Page 3 - INTERTEK TESTING SERVICES; ii; MEASUREMENT/TECHNICAL REPORT
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO ii MEASUREMENT/TECHNICAL REPORT Evenflo Company, Inc. - MODEL: 6461300 FCC ID: EHK900646TEVENFLO This report concerns (check one:) Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Defe...
Page 4 - iii; Table of Contents
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO iii Table of Contents 1.0 General Description ........................................................................................................2 1.1 Product Description............................................................................
Page 5 - List of attached file
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO iv List of attached file Exhibit type File Description filename Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated Emission config photos.doc Test Setup Photo Conducted Emission confi...
Page 7 - General Description; Product Description
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 2 1.0 General Description 1.1 Product Description The Equipment Under Test (EUT) is a Transmitter operating at 927.2MHz-927.8MHz consist of 4 frequencies. The EUT is powered by 120VAC to 6VDC 150mA non-removable Adaptor. It is a baby unit of RF Bab...
Page 8 - T est Methodology; Justification; of this Application.
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 3 1.3 T est Methodology Both AC mains line-conducted and radiated emission measurements were performed according to the procedures in ANSI C63.4 (1992). All measurements were performed in Open Area Test Sites. Preliminary scans were performed in th...
Page 10 - System Test Configuration
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 5 2.0 System Test Configuration 2.1 Justification The system was configured for testing in a typical fashion (as a customer would normally use it), and in the confines as outlined in ANSI C63.4 (1992). The EUT was powered from 120VAC 60Hz input, 6V...
Page 11 - Tommy Leung
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 6 2.4 Equipment Modification Any modifications installed previous to testing by Evenflo Company, Inc. will be incorporated in each production model sold/leased in the United States. No modifications were installed by Intertek Testing Services. 2.5 ...
Page 13 - Emission Results
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 8 3.0 Emission Results Data is included worst case configuration (the configuration which resulted in the highest emission levels). A sample calculation, configuration photographs and data tables of the emissions are included.
Page 16 - Radiated Emission Configuration Photograph
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 11 3.2 Radiated Emission Configuration Photograph Wors t Case Radiated Emission a t 927.400 MHz For electronic filing, the worst case radiated emission configuration photograph is saved with filename: config photos.doc.
Page 17 - Radiated Emission Data
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 12 3.3 Radiated Emission Data The data on the following page lists the significant emission frequencies, the limit and the margin of compliance. Numbers with a minus sign are below the limit. Judgement: Passed by 1.9 dB TEST PERSONNEL: Signature Yv...
Page 18 - Table 1; Radiated Emissions; Negative value in the margin column shows emission below limit.
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 13 Company: Evenflo Company, Inc. Date of Test: October 27 -November 14, 2003 Model: 6461300 Mode: TX-Channel A Table 1 Radiated Emissions Frequency Reading Pre- Antenna Net Limit Margin Polarization Amp Factor at 3m at 3m (MHz) (dB µ V) (dB) (dB) ...
Page 19 - Conducted Emission Configuration Photograph
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 14 3.4 Conducted Emission Configuration Photograph Worst Case Line -Conducted Configuration For electronic filing, the worst case line-conducted configuration photograph are saved with filename: config photos.doc.
Page 20 - Conducted Emission Data
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 15 3.5 Conducted Emission Data For electronic filing, the graph and data table of conducted emission is saved with filename: conduct.pdf. Judgement: Passed by more than 20 d B TEST PERSONNEL: Signature Yvonne Leung, Engineer Typed/Printed Name Nove...
Page 22 - Equipment Photographs
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 17 4.0 Equipment Photographs For electronic filing, the photographs of the tested EUT are saved with filename: external photos.doc & internal photos.doc.
Page 24 - Product Labelling
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 19 5.0 Product Labelling For electronic filing, the FCC ID label artwork and the label location are saved with filename: label.pdf.
Page 26 - Technical Specifications
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 21 6.0 Technical Specifications For electronic filing, the block diagram and schematics of the tested EUT are saved with filename: block.pdf and circuit.pdf respectively.
Page 28 - Instruction Manual
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 23 7.0 Instruction Manual For electronic filing, a preliminary copy of the Instruction Manual is saved with filename: manual.pdf. This manual will be provided to the end -user with each unit sold/leased in the United States.
Page 30 - Miscellaneous Information
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 25 8.0 Miscellaneous Information This miscellaneous information includes details of the measured bandwidth, the test procedure and calculation of factors such as pulse desensitization and averaging factor.
Page 31 - Measured Bandwidth
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 26 8.1 Measured Bandwidth For electronic filin g, the plot shows the fundamental emission when modulated with 1kHz and 100 dBSPL, 10cm from the Microphone of EUT and unmodulated is saved with filename: bw.pdf. From the plot, the field strength of a...
Page 32 - Discussion of Pulse Desensitization
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 27 8.2 Discussion of Pulse Desensitization The determination of pulse desensitivity was made in accordance with Hewlett Packard Application Note 150 -2, Spectrum Analysis ... Pulsed RF. Pulse desensitivity is not applicable for this device since th...
Page 33 - Calculation of Average Factor
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 28 8.3 Calculation of Average Factor The emission limits are specified using spectrum analyzers or receivers which incorporate quasi-peak detectors. Typical measurements are made using peak detectors, however, emissions which approach the respectiv...
Page 34 - Emissions Test Procedures
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 29 8.4 Emissions Test Procedures The following is a description of the test procedure used by Intertek Testing Services in the measurements of transmitters operating under Part 15, Subpart C rules. The test set-up and procedures described below are...
Page 35 - The EUT is warmed up for 15 minutes prior to the test.
INTERTEK TESTING SERVICES FCC ID: EHK900646TEVENFLO 30 8.4 Emissions Test Procedures (cont'd) The EUT is warmed up for 15 minutes prior to the test. AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental emission field strength is recorded. If battery powered, a new...