Garland G24-BRL - Manual
Garland G24-BRL – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – TABLE OF CONTENTS; Operating At LOW
- Page 4 – DIMENSIONS AND SPECIFICATIONS – BROILERS; North America & General International Markets
- Page 5 – DIMENSIONS AND SPECIFICATIONS – BROILERS continued; CE Aproved Models
- Page 6 – DIMENSIONS AND SPECIFICATIONS – STANDS
- Page 7 – PRE INSTALLATION; Rating Plate Location
- Page 8 – INSTALLATION continued; Gas Supply; Gas Connections
- Page 9 – Leg Installation
- Page 10 – Assembly Of Broiler; Ventilation
- Page 11 – Grid Rack Seasoning Instructions
- Page 12 – CLEANING AND MAINTENANCE; Cleaning Care of the Grid Racks
- Page 13 – MANUEL; RÔTISSOIRES GARLAND
- Page 15 – TABLE DES MATIÈRES
- Page 16 – DIMENSIONS ET SPÉCIFICATIONS - RÔTISSOIRES; Marchés Nord-Américain Et
- Page 17 – DIMENSIONS ET SPÉCIFICATIONS – RÔTISSOIRES (suite); Modèles homologués CE; Dimension D’entrée Du Gaz; Série GF - Homologué CE - Catégories de gaz; Rapprochez Les Estimations Totales D’entrée Avec
- Page 18 – DIMENSIONS ET SPÉCIFICATIONS - SOCLES
- Page 19 – PRÉINSTALLATION; Emplacement De La Plaque Signalétique
- Page 24 – FONCTIONNEMENT; Instructions D’apprêtage
- Page 25 – ENTRETIEN ET NETTOYAGE; Nettoyage des crémaillères de grille
- Page 27 – LACIÓN Y OPERACIÓN; PARRILAS GARLAND
- Page 28 – INFORMACIÓN IMPORTANTE; nacimiento u otros daños reproductivos.; Mantenga la zona del artefacto libre y alejada de combustibles.
- Page 29 – TABLA DE CONTENIDO
- Page 30 – DIMENSIONES Y ESPECIFICACIONES – PARRILLAS; Mercados de América del Norte e
- Page 31 – DIMENSIONES Y ESPECIFICACIONES – PARRILLAS continuación; Modelos aprobados por la CE
- Page 32 – DIMENSIONES Y ESPECIFICACIONES – SOPORTES
- Page 33 – PREINSTALACIÓN; Ubicación De La Placa De Características
- Page 34 – INSTALACIÓN continuación; Cláusula Específica Para Australia; Conexiones De Gas
- Page 35 – Sellado Sanitario De La Mesada
- Page 36 – Bases Del Gabinete
- Page 37 – Armado De La Parrilla; Ventilación
- Page 38 – OPERACIÓN; Instrucciones De Curado De La Rejilla
- Page 39 – LIMPIEZA Y MANTENIMIENTO; Limpieza De Las Rejillas Asadoras
Part # 4525958 (05/15/09)
Page 1
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com .
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice .
GARLAND COMMERCIAL INDUSTRIES,LLC
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD .
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD .
5E Langley Business Centre
Station Road, Langley SL3 8DS Great Britain
Phone: 01753 485900
Fax: 01753 4859011
Part # 4525958 (05/15/09)
© 2008 Garland Commercial Industries, LLC
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE .
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED .
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER .
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas . This
information shall be obtained by consulting
your local gas supplier .
INSTALLATION AND
OPERATION MANUAL
GARLAND G-BRL & GF-BRL
SERIES BROILERS
Includes Models: G18-BRL, G24-BRL, G30-BRL,
G36-BRL, G48-BRL, GF18-BRL,GF24-BRL,GF30-BRL
and GF36-BRL
Only GF Series Broilers are CE Approved
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13
Españo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Página 27
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Part # 4525958 (05/15/09) Page 3 TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DIMENSIONS AND SPECIFICATIONS – BROILERS . . . . . . . . . . . . . . . . . . . . . . . 4 North America & General International Markets . ...
Part # 4525958 (05/15/09) Page 4 REAR GAS CONNECTION 3/4-14 NPT 7-7/8" [200mm] 2-3/8" [61mm] 34-1/2" [876mm] 24-1/4" [617mm] 5" [127mm] 5-7/8" [149mm] WIDTH 25-1/8" [638mm] 3/16" [5mm] MIN 1/2" [13mm] MAX 22-3/8" [568mm] 7/8" [21mm] 2-1/8" [53mm] 15-7/...
Part # 4525958 (05/15/09) Page 5 DIMENSIONS AND SPECIFICATIONS – BROILERS continued CE Aproved Models Pressure Settings/Injector Size MODEL 2nd Family, Groups H, L & E 3rd Family, Group 3P Setting Pressure Injector Size Setting Pressure Injector Size G20 @ 20 mbar inlet G25 @ 25 mbar inlet G31 @...