Furuno CSH-23 - Manual

Furuno CSH-23

Furuno CSH-23 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
Page: / 98

Table of Contents:

  • Page 3 – SAFETY INSTRUCTIONS
  • Page 4 – ii; TABLE OF CONTENTS; MOUNTING THE EQUIPMENT
  • Page 5 – SYSTEM CONFIGURATION; Figure 1-1 System configuration
  • Page 7 – Optional Equipment
  • Page 8 – Mounting the Hull Unit and Receiver Unit; Location of hull unit; Figure 3-1 Hull unit mounting location
  • Page 9 – Figure 3-2 Maintenance space, example sonar compartment
  • Page 10 – Shortening the retraction tank; XDCR Travel
  • Page 11 – Remarks for installation of retraction tank; space for tightening of bolts and nuts.
  • Page 12 – Installing hull unit on retraction tank; Figure 3-6 Installation of hull unit
  • Page 13 – Figure 3-8 Proper and wrong installation of stay; Fastening receiver unit to hull unit; Figure 3-7 Proper installation of stays; Figure 3-9 Mounting of receiver unit
  • Page 14 – Mounting the display unit/sub-display unit
  • Page 15 – Mounting the Transmitter Unit; Figure 3-11 Transmitter unit; Mounting the Interface Unit
  • Page 16 – Grounding the Equipment; CAUTION; Figure 3-12 Location of ground terminals on equipment
  • Page 17 – Cable Configuration; Figure 4-1 Cable configuration
  • Page 18 – How to Use the Crimping Tool, Pin Extractor; How to use the crimping tool; Push the pin extractor into the pin hole from the side
  • Page 19 – Location of Connectors; Figur
  • Page 20 – Fabricating Cable, Assembling Connectors; Assembling the 38P connector; Figure 4-5 How to assemble the 38P connector; Positioning guide pins
  • Page 21 – Clamping the cable; Figure 4-6 Clamping the cable
  • Page 22 – Assembling 38P connector; Figure 4-10 Assembling 38P connector
  • Page 23 – Clamp the cable as shown in below.; Fabricating cable DPYCY-
  • Page 24 – Figure 4-15 Assembling 38P connector
  • Page 25 – Secure the cable with the cable clamp.; Fabricating cable 10S1259 (connected to terminal board TB-B1)
  • Page 26 – Figure 4-19 Assembling 38P connector; Figure 4-20 Clamping the cable
  • Page 28 – Connection of Transducer Cables; Lead the cable into the receiver unit and clamp it as follows.
  • Page 29 – Connection of Interface Unit CS-120A; Connections for true motion and target lock
  • Page 31 – Connections for ES picture and FNZ markers
  • Page 32 – Wiring
  • Page 33 – Fabrication, assembling 10P and 7P connectors; Figure 4-30 Fabrication of 10P, 7P connectors
  • Page 34 – Connections; Refer to the interconnection diagram at the end of this manual.; DIP switch setting; Figure 4-31 DIP switch setting on RDCB board in the sub-display unit
  • Page 35 – Figure 4-33 Connections for synchronizing transmission with
  • Page 36 – To output KP to other sonar or echo sounder, wire units as follows.; Menu setting
  • Page 37 – Interlocking Operation with Other Sonar; Connections for interlocking functions; Two sonars; Figure 4-35 connections for interlocking function of two sonars; Three sonars
  • Page 38 – Connections for interlocking remote control; Figure 4-37 Connections for interlocking remote control
  • Page 39 – CHANGING POWER SPECIFICATIONS; Figure 5-1 Tap connections on the transformer in the power unit
  • Page 40 – ADJUSTMENT AND CHECK; Terminal; Figure 6-1 Display unit front panel
  • Page 41 – Heading Adjustment; Figure 6-3 Heading adjustment
  • Page 42 – DIP Switch Setting in the Display Unit
  • Page 43 – Setting and Adjustment of the Interface Unit
  • Page 44 – Setting for DIP switch
  • Page 45 – Priority for data; Basic priority; GPS fixing position priority
  • Page 47 – Installing the Unit; fishing ground or the area surrounding the vessel.; Mounting procedure; base with two bolts.
  • Page 48 – cables; Protective earth; Connectors for Monitor; BNC connector: Use five 75
  • Page 50 – PACKING LIST
  • Page 52 – 工事材料表
Loading the manual

COLOR SCANNING SONAR

MODEL

CSH-23/23F/24/24F

Back

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - SAFETY INSTRUCTIONS

i WARNING Turn off the power at the switchboardbefore beginning the installation. Fire or electrical shock can result if thepower is left on. Do not install the equipment where itmay get wet from rain or water splash. Water in the equipment can result in fire,electrical shock or equipment damage. Be...

Page 4 - ii; TABLE OF CONTENTS; MOUNTING THE EQUIPMENT

ii TABLE OF CONTENTS 1. SYSTEM CONFIGURATION ............................................................................ 1 2. EQUIPMENT LISTS .......................................................................................... 2 3. MOUNTING THE EQUIPMENT 3.1 Mounting the Hull Unit and Receive...

Page 5 - SYSTEM CONFIGURATION; Figure 1-1 System configuration

1 1. SYSTEM CONFIGURATION STANDARD OPTION REMOTE CONTROL BOX CSH-116 DISPLAY UNIT CSH-230 (CSH-23) MONITOR (MU-151C)*orCOMMERCIAL MONITOR* SUB DISPLAY* CSH-236 STEP-DOWN TRANSFORMER PT-400 VI-1100A INTERFACE UNIT FNZ JOINT BOX CS-170 100 VAC 110/115/220/230 VAC SPEED LOG NAVIGATOR CURRENT INDICATOR ...

Other Furuno Models

All Furuno Other