Page 2 - IPS42 Internal Power Supply; Magnum; Trademarks; is a registered trademark and; Converter Switch; Ethernet is a trademark of Xerox Corporation
IPS42 Internal Power Supply Installation and User Guide (11/09) i www GarrettCom com . . Magnum ™ IPS42 Internal Power Supply for Edge Switch Family Installation and User Guide Part #: 84-00181Z Rev. B Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link...
Page 3 - The Magnum IPS42 Series Internal Power Supply for Edge Switches
IPS42 Internal Power Supply Installation and User Guide (11/09) ii www GarrettCom com . . Important: The Magnum IPS42 Series Internal Power Supply for Edge Switches contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems ...
Page 4 - Federal Communications Commission; whatever measures may be required to correct the interference.
IPS42 Internal Power Supply Installation and User Guide (11/09) iii www GarrettCom com . . Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance wit...
Page 5 - Electrical Safety requirements:
IPS42 Internal Power Supply Installation and User Guide (11/09) iv www GarrettCom com . . Electrical Safety requirements: 1. This product is to be installed Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like). 2. 48VDC products shall be installed with a readi...
Page 6 - Contacting GarrettCom, Inc
IPS42 Internal Power Supply Installation and User Guide (11/09) v www GarrettCom com . . Contacting GarrettCom, Inc Please use the mailing address, phone, fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Web...
Page 7 - TABLE OF CONTENTS; SPECIFICATIONS
IPS42 Internal Power Supply Installation and User Guide (11/09) vi www GarrettCom com . . TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ......................................................
Page 8 - APPENDIX A: WARRANTY INFORMATION
IPS42 Internal Power Supply Installation and User Guide (11/09) vii www GarrettCom com . . 4.2 When Calling for Assistance ............................................................. 24 4.3 Return Material Authorization (RMA) Procedure ............................. 25 4.4 Shipping and Pa...
Page 9 - Technical Specifications; Power Consumption: 10 Watts typical for a 4+2 port fiber model; DC Power Supplies for Dual Source DC:
IPS42 Internal Power Supply Installation and User Guide (11/09) 1 www GarrettCom com . . 1.0 SPECIFICATIONS 1.1 Technical Specifications AC/DC Power Supply (Model IPS42-AC/DC): Power Input: DC: 100-250 VDC AC: 100-250 VAC, 47 to 63 Hz, auto ranging Surge Rating: IEC 61000-4-3, Class 3/4 (4KV for DC)...
Page 10 - AC Power Connector: standard IEC 320 male, recessed; Mechanical Specifications:; Dimensions of the IPS42 unit:; Operating Environment:
IPS42 Internal Power Supply Installation and User Guide (11/09) 2 www GarrettCom com . . AC Power Supply (Model IPS42-AC) AC Power Connector: standard IEC 320 male, recessed Power Input: 100-250 VAC, 47 to 63 Hz, auto ranging Power Consumption: 10 Watts typical for a 4+2 port fiber model Mechanical ...
Page 11 - ALARM RELAY Terminal Block, four screw terminals:; Metal mounting clips for panel mounting: included
IPS42 Internal Power Supply Installation and User Guide (11/09) 3 www GarrettCom com . . Cooling Method: All IPS42 models feature convection cooling for temperature un-controlled locations. All models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outs...
Page 12 - Agency Approvals and Standards Compliance:; Emissions meets FCC Part 15 Class A; IEC 61850 EMC and Operating Conditions Class C Power Substations
IPS42 Internal Power Supply Installation and User Guide (11/09) 4 www GarrettCom com . . Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A IEC 61850 EMC and Operating Conditions Class C Power Substations IEEE 1613 Env. Standard for Electric...
Page 13 - Summary of models and descriptions for IPS42 Series:; Internal Power Supply chassis for use with any ES42H or ES42P
IPS42 Internal Power Supply Installation and User Guide (11/09) 5 www GarrettCom com . . 1.2 Summary of models and descriptions for IPS42 Series: IPS42-AC/DC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external...
Page 14 - Internal Power Supply chassis for use with any
IPS42 Internal Power Supply Installation and User Guide (11/09) 6 www GarrettCom com . . IPS42-48VDC-DualSRC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Rated 44 ...
Page 15 - Conformal Coating
IPS42 Internal Power Supply Installation and User Guide (11/09) 7 www GarrettCom com . . IPS42-AC: Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch. Requires simultaneous ordering of an ES42 (without external power supply) as a separate line item. Standard worldwide A...
Page 16 - Inspecting the Package and the Product; This package should contain:
IPS42 Internal Power Supply Installation and User Guide (11/09) 8 www GarrettCom com . . 2.0 INTRODUCTION 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage that you believe occur...
Page 17 - Description
IPS42 Internal Power Supply Installation and User Guide (11/09) 9 www GarrettCom com . . Remove the Magnum IPS42 Series Internal Power Supply from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or ...
Page 18 - Features and Benefits; AC/DC models are rated at 100-250V with a maximum of 4KV surge; Dual-Source power input; 25VDC, 48VDC and 24VDC models are equipped with Dual-Source; For AC models
IPS42 Internal Power Supply Installation and User Guide (11/09) 10 www GarrettCom com . . 2.3 Features and Benefits 100 to 250V range, 4KV surge protected AC/DC models are rated at 100-250V with a maximum of 4KV surge suppression. The only High Voltage AC/DC Ethernet unit on the market that is UL ...
Page 20 - Mounting Dimensions for IPS42 with metal brackets
IPS42 Internal Power Supply Installation and User Guide (11/09) 12 www GarrettCom com . . Installation of the Magnum IPS42 Series of products is a simple procedure. The installation location is dependent upon the physical layout of the Ethernet network and associated cabling. Make sure the unit is i...
Page 21 - circulation and cooling of the rear part of the case.
IPS42 Internal Power Supply Installation and User Guide (11/09) 13 www GarrettCom com . . Note: The metal brackets supplied hold the back of the IPS42 unit out from the panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of the rear part of ...
Page 23 - The Magnum IPS42 Power Supply,; A Magnum IPS42 is shown with the; The metal DIN-Rail mounting hardware is
IPS42 Internal Power Supply Installation and User Guide (11/09) 15 www GarrettCom com . . 3.1.2 DIN-Rail mounting option The Magnum IPS42 Power Supply, designed for use in “Factory Floor” Industrial Ethernet environments, is available for DIN-Rail mounting in an enclosure having DIN Rails. A Magnum ...
Page 24 - Power Cord Installation; For IPS42-DC w/Dual Source and AC/DC models that do not have the power
IPS42 Internal Power Supply Installation and User Guide (11/09) 16 www GarrettCom com . . 3.2 Power Cord Installation For IPS42-DC w/Dual Source and AC/DC models that do not have the power cord installed at the factory, follow the procedures as described below. For detailed technical specifications,...
Page 25 - Slide the power cord cover
IPS42 Internal Power Supply Installation and User Guide (11/09) 17 www GarrettCom com . . Use the Power Cord installation kit (items for Dual Source shown in Fig. 3.2b) to connect the power cord to the unit. Note: For Single Source models, the kit will include a single opening power cord cover and o...
Page 26 - For Dual Source models, positions A and B will be used.; None of the conductor can be exposed after
IPS42 Internal Power Supply Installation and User Guide (11/09) 18 www GarrettCom com . . For Dual Source models, positions A and B will be used. For Single Source models, only position A will be used. NOTE: None of the conductor can be exposed after secured in the terminal block. c. Install the pro...
Page 28 - Hardware operated Alarm Contact; The two screw Alarm Contacts
IPS42 Internal Power Supply Installation and User Guide (11/09) 20 www GarrettCom com . . 3.3 Hardware operated Alarm Contact The two screw Alarm Contacts feature, standard on Magnum IPS42-Series, provides Normally Closed (NC) contacts to which the user can attach one set of status monitoring wires ...
Page 29 - electronics inside of the unit.
IPS42 Internal Power Supply Installation and User Guide (11/09) 21 www GarrettCom com . . 1. Four-position terminal block (positions 1 & 2) as shown in Figure 4.4a 2. The Alarm Relay contact connected to the two terminals (1, 2) is hardware operated. 3. By default it is NC (normally closed). It ...
Page 30 - Before Calling for Assistance
IPS42 Internal Power Supply Installation and User Guide (11/09) 22 www GarrettCom com . . 4.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure ...
Page 31 - product and its associated cables are functioning properly.
IPS42 Internal Power Supply Installation and User Guide (11/09) 23 www GarrettCom com . . 4. Make sure that an AC power cord is properly attached to each Magnum IPS42 Series unit. Be certain that the AC power cord is plugged into a functioning and appropriate electrical outlet. Use the PWR LEDs to v...
Page 32 - When Calling for Assistance; Please be prepared to provide the following information.
IPS42 Internal Power Supply Installation and User Guide (11/09) 24 www GarrettCom com . . 4.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. S...
Page 34 - Shipping and Packaging Information
IPS42 Internal Power Supply Installation and User Guide (11/09) 26 www GarrettCom com . . GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prep...
Page 35 - This material may cause electro-static shock damage to the unit.; outside of the shipping container.
IPS42 Internal Power Supply Installation and User Guide (11/09) 27 www GarrettCom com . . CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) numbe...
Page 36 - provided that the product is returned pre-paid to GarrettCom.
IPS42 Internal Power Supply Installation and User Guide (11/09) 28 www GarrettCom com . . APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this ...