Loading the manual

®

80T-IR/E

Extended Range Infrared

Temperature Probe

Instruction Sheet

Introduction

The Fluke 80T-IR/E Extended Range Infrared
Temperature Probe (the probe) is a noncontact
temperature measurement accessory for use with a test
instrument capable of measuring DC volts in the
millivolt range such as a digital multimeter (DMM). The
probe has a temperature range of 32°F to 1000°F, with
a basic accuracy of 3% of reading, and an output of 1
mV dc per °F.

Temperature is measured by pointing the probe at the
surface to be measured, and reading the temperature
on the test instrument display.

Box Contents
Temperature Probe, Battery (installed), Instruction
Sheet, and Warranty Card.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WARNING; CAUTION

Safety InformationThe 80T-IR/E complies with IEC Publication 1010-1-1990 including Amendment 1, CSA C22.2 No. 231,ANSI/ISA-S82.01 and .03 Safety Standards. W WARNING IF TARGET EMMISSIVITY IS LESS THAN 0.95, THEPROBE CAN INDICATE A TEMPERATURE LOWERTHAN THE ACTUAL TARGET TEMPERATURE.AVOID TOUCHING TH...

Page 4 - Avoid touching; switch

300mV V V OFF 0 10 20 30 300mV V V OFF A A ! 1000V 750V FUSED 10A RANGE PRESS AUTORANGE 300mA COM V 1 SEC TOUCH HOLD Avoid touching or holding cone ON/OFF switch Battery clip Battery 9V DC Battery door Coiled cable Banana plugs 3 2 1 4 ° C ° F ° C/ ° F switch Figure 1. Display CodesUnder the conditi...

Page 5 - Battery power is low.

Table 1. Display Codes Condition Action 1041 ° F Target temperatureis over range. Select target withinprobe's specifiedtemperature range. -135 ° F The temperature ofthe probe is nearthe low ambientoperating rangelimit.** Ensure that theprobe is within thespecified ambientoperating range. -192 ° F Ba...

Other Fluke Models

All Fluke Other