Fluke 65 - Manual

Fluke 65

Fluke 65 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Safety Information; Warning; To avoid possible personal injury:
  • Page 3 – Specifications
  • Page 4 – Maintenance; Match the; The
  • Page 5 – Required Equipment; Setting Up for Performance Tests and Calibration; Caution
  • Page 6 – Calibration Adjustments
  • Page 8 – Replacement Parts
Loading the manual

®

PN 1554518

January 2000

©2000 Fluke Corporation. All rights reserved. Printed in U.S.A.

1

Model 65

Infrared Thermometer

Calibration Information

Introduction

This calibration information for the Fluke 65 Infrared Thermometer (also referred to as “the UUT”) provides
the following information:

Safety information

Specifications

Basic maintenance

Equipment required for performance tests and calibration

Performance test procedures

Calibration adjustment procedures

List of replaceable parts

For complete operating instructions, refer to the Model 65 Infrared Thermometer Instruction Sheet.

Contacting Fluke

To locate an authorized service center, visit us on the World Wide Web at www.fluke.com. Or, call Fluke as
follows:

USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-678-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Safety Information; Warning; To avoid possible personal injury:

Model 65 Calibration Information 2 Safety Information A Warning To avoid possible personal injury: • The information provided in this manual is for the use of qualified personnel only. Do not perform the verification tests or calibration proceduresdescribed in this manual unless you are qualified to...

Page 3 - Specifications

Specifications 3 Specifications Measurement Range − 40 °C to + 500 °C ( − 40 °F to + 932 °F) Operating Temperature (Ambient) 0 °C to + 50 °C ( + 32 °F to + 122 °F) Storage Temperature − 20 °C to + 70 °C ( − 4 °F to + 158 °F), without battery Display Resolution Below 200 °: 0.1° Above 200 °: 1° Measu...

Page 4 - Maintenance; Match the; The

Model 65 Calibration Information 4 Maintenance Installing the Batteries Remove the holster to access the battery door. Figure 1 shows how to replace the batteries. Caution • Match the + and − polarities of the battery with the battery case. • Do not attempt to recharge the batteries. • Do not throw ...

Other Fluke Models