Fluke 943-27 - Manual

Fluke 943-27

Fluke 943-27 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
Page: / 45

Table of Contents:

  • Page 3 – Table of Contents
  • Page 5 – Section 1; General Information; Description
  • Page 6 – Detector
  • Page 10 – Equipment; Recommended Spare Parts; Inspection
  • Page 13 – Section 2; Theory of Operation; Functional Description
  • Page 17 – Preamplifier Switch & Jumper Settings
  • Page 19 – Section 3; Operation; Preamplifier Mounting; Electrical Interface
  • Page 22 – Normal Operation; Alarms; Fail Alarm; Power Failure
  • Page 23 – Firmware Version; Configuration Functions
  • Page 24 – Set Point Error Codes
  • Page 26 – Section 4; Maintenance, Calibration and Troubleshooting; Electronic Calibration; Electronic Adjustments
  • Page 27 – Troubleshooting / Adjustments
  • Page 28 – Appendix A; Connector Designations
  • Page 30 – Appendix B; Applicable Drawings
  • Page 32 – Appendix C; Bill of Materials
  • Page 34 – Appendix D; Cable Termination Instructions; D.1 Cable Termination Instructions; Detector Cable Termination:; Detector Field Cable Preparation, “MS” Connector:
  • Page 42 – Appendix E; Modification Sheets, Engineering Instructions; E.1 Modification Sheets, Engineering Instructions
Loading the manual



Victoreen

®

Digital Preamplifier, Model 943-227-15,for use with

Model 943-27 Current Mode Beta Detector







Operator Manual


















February 2008
Manual No. 943-227-15-1, Rev. 3

©

2007, 2008 Fluke Corporation, All rights reserved. Printed in U.S.A.

All product names are trademarks of their respective companies

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Table of Contents

Table of Contents Section 1: General Information ............................................................................................................. 1-1 1.1 General Description ............................................................................................................... 1...

Page 5 - Section 1; General Information; Description

General Information General Description 1 1- 1 Section 1 General Information 1.1 General Description The Victoreen ® Model 943-227-15 Digital Preamplifier, is designed to operate with the Model 943-27, Current Mode Beta Scintillation detector and the Model 942A-200C Series Digital Ratemeter (UDR) or...

Page 6 - Detector

943-227-15 Digital Preamplifier Operator Manual 1- 2 Table 1-1. 943-227-15 Variations and Compatible Equipment Preamplifier Variations Application Detector Readout 943-227-15 Digital Preamplifier Transmission Distances Less than 50 feet 943-27-31 Beta Detector, Current Mode Operation 942A-200C Digit...

Other Fluke Models

All Fluke Other