COLOR LCD SOUNDER

F

URUNO

F

ree

S

ynthesizer Transceiver

F

ogging

F

ree

D

isplay

COLOR LCD SOUNDER

DISPLAY UNIT FCV-295

7.0 kg 15.4 lb

INTERCONNECTION DIAGRAM

SPECIFICATIONS OF FCV-295

GENERAL

1. Operating Frequencies

The synthesized transceiver works with dual

frequencies in 28 to 200 kHz. Specify

transducer type when ordering, among

28/38/50/68/82/88/107/150/200 kHz

2. Output Power

1/2/3 kW

3. Power Reduction

Auto/10 to 100% (in 10% step)

4. Tx Rate

20 to 3000/min

5. Pulselength

Short1/Short2/Standard/Long/Manual (Manual

Pulselength: 0.1 to 5.0 ms)

6. RX Band

Narrow/Standard/Wide

7. Amplifier

High dynamic range

DISPLAY

1. Display

10.4" color LCD (VGA: 640 x 480)

2. Color

8/16/64

3. Brightness

450 cd/m

2

4. Ranges

5 to 3000 m (Split Range available)

5. Shift

0 to 2000 m

6. Marker Zoom/Bottom-lock Expansion Ranges

5 to 2000 m

7. Display mode

Single (HF/LF), Dual, Single + Zoom,

two Custom Modes

Zoom Mode (Bottom Lock, Bottom Zoom,

Marker Zoom), Mix Mode, Nav data, A-scope

8. Picture Advance Direction

Left, Right, L/R

9. Picture Advance Speed

Stop, 1/16, 1/8, 1/4, 1/2, 1/1, 2/1, 4/1,

Synchronized with own ship speed

10.Alarms

Audio-visual alarms for a preset depth of water,

fish and a preset value of water temperature

11.Language

English, French, Spanish, German, Italian,

Portuguese, Swedish, Danish, Norwegian,

Finish, Greek, Chinese, Japanese, Thai,

Korean, Russian

12.Others

Auto Mode, Interference, Clutter, TVG, Color

Erase, Hue, Temp Graph, A-scope, White Marker

DATA INTERFACE

NMEA0183 (Ver. 1.5, 2.0 or 3.0; Any talker)

Input:

BWC, GGA, GLC, GLL, GNS, GTD, HDG, HDT, MDA,

MTW, MWV, RMA, RMB, RMC, VHW, VTG, XTE

Output: DBT, DPT, MTW, TLL, SDmrk, VHW, RMB, dat

ENVIRONMENTAL CONDITIONS

Display Unit:

-15 ºC to +55 ºC (IEC60945 tested)

Water Resistance: IP55 (When flush mounted)

POWER SUPPLY

12-24 VDC, 45 W max. 100/110/220/230 VAC with optional rectifier

EQUIPMENT LIST

Standard

1. Display Unit

2. Installation Materials and Standard Spare Parts

Option

1. Speed/temperature sensor

ST-02MSB (Thru-hull, bronze), ST-02PSB (Thru-hull, plastic)

2. Temperature sensor

T-02MSB (Thru-hull, bronze), T-02MTB (Transom, bronze),

T-03MSB (Thru-hull, bronze)

3. NMEA cable MJ-A6SPF0003-050C (5 m)

CO-SPEVV-SB-C 2P x 0.2SQLF (5/10/15 m)

4. Rectifier

PR-62

5. Transducer (Specify the frequency and type of transducer)

1 kW: 28F-8 (28 kHz), 50B-6/6B (50 kHz), 50B-9B (50 kHz),

68F-8H (68 kHz), 88B-8 (88kHz), 200B-5S (200 kHz),

50/200-1T (50/200 kHz), 50/200-12M (50/200 kHz)

2 kW: 28F-18 (28 kHz), 28BL-6HR (28 kHz), 38BL-9HR (38 kHz),

50B-12 (50 kHz), 50BL-12/12HR (50 kHz), 82B-35R (66-209

kHz), 88B-10 (88 kHz), 200B-8/8B (200 kHz)

3 kW: 28F-24H (28 kHz), 28BL-12HR (28 kHz), 38BL-15HR (38

kHz), 50F-24H (50 kHz), 50BL-24H/24HR (50 kHz),

68F-30H (68 kHz), 88F-126H (88 kHz), 100B-10R (100

kHz), 150B-12H (150 kHz), 200B-12H (200 kHz)

323 12.7"

310 12.2"

285

11.2"

306 12.0"

185 7.3"

18
0.7”

10
0.4”

62
2.4”

31

1 12.2"

128
5.0"

35°

285

11.2"

288 11.3"

160 6.3"

81 3.2"

310 12.2"

4-Ø6 22

0.9"

106 4.7"

41
1.6"

122 4.8"

274 10.8"

288 11.3"

(238 9.4")

(216 8.5")

18

0.7"

160 6.3"

252 9.9"

63

2.5"

4-Ø36

Fixing hole

Temp. sensor

T-02MSB

T-02MTB

T-03MSB

Speed/temp. sensor

ST-02MSB

ST-02PSB

Position data

(From GPS navigator
or via radar
or Chart Plotter)

NMEA cable

12-24 VDC

100/110/220/230 VAC

Option

Rectifier

PR-62

Transducers

Local supply

Flush mount

6.0 kg 13.2 lb

Cutout for flush mount

FURUNO U.S.A., INC.

Camas, Washington, U.S.A.
Phone: +1 360-834-9300
Fax: +1 360-834-9400

FURUNO ELECTRIC CO., LTD.

Nishinomiya, Hyogo, Japan
Phone: +81 (0)798 65-2111
Fax: +81 (0)798 65-4200, 66-4622

FURUNO (UK) LIMITED

Havant, Hampshire, U.K.
Phone: +44 23 9244 1000
Fax: +44 23 9248 4316

FURUNO FRANCE S.A.S.

Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00
Fax: +33 5 56 13 48 01

FURUNO ESPAÑA S.A.

Madrid, Spain
Phone: +34 91-725-90-88
Fax: +34 91-725-98-97

FURUNO DANMARK AS

Hvidovre, Denmark
Phone: +45 36 77 45 00
Fax: +45 36 77 45 01

FURUNO NORGE A/S

Ålesund, Norway
Phone: +47 70 102950
Fax: +47 70 102951

FURUNO SVERIGE AB

Västra Frölunda, Sweden
Phone: +46 31-7098940
Fax: +46 31-497093

FURUNO FINLAND OY

Espoo, Finland
Phone: +358 9 4355 670
Fax: +358 9 4355 6710

FURUNO POLSKA Sp. Z o.o.

Gdynia, Poland
Phone: +48 58 669 02 20
Fax: +48 58 669 02 21

FURUNO DEUTSCHLAND GmbH

Rellingen, Germany
Phone: +49 4101 838 0
Fax: +49 4101 838 111

LLC “FURUNO EURUS”

St. Petersburg, Russian Federation
Phone: +7 812 767 15 92
Fax: +7 812 766 55 52

TRADEMARK REGISTERED

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

08013U Printed in Japan

Catalogue No. E-405

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Furuno Models

All Furuno Other