of ES42 Series Switches
ES42 Series Edge Switches Installation and User Guide (05/05) 3.2 MC14-TRAY for Rack Mounting of ES42 Series Switches For 19” rack-mounting of Magnum ES42 series Edge Switches, a rack-mount tray is available, the MC14-TRAY. The Edge Switches are mounted with the DC power jack in the back, with the f...
Page 46 - In a typical
ES42 Series Edge Switches Installation and User Guide (05/05) Media Edges may be placed on a tray, up to a maximum of 8 units. (The mounting spaces of the MC14-TRAY are specific to the Magnum products and will not permit other models to be properly mounted). In a typical installation, the MC14-TRAY,...
Page 47 - input for use worldwide.
ES42 Series Edge Switches Installation and User Guide (05/05) has two groups of eight units per power supply. The power supplies have auto-ranging AC input for use worldwide. The side-view < here is an example of an installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few ES42, a...
Page 48 - A Magnum ES42H is; The Magnum ES42 models with “HR” have 24VDC power, and have the DIN-
ES42 Series Edge Switches Installation and User Guide (05/05) 3.4 DIN-Rail mounting option The Magnum ES42H and ES42P Edge Switches, designed for use in “Factory Floor” Industrial Ethernet environments, are available for DIN-Rail mounting in an enclosure having DIN Rails A Magnum ES42H is shown alon...
Page 49 - The 12V DC power input jack has a plug of 2.5mm,
ES42 Series Edge Switches Installation and User Guide (05/05) 3.5 Power Requirements, Power Supply Types for ES42 Series Switches Magnum ES42 Series Switches are power-efficient and can work with an external AC power supply. Magnum ES42 Series require a nominal 12VDC input version. The extended temp...
Page 50 - to deploy in uncontrolled temperature environments.
ES42 Series Edge Switches Installation and User Guide (05/05) withstand higher temperature environments, and provide the DC power choices to the user to deploy in uncontrolled temperature environments. The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9...
Page 52 - Note: The ES42H or P models with 24VDC
ES42 Series Edge Switches Installation and User Guide (05/05) Note: The ES42H or P models with 24VDC support the Dual Source 24V input option. An external Dual-SRC-24KIT (SHOWN AT RIGHT…and sold separately, or a customer- supplied equivalent) can be used to input 24VDC power to the ES4H or P unit vi...
Page 53 - GND; : Terminal for “earth” or ground wire connection to the ES42H chassis; Input Voltage
ES42 Series Edge Switches Installation and User Guide (05/05) 3.6 continued, DC Power Terminals : “+”, “-”, gnd GND : Terminal for “earth” or ground wire connection to the ES42H chassis Input Voltage : 12VDC 24VDC -48VDC Input current : 12VDC (8-15VDC) Alarm Contact Terminal (12V) (8-15VDC) 24VDC (1...
Page 55 - will connect to the post labeled “+ve” and the rest to the “-ve”.
ES42 Series Edge Switches Installation and User Guide (05/05) the DC leads to the ES42H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) optional; it connects to the ES42H chassis. Ensure that each lead is securely tightened from the top, as shown on above picture wit...
Page 56 - Media; 00BASE-TX RJ-45
ES42 Series Edge Switches Installation and User Guide (05/05) ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE- FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling c...
Page 57 - shielded twisted pair cables.
ES42 Series Edge Switches Installation and User Guide (05/05) 3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded ...
Page 58 - tips of the fiber connectors. Save these dust caps for future use.
ES42 Series Edge Switches Installation and User Guide (05/05) 51 www GarrettCom com . . 3.8.2 Connecting Fiber Optic ST-type, “twist-lock” The following procedure applies to installations using ST-type fiber connectors. This procedure applies to ports using multi-mode ST fiber connectors. 1. Before ...
Page 59 - Single-Mode Fiber Optic
ES42 Series Edge Switches Installation and User Guide (05/05) 3.8.3 Connecting Fiber Optic SC-type, "Snap-In" The following procedure applies to installations using SC-type fiber connectors, i.e., using multi-mode SC and SC single-mode. While connecting fiber media to SC connectors, simply s...
Page 60 - Budget; where P
ES42 Series Edge Switches Installation and User Guide (05/05) 3.8.5 Power Budget Calculations for ES42 Series, Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using M...
Page 62 - only; if the following; Connections to NICs which support Auto-Negotiation, RJ-45 ports
ES42 Series Edge Switches Installation and User Guide (05/05) * Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied: • The 100Mb fiber segment must opera...
Page 63 - The Magnum ES42 Series Edge Switches provide SIX switched ports
ES42 Series Edge Switches Installation and User Guide (05/05) 4.0 OPERATION 4.1 Dual-Speed Functionality, and Switching The Magnum ES42 Series Edge Switches provide SIX switched ports with combination of fiber and copper or copper only. The architecture supports a dual speed switching environment, w...
Page 64 - Switching, Filtering and Forwarding
ES42 Series Edge Switches Installation and User Guide (05/05) devices. There is no software configuring to be done at installation or for maintenance, even for the LLL ports. The internal functions of both are described below. Switching, Filtering and Forwarding Each time a packet arrives on one of ...
Page 65 - When an RJ-45 cable connection is made, and each time LINK is enabled,
ES42 Series Edge Switches Installation and User Guide (05/05) nodes are added or removed or moved from one segment to another, the ES42- Series switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addres...
Page 67 - LED Description; Illuminates GREEN to indicate power applied.
ES42 Series Edge Switches Installation and User Guide (05/05) 4.3 Dual LEDs, Front-panel and side-panel (Magnum ES42 Series) LED Description PWR Illuminates GREEN to indicate power applied. LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn off in the event conne...
Page 70 - for assistance or contact GarrettCom Customer Support.; Before Calling for Assistance; connected and the cables/wires have not been crimped or in some way
ES42 Series Edge Switches Installation and User Guide (05/05) procedures described in this section or if the Magnum ES42 Series 10/100 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support. 5....
Page 71 - Make sure that an AC power cord is properly attached to each Magnum
ES42 Series Edge Switches Installation and User Guide (05/05) 3. If the fiber port does not link up while connecting to other device, do a quick Loop test to test the fiber transceiver is functional or not. Use a short patch cable of fiber and connect one end of cable to transmit and other end of re...
Page 72 - corrected, the Magnum ES42 Series Switch and its associated; When Calling for Assistance; Please be prepared to provide the following information.
ES42 Series Edge Switches Installation and User Guide (05/05) corrected, the Magnum ES42 Series Switch and its associated cables are functioning properly. 6. If the problem continues after completing Step 5 above, contact your supplier of the Magnum ES42 Series 10/100 Mb/s Switch unit or if unknown,...
Page 73 - procedures should all be noted in this record.
ES42 Series Edge Switches Installation and User Guide (05/05) 2. An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. 3. It is useful to include other network equipment models and related hardware, inc...
Page 75 - GarrettCom, the unit will be returned as:; Shipping and Packaging Information
ES42 Series Edge Switches Installation and User Guide (05/05) with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found. Garret...
Page 76 - This material may cause electro-static shock damage to the unit.; outside of the shipping container.; Westinghouse
ES42 Series Edge Switches Installation and User Guide (05/05) or bag for shipping protection. (You may retain all connectors and this Installation Guide.) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the un...
Page 77 - APPENDIX A: WARRANTY INFORMATION; provided that the product is returned pre-paid to GarrettCom.
ES42 Series Edge Switches Installation and User Guide (05/05) APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom ...