  • Page 2 – TABLE OF CONTENTS; PILOT WILL NOT STAY LIGHT; Sherwood
  • Page 5 – B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT
  • Page 6 – To remove pilot injector; Sherwood Industries Ltd.
  • Page 7 – SUPPLY PRESSURES
  • Page 12 – MAIN BURNERS WILL NOT LIGHT CON’T.
  • Page 20 – B) DIRECT VENT MODELS
  • Page 21 – ALL MODELS
  • Page 23 – STEP BY STEP SERVICE INSTRUCTIONS; in
  • Page 24 – CLEANING THE APPLIANCE; Only use a very soft cloth an a non abrasive cleaner,; use any alcohol’s, mineral; DO NOT
  • Page 25 – improper
Loading the manual


FOR INSTALLERS AND SERVICE TECHNICIANS ONLY

GAS

FIREPLACE

SERVICE

MANUAL

Sherwood Industries Ltd. Duplication of this document is prohibited. All rights reserved.

August 2003 C-10100

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; PILOT WILL NOT STAY LIGHT; Sherwood

This is a service guide designed by SHERWOOD INDUSTRIES LTD. We hope this manual will assist you to identify and correct operational concerns you might experience in all ENVIROGAS appliances. This service guide is designed for TRAINED SERVICE TECHNICIANS AND INSTALLERS.This guide is NOT to be used b...

Page 5 - B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT

B) PIEZO IGNITOR OK BUT PILOT WILL STILL NOT LIGHT Make sure all gas lines have been connected with no leaks. Make sure that the gas is “ON” (NG) Natural gas and (LP) Propane tanks are full. Make sure the appliance service valve is in the “ON” position. SEE PAGE 4 FIGURE 3. Test to make sure there i...

Page 6 - To remove pilot injector; Sherwood Industries Ltd.

EXPLODED VIEW S.I.T PILOT ASSEMBLY To remove pilot injector : Remove the two screws that hold the pilot assembly to the burner control assembly. Lift the assembly straight up being careful not to damage any components. Using a 10 mm wrench undo the securing nut on pilot tubing and pull tubing down t...