Page 2 - FRIEDRICH AIR CONDITIONING CO. 1-1
1. Precautions FRIEDRICH AIR CONDITIONING CO. 1-1 1. Precautions 1. Warning: Prior to repair, disconnect the power cord from the circuit breaker. 2. Use proper parts: Use only exact replacement parts. (Also, we recommendreplacing parts rather than repairing them.) 3. Use the proper tools: Use the pr...
Page 3 - Item; FRIEDRICH AIR CONDITIONING CO.
2.Product Specifications 2-1 Table Item Unit of Measure SP06A10 SP08A10 SP10A10 SP12A10 Type WINDOW Dimension: (Width × Height × Depth) mm 520 × 345 × 485 600 × 394 × 595 Voltage Volt 115 Phase - SINGLE Frequency Hz 60 Operation Current A 5.4 6.6 9.3 10.5 Power Consumption W 610 740 1000 1170 Refrig...
Page 4 - MEMO; -3 FRIEDRICH AIR CONDITIONING CO.
MEMO 2-3 FRIEDRICH AIR CONDITIONING CO. DB98_04511A(2)-1 2/18/03 4:09 PM Page 2-4
Page 5 - -4 FRIEDRICH AIR CONDITIONING CO.
2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control W H H Front view Side view (Unit : mm) 2-4 FRIEDRICH AIR CONDITIONING CO. DB98_04551A(3)_1 2...
Page 6 - FRIEDRICH AIR CONDITIONING CO. 3-1; Installation and Operating Instructions
FRIEDRICH AIR CONDITIONING CO. 3-1 3. Installation and Operating Instructions 3-1 Installation 3-1-1 Selecting Area for Installation 1. Make sure that you install the unit in an area providing good ventilation. The air conditionermust not be blocked by any obstacle affecting theair flow near the air...
Page 7 - -2 Function Description; ) Default value after power reset; -2 FRIEDRICH AIR CONDITIONING CO.
3-2 Function Description 3-2-1 Cooling operation mode The compressor is turned on and off according to the ambient temperature and set temperature.1) Compressor on and off control • Compressor on and off control according to the ambient temperature * The compressor is turned off when "ambient te...
Page 8 - FRIEDRICH AIR CONDITIONING CO. 3-3; And, automatically SET OFF after operated while 8 Hour; -2-6 LED display indication in case of error detection; ) Set operation in case of error occurrence.
FRIEDRICH AIR CONDITIONING CO. 3-3 3-2-4 Sleep operation mode 1) Enable to sleep operation only when cooling operation.2) First, 7-SEG LED DISPLAY "SLEEP" while 15 second, Second, 7-SEG LED DISPLAY "8Hr" And, automatically SET OFF after operated while 8 Hour 3) If sleep operation, se...
Page 9 - -4 FRIEDRICH AIR CONDITIONING CO.
MEMO 3-4 FRIEDRICH AIR CONDITIONING CO. DB98_04511A(2)-1 2/18/03 4:09 PM Page 2
Page 10 - FRIEDRICH AIR CONDITIONING CO. 4-1; Disassembly and Reassembly; -1 Compressor Replacement Flow Chart
FRIEDRICH AIR CONDITIONING CO. 4-1 4. Disassembly and Reassembly 4-1 Compressor Replacement Flow Chart Locate cause of defect Release refrigerant Disconnect electrical wiring from compressor Cut refrigerant lines from compressor Plug disconnected lines Replace compressor Inspect electrical wiring fo...
Page 11 - -2 FRIEDRICH AIR CONDITIONING CO.; -2-2 Replacing and refilling the refrigerant oil
4-2 FRIEDRICH AIR CONDITIONING CO. 4-2 Checking the oil 4-2-1 Oil quality 4-2-2 Replacing and refilling the refrigerant oil 1. Change the compressor - DO NOT recharge the oil as the compressor itself is already charged. 2. Change the condenser .... add 50cc3. Change the evaporator .... add 50cc4. Wh...
Page 13 - Case evap up
Disassembly and Reassembly Procedure( SP10A10/SP12A10 ) No. Part Name Procedures Remarks 4 Plate reinf& Case evap up 1..Remove 4 screws on the partition and case cond. 2.Remove the plate reinf. (The shape maybe different depend on models) 3.Remove the seal sticked on the case evap up carefully. ...
Page 15 - Frame
Disassembly and Reassembly Procedure( SP06A10/SP08A10 ) No. Part Name Procedures Remarks 4 Frame up 1..Remove 2 screws on the frame up and case cond. 2.Remove all the screws on the frame up. 3.Pull the frame up upward. 5 Blower 1.Remove 3 screws on the evaporator. 2.Pull the evaporator from frame lo...
Page 16 - FRIEDRICH AIR CONDITIONING CO. 5-1; -1 Basic Checkpoints for Troubleshooting; ) Is the voltage of the power source appropriate ?
FRIEDRICH AIR CONDITIONING CO. 5-1 5. Troubleshooting 5-1 Basic Checkpoints for Troubleshooting Check the basic checkpoints first to determine whether it is machine trouble or a problemin the operation method. When it is not related to the basic checkpoints, perform checkingin accordance with the pr...
Page 17 - -2 FRIEDRICH AIR CONDITIONING CO.; -2 Troubleshooting by Symptom
5-2 FRIEDRICH AIR CONDITIONING CO. 5-2 Troubleshooting by Symptom 5-2-1 No power 1) Check points (1) Is the voltage of the power source normal ? (the rating voltage ±10% range.) (2) Is the electric wire in good contact ?(CN 71, RY 71)(3) Is the output voltage of the IC01(KA 7812) normal ?(DC 11.5V ~...
Page 18 - FRIEDRICH AIR CONDITIONING CO. 5-3; -2-2 When the Touch Key pad and Led Display
FRIEDRICH AIR CONDITIONING CO. 5-3 Troubleshooting 5-2-2 When the Touch Key pad and Led Display 1) Check points (1) Is the voltage of the power source normal ? (the rating voltage ±10% range.)(2) Is the electric wire in good contact ?(CN71, RY71)(3) Is the connection of the assembly main PCB, and TO...
Page 19 - -4 FRIEDRICH AIR CONDITIONING CO.
5-4 FRIEDRICH AIR CONDITIONING CO. Troubleshooting 5-2-3 When the remocon is not operated 1) Check points (1) Is the voltage of the power source normal ? (the rating voltage ±10% range. )(2) Is the electric wire in good contact ? (CN71, RY71)(3) Is the assembly main PCB in good contact with the TOUC...
Page 20 - FRIEDRICH AIR CONDITIONING CO. 5-5; -2-4 When the compressor is not operated
FRIEDRICH AIR CONDITIONING CO. 5-5 Troubleshooting 5-2-4 When the compressor is not operated 1) Check points (1) Is the voltage of the power source normal ? (the rating voltage ±10% range. )(2) Is the desired temperature lower than the indoor temperature in the “COOL” mode? (Compressor stopped) (3) ...
Page 21 - FRIEDRICH AIR CONDITIONING CO. 5-7; -2-5 When the fan motor does not operated
FRIEDRICH AIR CONDITIONING CO. 5-7 Troubleshooting 5-2-5 When the fan motor does not operated 1) Check points (1) Is the voltage of the power source normal ? (the rating voltage ±10% range. )(2) Is the electric wire in good contact ?(CN71, RY71)(3) Is the starting condenser(FAN MOTOR) in good contac...
Page 22 - FRIEDRICH AIR CONDITIONING CO. 6-1; Exploded View and Parts List; EXPLODED
FRIEDRICH AIR CONDITIONING CO. 6-1 6. Exploded View and Parts List 6-1 Main unit You can search for the updated part codenumber through the ITSELF. URL : http://itself.sec.samsung.co.kr DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 3 4 33 21 23 24 5 6 7 8 9 10 1 1 13 15 16 17 19 14 20 18 28 25 29 26 27 ...
Page 24 - FRIEDRICH AIR CONDITIONING CO. 6-3; Exploded view and part list
FRIEDRICH AIR CONDITIONING CO. 6-3 6. Exploded view and part list 6-3 Main unit DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 3 4 30 11 13 19 21 20 18 23 22 25 37 EXPLODED VIEW S...
Page 26 - FRIEDRICH AIR CONDITIONING CO. 7-1; -1 Refrigerating Cycle Block Diagram; Membrane Pad control
FRIEDRICH AIR CONDITIONING CO. 7-1 7. Block Diagram 7-1 Refrigerating Cycle Block Diagram PINCH PIPE (SERVICE VALVE) SUCTION LINE ACCUMULATOR/COMPRESSOR EVAPORATOR CAPILLARY TUBE CONDENSER DISCHARGE LINE PINCH PIPE (SERVICE VALVE) 7-2 Basic Structure 7-2-1 Micom Control Diagram A/D converter • Compr...
Page 27 - -2 FRIEDRICH AIR CONDITIONING CO.
7-2 FRIEDRICH AIR CONDITIONING CO. Block Diagram 7-2-2 Micom pin assignment KS88C4716 GRID5 SEG-DATA(d) SEG-DATA(e) SEG-DATA(f) SEG-DATA(g) SEG-DATA(h) SEG-DATA(a) EEPROM CLK EEPROM IN EEPROM OUT BUZZER OPTION JIG OUTPUT OPTION SENSOR THERMIS- TOR(103AT) OPTION OPTION OPTION OPTION SAVE OPTION SWING...
Page 28 - FRIEDRICH AIR CONDITIONING CO. 7-3
MEMO FRIEDRICH AIR CONDITIONING CO. 7-3 DB98_04511A(2)-2 2/18/03 4:12 PM Page 9-1
Page 29 - -1 FRIEDRICH AIR CONDITIONING CO.; ’Y Main PCB
8-1 FRIEDRICH AIR CONDITIONING CO. 8. PCB Diagram 8-1 ASS ’Y Main PCB DB98_04511A(2)-2 2/18/03 4:12 PM Page 9-2 8. PCB Diagram 8-1 ASS ’Y Main PCB DB98_04511A(2)-2 2/18/03 4:12 PM Page 9-2 8. PCB Diagram 8-1 ASS ’Y Main PCB DB98_04511A(2)-2 2/18/03 4:12 PM Page 9-2 8. PCB Diagram 8-1 ASS ’Y Main PCB...
Page 30 - FRIEDRICH AIR CONDITIONING CO. 8-2; Part List
FRIEDRICH AIR CONDITIONING CO. 8-2 PCB Diagram ■ Part List DB98_04511A(2)-2 2/18/03 4:33 PM Page 10-1 NO. DESCRIPTION SPECIFICATION Q'TY REMARK DB93-01492A 1 CHIP IC ULN2003AD 1 IC03 2 BRIDGE DIODE DF06S 1 BD61 3 REGULATOR KA7805 1 IC02 4 REGULATOR KA7812 1 IC01 5 C-AL 100µF/10V 1 C105 6 C-AL 1000µF...
Page 31 - -3 FRIEDRICH AIR CONDITIONING CO.; PCB PARTS
8-3 FRIEDRICH AIR CONDITIONING CO. DB98_04511A(2)-2 2/18/03 4:12 PM Page 10-2 19 R-CHIP 6.8k,0805,5% 1 1 R801 20 SWITCH-TACT TSTB-2,160GF 5 5 SW01-SW05 21 CONNECTOR SMAW250-02,RED 1 1 CN41 22 HARNESS DB39-00806A 1 1 CN92 23 JUMP WIRE PH0.6,L7.5mm 10 10 J1,J2,J4,J6,J9,J10,J13-J16 24 JUMP WIRE PH0.6,L...
Page 32 - FRIEDRICH AIR CONDITIONING CO. 9-1
FRIEDRICH AIR CONDITIONING CO. 9-1 9. Wiring Diagram DB98_04511A(2)-2 2/18/03 4:12 PM Page 10-3
Page 33 - 0-1 FRIEDRICH AIR CONDITIONING CO.; Schematic Diagrams; P C B P O W E R; P C B M A I N
10-1 FRIEDRICH AIR CONDITIONING CO. 10-1 PCB 10. Schematic Diagrams DB98_04511A(2)-2 2/18/03 4:12 PM Page 10-4 P C B P O W E R A C I N P U T C O M P R E S S O RC A P A C I T O R S R C . M O . L . P C C O M P E R S S O R FAN MOTORCAPACITOR F A N M O T O R F.M S M H I G H M I D L O W H I G H M I D L O...