Extron MLC 62 RS EU - Manual

Extron MLC 62 RS EU

Extron MLC 62 RS EU – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – MLC 62 EU and MLC 62 MK • Setup Guide (Continued); hold the MLC with its circuit board against the; Attach the metal mounting bracket to the junction box.; Connect a display device or; both; devices to common; IR Emitter
  • Page 3 – Product Category; — Connect a switch; Rx; MLC 60 Series Configuration Program Help File; MLC RS EU or MK Rear Panel; Power Supply
  • Page 4 – Test the system; to ensure that the MLC is functioning; Mounting the MLC 62 EU in a Raceway; Mount the electrical box in the raceway.; out; (away from the spacer and
Loading the manual

Product Category

IMPOR

TANT

:

Go to www

.extron.com for the

complete user guide and installation

instructions befor

e connecting the

product to the power sour

ce.

MLC 60 Series • Setup Guide

for the MLC 62 RS EU and the MLC 62 RS MK

The Extron MLC 62 RS EU and the MLC 62 RS MK
are keypad controllers for use in classrooms and
meeting facilities. The EU model attaches to a
single size European electrical junction box with a
60 mm mounting center; the MK model mounts to
a single size MK junction box. The controllers have
backlit soft touch buttons and can control common
AV functions, including power, input switching, and
volume. Both models provide RS-232 serial and IR
ports for universal display control. A digital input
and two relays enable monitoring and controlling
of other devices in the room. Both models have
six-button and eight-button options.

NOTES:

Installation and service must be performed by authorized personnel only.

For full installation, configuration, and operation details, see the

MLC 60 Series User Guide

, available at

www.extron.com

.

Installation Steps

1.

Prepare the installation site.

The MLC 62 EU and MK controllers can be installed in a
standard EU or MK one-gang electrical wall box:

a.

Install the electrical box, following the instructions
provided with it.

CAUTION:

Ensure that the junction box is

properly grounded.

b.

Prepare and pull the cables through the electrical
box.

2.

(Optional) Change the faceplate and buttons as needed.

a.

Remove the faceplate from the MLC module as follows:

i.

On the right and left edges of the faceplate are two pairs of slots, into
which two small tabs on either side of the MLC fit. Insert the flat end
of a small screwdriver into each side slot (as shown at right) and press
inward until the tab is released from its slot.

ii.

Lift the faceplate off the MLC circuit board.

b.

If desired, replace the buttons in the faceplate as follows:

i.

From the front of the faceplate, press the button membrane to be
replaced backward through its faceplate openings until it comes free.
If replacing the faceplate, repeat this step until all the buttons are
removed.

ii.

On the back of the faceplate, set the new button membrane at the
desired location, with the two pegs in the upper-left and lower-right
corners of the membrane in the faceplate holes at opposite corners of the
row (see the illustrations at left and at right). Press the pegs and buttons
of the membrane into the faceplate.

iii.

Repeat step

2

b

as needed.

1

Extron

VOLUME

DISPLAY

ON

OFF

VIDEO

PC

MUTE

LAPTOP

Extron

VOLUME

DISPLAY

ON

OFF

LAPTOP

MUTE

PC

VIDEO

MLC 62 RS EU

MLC 62 RS MK

Rear Panel

Left Side Panel

RELAYS

N/O

PWR

12 V

0.4 A max

HOST/

CONFIG

DIG

IT

AL

IN

PU

T

+

Tx

Rx

1

Tx

Tx/

IR

1

2

C

1

2

R

PORT A

RS-232

PORT B

IR/ S

Peg

Peg

Slot

VOLUME

DISPLA

Y

PC

VIDE

O

OF

F

ON

MUTE

LAPTOP

MUTE

LAPTO

P

Pegs (2)

Button
Membrane

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MLC 62 EU and MLC 62 MK • Setup Guide (Continued); hold the MLC with its circuit board against the; Attach the metal mounting bracket to the junction box.; Connect a display device or; both; devices to common; IR Emitter

MLC 62 EU and MLC 62 MK • Setup Guide (Continued) c. Reattach or replace the faceplate as follows (see the illustration at right): i. Making sure that both the MLC and the faceplate are upright , hold the MLC with its circuit board against the back of the faceplate, aligning the two tabs on each sid...

Page 3 - Product Category; — Connect a switch; Rx; MLC 60 Series Configuration Program Help File; MLC RS EU or MK Rear Panel; Power Supply

Product Category z Digital Input port — Connect a switch or sensor to this port to control other devices in the room that are connected to the MLC serial, IR, or relay ports. The port monitors the high and low states of the connection between the switch or sensor and the connected device. For the vo...

Page 4 - Test the system; to ensure that the MLC is functioning; Mounting the MLC 62 EU in a Raceway; Mount the electrical box in the raceway.; out; (away from the spacer and

68-2166-51 Rev. A 03 12 Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.863.1794 +1.714.491.1517 FAX +1.919.863.1797 FAX Extron Europe+800.3987.6673 (Inside Europe Only)+31.33.453.4040 +31.33.453.4050 FAX Extron Asia+800.7339.8766...

Other Extron Models

All Extron Other