Page 3 - SAFETY INSTRUCTIONS; WARNING; CAUTION; Standard Steering; CAUTION
i SAFETY INSTRUCTIONS WARNING CAUTION Have a qualified serviceman do theinstallation. Only qualified personnel should work inside the equipment. Use Chugoku Toso brand Marine Star 20 anti-fouling paint or the equivalentfor the transducer. Coat thinly and evenly. A thick coat can reduce output power....
Page 4 - ii; SYSTEM CONFIGURATIONS
ii SYSTEM CONFIGURATIONS DISTRIBUTOR UNIT DS-610 JUNCTION BOX DS-640 TRANSCEIVER UNIT DS-620 IEC 61162 Output x 5 IEC 61162 Input x 3 Distance Run Pulse x 4 Alarm System External KP x 1 KP Output x 1 RATE-OF- TURN GYRO DS-340 DS-600/ DISPLAY UNIT MAIN DISPLAY UNIT DS-600/ RD-50/RD-20 DISPLAY UNIT SU...
Page 5 - iii; EQUIPMENT LISTS; Standard supply; Name
iii EQUIPMENT LISTS Standard supply Name Type Code No. Qty Remarks Display Unit DS-600 - 1 8.4” color LCD Distributor Unit DS-610 - 1 Transceiver Unit DS-620 - 1 Transducer DS-630 - 1 No watertight connector Select one. DS-631 - w/watertight connector Transducer Tank DS-660 - 1 For DS-630/631 Select...
Page 6 - iv; Optional Supply
iv Optional Supply Name Type Code No. Qty Remarks Rate-of-turn Gyro DS-340-60 000-027-992 1 100VAC DS-340-61 000-028-017 110VAC DS-340-62L 000-028-018 115/120VAC DS-340-70 000-028-019 200VAC DS-340-72 000-028-020 220VAC DS-340-74 000-028-021 230/240VAC Display Unit DS-600 - 1 8.4” color LCD Hanger O...
Page 7 - Mounting consideration; Flush mount; NOTICE
1-1 1. INSTALLATION 1.1 Display Unit DS-600 Mounting consideration The display unit can be installed on a desktop, on the underside of a table, or flush mounted in a panel. When you select a mounting location, keep in mind the following points: • Locate the display unit away from exhaust pipes and v...
Page 8 - Desktop or table underside mount
1. INSTALLATION 1-2 Note: Dimensions for the cutout are different depending on the mounting location, indoor or out- door. For the outdoor mouting, ask dockyard to construct a waterproof case for the display unit. 2. Make four pilot holes for self-tapping screws (diameter: 5 mm) in the location indi...
Page 9 - How to set the cosmetic cap and alarm lid assy.
1. INSTALLATION 1-3 8. Set a cosmetic cap to each fixing hole on the front panel. How to set the cosmetic cap and alarm lid assy. Set a cosmetic cap to each fixing hole on the front panel as shown in the illustration below. For the display unit to be used as a sub display, attach the alarm lid (supp...
Page 10 - Transceiver Unit DS-620; Installation considerations
1. INSTALLATION 1-4 1.2 Transceiver Unit DS-620 Installation considerations • Since the transceiver unit generates heat, install it in a dry, well-ventilated place. The cooling fans at the top of the unit must not be obstructed, to allow heat to escape. • This unit is designed for bulkhead mounting ...
Page 11 - Distributor Unit DS-610
1. INSTALLATION 1-5 1.3 Distributor Unit DS-610 The distributor unit can be mounted on the deck or on a bulkhead. Consider the following points when selecting a mounting location. • Select a location which is both well ventilated and low in humidity to keep the unit cool.• For bulkhead mounting, be ...
Page 12 - Transducer; Installation location
1. INSTALLATION 1-6 1.4 Transducer The performance of this equipment is directly dependent on the installation of the transducer. The installation of the transducer and the tank must be accomplished by a dockyard referring to the installation drawings at the later part of this manual. 1.4.1 Installa...
Page 13 - Installation using the transducer tank DS-660; Hull
1. INSTALLATION 1-7 1.4.2 Installation using the transducer tank DS-660 Transducer tank DS-660, sectional view 1. Remove flange (4), fixing plate (5), fixing gland (6), washer (7) and gasket (8) from the tank.2. Set the tank to the place which was selected at paragraph 1.4.1. The “FORE-AFT” line on ...
Page 14 - Transducer cable
1. INSTALLATION 1-8 9. Use M16 nut (11), spring washer (12) and flat washer (13) to fix the transducer (1) w/fixing plate to the fixing flange (4). 10.For the transducer DS-631, do the following steps: 1) Attach the grommet (supplied) to the location marked with a white line on the transducer cable....
Page 15 - Metal fixing
1. INSTALLATION 1-9 5) Attach the metal fixing (supplied) to the connector, and use two bolts M6x20 and spring washers M6 to fix them. 11.Pass the fixing gland (6), washer (7) and gasket (8) through the transducer cable (DS-631: cable assy), and slide them to the white line on the cable. 12.Pass the...
Page 17 - Installation with gate valve DS-661
1. INSTALLATION 1-11 1.4.3 Installation with gate valve DS-661 DS-661 gate valve, sectional view Note: To install the gate valve, service space of 1000 mm height is necessary. For details, see the installation drawing at the back of this manual. 1. When your unit is shipped assembled, remove the fiv...
Page 21 - How to open the gate valve; Fore mark
1. INSTALLATION 1-15 18.Check that fore marks are aligned, and fasten hex. nut (17), spring washer (18) and hex. bolt (19) tightly. 19.Fasten hex. nut (20), spring washer (21) and flat washers (22) removed at step 4 to stud bolt on the seachest cap. The distance between the seachest cap (4) and flan...
Page 23 - Qty
1. INSTALLATION 1-17 1.6 Installation of Display Unit with DS-605 (Water Proof Box, option) For installation of the display unit on the wings of the bridge, use the optional water proof box DS-605. Fix the DS-605 on the bulkhead and set the display unit therein. Mounting considerations The DS-605 ha...
Page 25 - Clamping gasket
1. INSTALLATION 1-19 3) Pass the cable through the cable gland as shown below. 4) Put the flush mounting sponge to the flange from the rear side of the DS-600.5) Open the front cover of the DS-605 and connect the ground wire attached inside the DS- 605 to the ground terminal on the rear of the DS-60...
Page 26 - How to change orientation of the front cover of DS-605
1. INSTALLATION 1-20 How to change orientation of the front cover of DS-605 The front cover of the DS-605 can be oriented up, down, right or left. To change the orientation of the front cover, do the following. Note: Set the front cover so the FURUNO logo on the cover is right side up. The drain hol...
Page 27 - Leveling adjustment; Sensor
1. INSTALLATION 1-21 1.8 Rate-of-Turn Gyro DS-340 (option) The rate-of-turn gyro must be installed, in a location with minimal vibration, so that the sensor in-side the unit is level to within 1 degree. (There is no designation for orientation of the unit.) Select the location considering that the c...
Page 29 - WIRING; Precautions for cable installation
2-1 2. WIRING Refer to the interconnection diagram at the back of this manual to connect cables. Precautions for cable installation Observe the following guidelines to prevent noise, interference problem. • The transducer cable carries very weak signals (amplitude less than 0.1 μ V), which are easil...
Page 30 - Connection of WAGO connector; How to connect wires to WAGO connector
2. WIRING 2-2 Connection of WAGO connector Remove the WAGO connector from each unit and connect each cable core to the WAGO connector. See the interconnection diagram at the back of this manual. The terminal opener is attached inside each unit. 2.1 Distributor Unit DS-610 The Distributor Unit DS-610...
Page 33 - DS-620 Transceiver unit
2. WIRING 2-5 2.2 Transceiver Unit DS-620 Cables TTYCY-4S, DPYCY-4 and the transducer cable are connected to the DS-620. Fabricate and pass them through their respective the cable clamps at the bottom. Note: The transducer cable has nine twisted-pairs of signal lines. Be careful to con- nect them to...
Page 37 - How to Use the Service Menu; Input cursor
3-1 3. MENU SETTINGS After the installation is completed, set up the system from the Service and System menus. 3.1 How to Use the Service Menu 1. Press the [PWR] key while pressing the [DISP] key to show the Service menu. Service menu 2. Press S or T to select a menu item, and press the [ENT] key to...
Page 39 - How to Set the System Menu; How to show the System menu; How to set ship’s data
3. MENU SETTINGS 3-3 3.2 How to Set the System Menu Set the items on the System menu after completing those on the System menu. 3.2.1 How to show the System menu 1. Press the [PWR] key to turn the power on.2. Press the [MENU/ESC] key to show the main menu.3. Press T to select [System], and press the...
Page 40 - How to enter offset values; Item
3. MENU SETTINGS 3-4 2. Select an item, and press the [ENT] key to show the setting window. Refer to the table in below to enter the dimensions. 3. Press the [MENU/ESC] key to close the menu. 3.2.3 How to enter offset values 1. Press S to select [Offset Data], and [ENT] key to show the Offset Data m...
Page 41 - How to correct the ship’s speed
3. MENU SETTINGS 3-5 7. Enter the offset value if transducer is not installed perfectly with ship’s fore-aft line (setting range: -60.0 to +60.0 ° ). Measure the difference between ship’s fore-aft line and the line on the transducer, and enter it. 3.2.4 How to correct the ship’s speed Correct the sp...
Page 43 - APPENDIX 1 CALIBRATION; Milepost run
AP-1 APPENDIX 1 CALIBRATION Milepost run It is common practice to check a new ship’s performance at an official trial run. Take this op-portunity to calibrate the DS-60. In practice, the ship speed is evaluated as follows. 1. Calculation with transit posts Steer the ship at a steady speed on the tes...
Page 44 - Reset the distance run figure of DS-60 to zero by selecting
APPENDIX AP-2 2. Calculation with DS-60 To measure the distance run between points A and B by DS-60, do the following: 1. Reset the distance run figure of DS-60 to zero by selecting Reset on the Trip DIST menu at the moment the ship passes point A. 2. Run the ship from A to B at full speed, timing w...
Page 46 - APPENDIX 2 JIS CABLE GUIDE; Insulation Type
AP-4 APPENDIX 2 JIS CABLE GUIDE D T M TT P Y C Y S -S 3. Sheath Type 4. Armor Type 5. Shielding Type 6. Core Sheath Ethylene Propylene 2. Insulation Type 1. Core Type Double core power line Triple core power line 1mm Multi core 0.75mm twisted pair communications (1Q = quad cable) Corrosive resistant...