Page 2 - Fluke Corporation, Hart Scientific Division
Fluke Corporation, Hart Scientific Division 799 E. Utah Valley Drive • American Fork, UT 84003-9775 • USA Phone: +1.801.763.1600 • Telefax: +1.801.763.1010 E-mail: [email protected] www.hartscientific.com Specifications subject to change without notice. • Copyright © 2008 • Printed in USA
Page 3 - Limited Warranty & Limitation of Liability
Limited Warranty & Limitation of Liability Each product from Fluke Corporation, Hart Scientific Division (“Hart”) is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year(s) for the Reference Thermometer. The warranty period b...
Page 4 - fect the validity or enforceability of any other provision.
DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this ...
Page 5 - Table of Contents
i Table of Contents 1 Before You Start .......................................................................1 1.1 Introduction ............................................................................................... 11.2 Standard Equipment ......................................................
Page 6 - Figures
1523, 1524 Thermometer Readout ii Figures Figure 1 Clamp-On Ferrite ................................................................................. 6Figure 2 Input/Output Connections - 1523 ........................................................ 9Figure 3 Input/Output Connections - 1524 ............
Page 7 - Tables
iii Tables Table 1 International Symbols ............................................................................ 4Table 2 1523 Input/Output Connections ............................................................ 9Table 3 1524 Input/Output Connections ..............................................
Page 9 - Before You Start; Introduction; AC Adapter, with power cord
Before You Start Standard Equipment 1 Before You Start 1 Introduction 1.1 The Reference Thermometer Readouts (1523, 1524) are designed to be reliable, stable, temperature measur- ing instruments that can be used in the field or laboratory. They offer accuracy, portability, and speed for near- ly eve...
Page 10 - Safety Information; Warning; Caution; identifies conditions; Warning; To avoid possible electric shock or personal injury:
1523, 1524 Thermometer Readout Safety Information 2 Safety Information 1.3 The Reference Thermometer is designed in accordance with EN 61010-1 {2nd Edition}, and CAN/CSA 22.2 No 61010.1-04. Use this instrument only as specified in this manual, otherwise the protection provided by the instrument may ...
Page 11 - 524 model, thermocouples can only be used on channel 1.; Cautions; Use the proper probes, function and range for your measurement.
Before You Start Safety Information 3 appears damaged or operates abnormally. Protection may be impaired. When in doubt, have the instrument serviced.Always use an isolated RTD or PRT (metal sheath isolated from lead wires). ● ● Make sure the battery door is closed and latched before you operate the...
Page 12 - Symbol
1523, 1524 Thermometer Readout Safety Information 4 Table 1 International Symbols Symbol Description Symbol Description AC (Alternating Current) PE Ground AC-DC Hot Surface (Burn Hazard) Battery Read the User’s Guide (Important Information) Complies with European Union directives Off DC On Double In...
Page 13 - CE Comments; EMC Directive; typical configuration with shielded RS-232 cables.; Immunity Testing; Using Clamp-On Ferrites
Before You Start Using Clamp-On Ferrites 5 CE Comments 1.4 EMC Directive 1.4.1 Hart Scientific’s equipment has been tested to meet the European Electromagnetic Compatibility Directive (EMC Directive, 2004/108/EC ). The Declaration of Conformity for your instrument lists the specific stan- dards to w...
Page 14 - probe cable; Emissions Testing; The instrument fulfills the limit requirements for Class B.
1523, 1524 Thermometer Readout Emissions Testing 6 Figure 1 clamp-on ferrite probe cable Clamp-On Ferrite Emissions Testing 1.6 The instrument fulfills the limit requirements for Class B. Low Voltage Directive (Safety) 1.7 In order to comply with the European Low Voltage Directive (2006/95/EC), Fluk...
Page 15 - Authorized Service Centers; Fluke Corporation; Model Number
Before You Start Authorized Service Centers 7 1.8 Authorized Service Centers Please contact one of the following authorized Service Center to coordinate service on your Fluke product: Fluke Corporation Hart Scientific Division Phone: +1.801.763.1600 Fluke Nederland B.V. Phone: +31-402-675300 Fluke I...
Page 17 - Setup; HOLD; Description
Quick Start Setup 9 Quick Start 2 Setup 2.1 SAVE NEXT HOME ENTER RESET TREND RECALL HOLD STATS ° C ° F SETUP mV RS 232 12 V DC 30 V MAX 1523 CALIBRATION THERMOMETER READOUT Figure 2 Input/Output Connections - 1523 1523 Input/Output Connections Table 2 No. Name Description 1 Serial Serial interface c...
Page 18 - Name
1523, 1524 Thermometer Readout Setup 10 SAVE NEXT HOME LOG RESET ENTER RECALL HOLD STATS ° C ° F SETUP TREND mV RS 232 12 V DC 30 V MAX T1 T 2 1524 CALIBRATION THERMOMETER READOUT Figure 3 Input/Output Connections - 1524 1524 Input/Output Connections Table 3 No Name Description 1 Serial Serial inter...
Page 20 - Key; STATS
1523, 1524 Thermometer Readout Setup 12 1523 Key Functions Table 4 No Key Description 1 Power on or off 2 Yellow Second or Special Function Key 3 Turns the backlight on or off 4 STATS 1st Press: MAX, 2nd Press: MIn, 3rd Press: AVE, 4th Press: STD DEV 5 ° C ° F Units, °C/°F 6 HOLD 1st press - Holds v...
Page 32 - Specifications; otherwise. All specifications assume a five minute warm up period.
1523, 1524 Thermometer Readout Specifications 24 Figure 13 1524 Menu (cont) Specifications 2.2 Specifications are based on a one year calibration cycle and apply from 13 °C to 33 °C unless stated otherwise. All specifications assume a five minute warm up period. General Specifications Table 6 Operat...
Page 34 - Ohms Range; Type
1523, 1524 Thermometer Readout Specifications 26 Ohms Measurement, Thermistor Table 9 Ohms Range Accuracy ± Ω, 4 Wire 200 Ω to 50 k Ω ± (0.01 % + 0.5 Ω ) 50 k Ω to 500 k Ω ± (0.03 %) Temperature Coefficient ( –10 °C to 13 °C , +33 °C to 60 °C): 0.002 %/°C + 0.1 Ω (0 Ω to 50 k Ω ) 0.06 %/°C + 0.1 Ω (...
Page 36 - Accuracy ±
1523, 1524 Thermometer Readout Specifications 28 Temperature, RTD Ranges, Table 11 and Accuracies (ITS-90) Accuracy ± ° C 4 Wire Probe ± 0.011 at –100 °C ± 0.015 at 0 °C ± 0.019 at 100 °C± 0.023 at 200 °C± 0.031 at 400 °C± 0.039 at 600 °C Resolution: 0.001°C (0.001°F) Temperature, Thermistor Table 1...