Fluke 5725A - Manual

Fluke 5725A

Fluke 5725A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
149 Page 149
150 Page 150
151 Page 151
152 Page 152
153 Page 153
154 Page 154
155 Page 155
156 Page 156
157 Page 157
158 Page 158
159 Page 159
160 Page 160
161 Page 161
162 Page 162
163 Page 163
164 Page 164
165 Page 165
166 Page 166
167 Page 167
168 Page 168
169 Page 169
170 Page 170
171 Page 171
172 Page 172
173 Page 173
174 Page 174
175 Page 175
176 Page 176
177 Page 177
178 Page 178
179 Page 179
180 Page 180
181 Page 181
182 Page 182
183 Page 183
184 Page 184
185 Page 185
186 Page 186
187 Page 187
188 Page 188
189 Page 189
190 Page 190
191 Page 191
192 Page 192
193 Page 193
194 Page 194
195 Page 195
196 Page 196
197 Page 197
198 Page 198
199 Page 199
200 Page 200
201 Page 201
202 Page 202
203 Page 203
204 Page 204
205 Page 205
206 Page 206
207 Page 207
208 Page 208
Page: / 208

Table of Contents:

  • Page 3 – Table of Contents; Chapter
  • Page 5 – Contents
  • Page 7 – List of Tables; Table; AC Voltage Secondary Performance Specifications and Operating
  • Page 9 – List of Figures; Figure Title Page
  • Page 13 – WARNING; LETHAL VOLTAGE; Terms in this Manual
  • Page 15 – FOR QUALIFIED SERVICE; Also refer to the preceding Operator Safety Summary; Do Not Service Alone; High voltage may still be present even after disconnecting power.
  • Page 17 – Chapter 1; Introduction and Specifications; Title
  • Page 19 – Introduction; Capacitive load limits are increased to 1000 pF.
  • Page 21 – How to Use the Manuals; 725A Getting Started Manual; Cable connections to a UUT for amplified voltage and current
  • Page 22 – 700A/5720A Series II Remote Programming Reference Guide
  • Page 23 – DC Voltage Specifications
  • Page 27 – AC Voltage Specifications
  • Page 33 – Resistance Specifications
  • Page 37 – DC Current Specifications
  • Page 39 – AC Current Specifications
  • Page 45 – General Specifications
  • Page 47 – Chapter 2; Installation
  • Page 49 – Warning
  • Page 51 – Service Information; Information; Considerations; Caution
  • Page 52 – Connect the other end to the 5700A connector labeled 5725A.
  • Page 53 – Selecting Line Voltage; 0% and a frequency range of 47 to 63 Hz. The line; CAUTION
  • Page 54 – Note
  • Page 55 – Connecting to Line Power
  • Page 57 – Chapter 3; Operating Notes
  • Page 61 – Rear Panel Features
  • Page 63 – Turning on the 5725A Amplifier
  • Page 64 – Up
  • Page 65 – 725A Operating Functions and Modes; -6. 5725A Operating Functions and Modes; Voltage Standby
  • Page 66 – Standby; The BOOST indicator on the 5700A is lit.
  • Page 69 – Conditions That Activate the 5725A
  • Page 71 – Chapter 4; Theory of Operation
  • Page 73 – 00V) appears on the internal heat sink; Extended frequency range for high ac voltage
  • Page 75 – Overall Functional Description; 1A AC Function; 100V AC Range Functional Description; Active assemblies in the 5725A ac voltage function are as follows:
  • Page 76 – 1A Range Functional Description
  • Page 77 – Operation in the 11A DC Range; Voltage and Current Standby Modes
  • Page 78 – The following list describes the five 5725A out-guard lines:
  • Page 79 – The following list describes the 11 5725A in-guard lines:
  • Page 81 – Detailed Circuit Description
  • Page 85 – 5V supplies. If either of these supplies
  • Page 89 – 1A dc or 11A ac. The 5700A drives the Current Amplifier
  • Page 92 – C signal the
  • Page 93 – Current Standby
  • Page 94 – The High Voltage Amplifier assembly uses the
  • Page 97 – -45. Transconductance and Cascode Stage; 0V). A gate resistor similar to R675 suppresses high frequency
  • Page 98 – 00V on them during normal
  • Page 99 – 00V supplies are turned off. Transistor Q606 forces the minimum
  • Page 102 – Serial Interface/Guard Crossing Section
  • Page 104 – 5V power supply range. Table 4-4 shows the signal name of the
  • Page 109 – Chapter 5; Calibration and Verification
  • Page 113 – static awareness; A Message From; Fluke Corporation
  • Page 115 – Chapter 6; Maintenance
  • Page 117 – Replace the line power fuse
  • Page 118 – To clean the air filter, refer to Figure 6-2 and proceed as follows:
  • Page 119 – General Cleaning; Cleaning; PCA’s
  • Page 120 – Procedures
  • Page 121 – Access Procedures; Turn off the POWER switch.
  • Page 123 – Perform the Initial Access Procedure.
  • Page 128 – -13. Accessing the High Voltage Output Transistors
  • Page 129 – Enabling Front or Rear Binding Posts; Turn over the 5725A so that the top is facing up.; -15. Enabling Front or Rear Binding Posts; Proceed as follows to change the current output location:
  • Page 130 – Reinstall the top cover.
  • Page 131 – Chapter 7; Troubleshooting
  • Page 133 – Diagnostics
  • Page 135 – Self Diagnostics
  • Page 136 – Normal at power-up, but trips out when entering current standby
  • Page 137 – Manual Tests for Fault Isolation; Proceed as follows to isolate the problem in these conditions:
  • Page 138 – Problem 3: Fault When Entering Voltage Operate; Proceed as follows to isolate the problem in this condition:; Problem 4: Fault When Entering Current Standby; Problem 5: Fault When Entering Current Operate; Proceed as follows to isolate a problem in this condition:
  • Page 139 – Testing the Power Supply By Itself; 0V mode. The high voltage amplifier may also be
  • Page 141 – Chapter 8; List of Replaceable Parts
  • Page 145 – Parts Lists
  • Page 181 – Chapter 9; Schematic Diagrams
  • Page 205 – Index
Loading the manual

®

5725A

Amplifier

Instruction Manual

PN 823435
January 1989
Rev. 7, 6/02

© 1993, 1996, 2002 Fluke Corporation, All rights reserved. Printed in U.S.A.

All product names are trademarks of their respective companies.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Table of Contents; Chapter

i Table of Contents Chapter Title Page 1 Introduction and Specifications........................................................ 1-1 1-1. Introduction .......................................................................................... 1-3 1-2. Where to Go From Here ..............................

Page 5 - Contents

Contents (continued) iii 4-43. Window Comparator ................................................................... 4-26 4-44. Input Clamp ................................................................................. 4-26 4-45. Transconductance and Cascode Stage ...................................

Page 7 - List of Tables; Table; AC Voltage Secondary Performance Specifications and Operating

v List of Tables Table Title Page 1-1. 5720A Series II DC Voltage Specifications: 99 % and 95 % Confidence Levels 1-7 1-2. 5700A Series II DC Voltage Specifications: 99 % and 95 % Confidence Levels 1-8 1-3. DC Voltage Secondary Performance Specifications and Operating Characteristics ..................

Other Fluke Models

All Fluke Other