English Instructions: Operation and Features - FIRST FA-6405 - User Manual - Page 2

FIRST FA-6405
1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 1 – Cover and Language Index
  • Page 2 – English Instructions: Operation and Features
  • Page 3 – German Instructions: Bedienungsanleitung
  • Page 4 – Russian Instructions: Правила эксплуатации
  • Page 5 – Polish Instructions: Instrukcja obsługi
  • Page 6 – Serbian/Croatian/Bosnian Instructions
  • Page 7 – Latvian Instructions: Lietošanas pamācība
  • Page 8 – Lithuanian Instructions: Naudojimo instrukcija
  • Page 9 – Romanian Instructions: Manual de instrucțiuni
  • Page 10 – Bulgarian Instructions: Инструкция за работа
  • Page 11 – Ukrainian Instructions: Інструкція з експлуатації
  • Page 12 – French Instructions: Mode d'emploi
  • Page 13 – Spanish Instructions: Manual de instrucciones
  • Page 14 – Arabic Instructions: دليل الاستخدام
Loading the manual

INSTRUCTION MANUAL

INSTRUCTION

Please read this instruction carefully in order to use the scale correctly & keep the scale in good condition.

FEATURE

  • High accuracy strain-gauge sensor
  • Auto-off & manual off
  • Tare function
  • Overload indication
  • Low battery indication
  • Capacity (max) 5kg Division (d) 1g

HOW TO OPERATE

1. Remove the cover of battery compartment at the bottom of the scale. Insert 2 pcs. AAA batteries in proper polarity (not included). Close battery cover.

2. Place the scale on a hard & flat surface, ensure scale sit stable then put the bowl on the weighing platform.

3. Press button "ON/OFF" to turn on the scale. Wait for "0" to appear on LCD (about 2 seconds) as following:

. 0g

The scale is ready for weighing now!

4. "Kg/g" conversion: whenever you wish, you can press button "UNIT" to convert between Kg-g. When weighing, try to keep the weighing object to the centre of the bowl. Read the display when the reading is stable. The weight will be displayed in the following format:

12g 00 12g

ZERO " OR "TARE" FUNCTION

To weigh different loads consecutively without removing loads from the scale. Put first Load on the scale, get weight reading. Press Z/T button to reset the LCD reading to "0" bevor adding next load.

  • Condition 1: When total sum of all loads on scale ≤ 4% of scale`s max. weight capacity. (4%=80g when capacity is 2kg; 200g when capacity is 5kg) LCD will show "0g" each time Z/T is pressed. Icon "ZERO" will show on lower left corner of LCD, indicating "ZERO" function is active. Max. weight capacity remains unchanged.
  • Condition 2: When total sum of all loads on scale > 4% of scale`s max. weight capacity. (4%=80g when capacity is 2kg; 200g when capacity is 5kg) LCD will show "0g" each time Z/T is pressed. Icon "TARE" will show on lower left corner of LCD, indicating "TARE" function is active. Max. weight capacity is reduced by total weight of all loads.

AUTO-OFF/MANUAL OFF

1. When the scale first turned on and on weighing activity taking place within 2 minutes, it will be automatically turned off.

2. If after some weighing activities taken place, the scale then left sitting idle it will be automatically turned off in 2 minutes.

3. You can also manually turn off the scale whenever needed by pressing button "ON/OFF".

CAUTION NOT TO OVERLOAD

The maximum capacity of your scale is indicated on the display panel. If the loading exceeds the capacity by 1%, the display will start to indicate warning message "ERR". CAUTION: SHOULD BE TAKEN NOT OT OVERLOAD TO EXCEED THE CAPACITY OF THE SCALE. EXCEEDING THIS MAY CAUSE DAMAGE TO THE SCALE.

LOW BATTERY INDICATION

When battery is low, "LO" will appear on the LCD

Lo PLEASE REPLACE WITH NEW BATTERY.

CARE TAKING AND TROUBLE SHOOTING

1. The scale is a precision instrument. Please avoid heavy striking, do not keep it laden with weights for a long period.

2. Do not press button heavily or with sharp object such as pen-tip.

3. When you switch on the scale after pressing the button "ON/OFF", and find nothing appear on the LCD screen. Please ensure & check the battery is installed and well connected. Or if battery is already well installed, it may be low in power, replace it with new one.

4. Do not use any chemical or abrasive solvent to clean the scale. It is recommended to use soft damp cloth to gently wipe clean the scale once in a while. DO NOT IMMERSE THE SCALE IN WATER.

5. Always keep the scale far away from heat, I.E. stove, to keep the button from aging which will lead to loss of function.

6. When the scale is under weighing, keep away from electromagnetic interference (EMI) I.E. mobile phone, to avoid unwanted interference to the accuracy.

7. Please remove the battery if it is not going to be used for an extended period.

8. This scale is only for domestic use.

Environment friendly disposal

You can help protect the environment! Please remember to respect the local regulations: hand in the non-working electrical equipments to an appropriate waste disposal center.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for FIRST FA-6405

Summary

Page 1 - Cover and Language Index

Title page displaying the product name in multiple languages, certification logos, and a language index with page numbers for easy navigation.

Page 2 - English Instructions: Operation and Features

Detailed guide on using the scale: high-accuracy sensor, auto-off, tare function, step-by-step operation, overload and battery warnings, care tips, and disposal.

Page 3 - German Instructions: Bedienungsanleitung

German version covering features, usage, zero/tare function, shutdown modes, overload warning, battery indicator, safety instructions, and disposal.

Tips

  • Always place the scale on a hard, flat surface for accurate measurements.
  • Use the tare function to weigh multiple ingredients sequentially without removing the bowl.
  • Do not exceed the maximum capacity of 5 kg to avoid damage.
  • Keep the scale away from heat sources and electromagnetic interference, such as mobile phones.
  • Clean the scale with a soft damp cloth and never immerse it in water.
  • Remove the batteries if the scale is not in use for an extended period to prevent leakage.