Page 3 - Notice; Documentation
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determ...
Page 4 - Regulatory Compliance Information
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and ...
Page 5 - Hazardous Substances
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibilidad Electromágnetica ...
Page 6 - ѻક䇈ᯢк䰘ӊ; Supplement to Product Instructions; ᳝↦᳝ᆇ⠽䋼ܗユ
iv ѻ ѻક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U ⒈㘨㣃 3%% ⒈Ѡ㣃䝮 3%'( 䞥ሲ䚼ӊ (Metal Parts) h ƻ ƻ h ƻ ƻ ⬉䏃ഫ ( Circuit Modules) h ƻ ƻ h ƻ ƻ ⬉㓚ঞ⬉㓚㒘ӊ ( Cables & Cable Assemblies) h ƻ ƻ h ƻ ƻ ล᭭㘮ড়⠽䚼ӊ (Plastic and Polymeric parts...
Page 8 - Declaration of Conformity
vi Declaration of Conformity Application of Council Directive(s): 89/336/EEC73/23/EEC Manufacturer ’s Name: Enterasys Networks, Inc. Manufacturer ’s Address: 50 Minuteman Road Andover, MA 01810 USA European Representative Address: Enterasys Networks, Ltd. Nexus House, New...
Page 9 - Firmware License Agreement; BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
vii Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on behalf of itself ...
Page 11 - AUDIT
ix 8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i...
Page 13 - Contents; About This Guide
xi Contents About This Guide Who Should Use This Guide ............................................................................................................... xvHow to Use This Guide ................................................................................................................
Page 14 - Chapter 4: Troubleshooting
xii Connecting to COM Port for Local Management ............................................................................. 3-20 What Is Needed ......................................................................................................................... 3-20Connecting to an IBM PC or C...
Page 15 - Figures
xiii Figures 1-1 4H4282-49, 4H4283-49, and 4H4203-72 DFE-Gold Modules......................................................1-4 1-2 4H4202-72 and 4H4284-49 DFE-Gold Modules ..........................................................................1-5 3-1 Examples, Slot Numbers/Module Placement in Mat...
Page 16 - Tables
xiv Tables 3-1 Contents of DFE-Gold Module Carton..........................................................................................3-2 4-1 LANVIEW LEDs............................................................................................................................4-5 4-1 Troublesh...
Page 17 - Who Should Use This Guide; Important Notice; Elektrischer Gefahrenhinweis:
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xv About This Guide This guide provides an overview, installation and troubleshooting instructions, and specifications for the Enterasys Matrix™ DFE ‐ Gold 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, ...
Page 18 - How to Use This Guide; Refer to
How to Use This Guide xvi About This Guide How to Use This Guide This preface provides an overview of this guide and the DFE ‐ Gold Series manual set, and a brief summary of each chapter; defines the conventions used in this document; and ins...
Page 19 - Conventions Used in This Guide; Lowercase
Conventions Used in This Guide Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide xvii Conventions Used in This Guide The following conventions are used in this guide: Lowercase x : Indicates the general use of an alphanumeric character (for exam...
Page 20 - Getting Help
Getting Help xviii About This Guide Getting Help For additional support related to the modules or this document, contact Enterasys Networks using one of the following methods: Before contacting Enterasys Networks for technical support, have the follo...
Page 21 - Introduction; Overview of DFE-Gold Series Capabilities
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-1 1 Introduction This chapter provides an overview of the DFE ‐ Gold module capabilities, and introduces the 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, 4H4202 ‐ 72, and 4H4284 ‐ 49 DFE ‐ Gold m...
Page 26 - Connectivity; Figure 1
Connectivity 1-6 Introduction Connectivity 4H4282-49 Depending on how the 4H4282 ‐ 49 ( Figure 1 ‐ 1 ) is configured, it can support up to: • 48, 10BASE ‐ T/100BASE ‐ TX switched ports connected through 48 fixed, RJ45 front ‐ panel connectors, or • 48, ...
Page 27 - Management; Switch Configuration Using WebView; Standards Compatibility; Secure
Management Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 1-7 Management Management of the module can be either in ‐ band or out ‐ of ‐ band. In ‐ band remote management is possible using Telnet, Enterasys Networks’ NetSight ® management ...
Page 28 - LANVIEW Diagnostic LEDs
LANVIEW Diagnostic LEDs 1-8 Introduction • Network Services are logical groups of Classification Rules that identify specific networked applications or services. Users may be permitted or denied access to these services based on their role wi...
Page 29 - Network Requirements; Cabling
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide 2-1 2 Network Requirements Before installing the module, review the requirements and specifications referred to in this chapter concerning the following: • 10BASE ‐ T Network (page 2 ‐ 1) • 100BA...
Page 31 - Installation
Matrix DFE-Gold Series Modules Hardware Installation Guide 3-1 3 Installation This chapter provides the instructions to install the 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, 4H4202 ‐ 72, and 4H4284 ‐ 49 DFE ‐ Gold modules. Follow the order of the sections listed ...
Page 32 - Installation Site Requirement; Table 3; Table 3-1 Contents of DFE-Gold Module Carton
Installation Site Requirement 3-2 Installation Installation Site Requirement The DFE ‐ Gold module must be installed in a Matrix E7, N1, N3, N5, or N7 chassis located in a Restricted Access Location (RAL). This location should only be accessible ...
Page 33 - Installing Optional Network Expansion Module; Figure 3
Installing Optional Network Expansion Module Matrix DFE-Gold Series Modules Hardware Installation Guide 3-3 Installing Optional Network Expansion Module A Phillips screwdriver is required to install an optional network expansion module into the 4H4282 ‐ 49, 4H4283 ‐ 49,...
Page 34 - set license; “Related
DFE Module Placement and Installation Rules 3-4 Installation To ensure proper operation of the system, consider the following examples and rules for module placement in either chassis. Example 1 ( Figure 3-1 , A) Shows one module installed in the chass...
Page 35 - DO; Installing Module into a Chassis; “Preparation”
Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-5 Example 3 ( Figure 3-1 , C) Shows the primary management module missing from slot 1. As long as the module installed in slot 2 is designated as a redundant ma...
Page 36 - Preparation; “Getting; Installing Module into Matrix E7 or N7 Chassis
Installing Module into a Chassis 3-6 Installation Preparation 1. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow for cooling. (Save the blank plate ...
Page 39 - Installing Module into Matrix N1, N3, or N5 Chassis
Installing Module into a Chassis Matrix DFE-Gold Series Modules Hardware Installation Guide 3-9 Installing Module into Matrix N1, N3, or N5 Chassis A DFE ‐ Gold module can be installed in any available chassis slot (1 through 3) in the Matrix N3 chassis or slots ...
Page 40 - Connecting to the Network
Connecting to the Network 3-10 Installation Connecting to the Network For connecting unshielded twisted pair (UTP) segments from the network or other devices, refer to • Connecting UTP Cables to 4H4282 ‐ 49 or 4H4202 ‐ 72 (page 3 ‐ 11) • Connecting UTP C...
Page 42 - Figure 3-4 Connecting a Twisted Pair Segment With RJ45 Connector
Connecting to the Network 3-12 Installation 3. Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing amber, blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) LED is not blin...
Page 47 - Figure 3-10 Connection Using Optional RJ21 Angle Adapter
Connecting to the Network Matrix DFE-Gold Series Modules Hardware Installation Guide 3-17 Figure 3-10 Connection Using Optional RJ21 Angle Adapter 1 RJ21 angle adapter 5 Retaining clips 2 RJ21 port connector 6 GROUP SELECT button 3 Retaining screws 7 Example showing how multiple cables would be arra...
Page 50 - Connecting to COM Port for Local Management; What Is Needed
Connecting to COM Port for Local Management 3-20 Installation 1. Verify that a link exists by checking that the port RX LED is ON (flashing amber, blinking green, or solid green). If the RX LED is OFF and the TX LED is not blinking ...
Page 51 - Connecting to an IBM PC or Compatible Device; Parameter
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-21 With a UTP straight ‐ through cable and RJ45 ‐ to ‐ DB25 female adapter, you can connect products equipped with an RJ45 COM port to a VT series te...
Page 52 - Connecting to a VT Series Terminal; Figure 3-12 Connecting an IBM PC or Compatible
Connecting to COM Port for Local Management 3-22 Installation Connecting to a VT Series Terminal To connect a VT Series terminal to an Enterasys Networks DFE ‐ Gold module COM port ( Figure 3 ‐ 13 ), use a UTP straight ‐ through cable with RJ45 connectors an...
Page 53 - Connecting to a Modem; Figure 3-13 Connecting a VT Series Terminal
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-23 When these parameters are set, the Local Management password screen will display. Refer to the Enterasys Matrix DFE ‐ Gold Series Configuration Guide ...
Page 55 - Adapter Wiring and Signal Assignments; COM Port Adapter Wiring and Signal Diagram
Connecting to COM Port for Local Management Matrix DFE-Gold Series Modules Hardware Installation Guide 3-25 Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive (RX) 4 Red 3 Transmit (TX) 5 Green 5 Ground (GRD) 2 Orange 7...
Page 56 - Completing the Installation; Completing the Installation of a New System; Modem Port Adapter Wiring and Signal Diagram
Completing the Installation 3-26 Installation Completing the Installation Completing the DFE module installation depends on if the module is being installed in: • a new DFE module system (refer to “Completing the Installation” on page 3 ‐ 26), or • a...
Page 57 - First-Time Log-In Using a Console Port Connection; rw
Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-27 First-Time Log-In Using a Console Port Connection Start the Command Line Interface (CLI) from the module’s local console port as follows: 1. Connect a terminal to the local...
Page 58 - admin
Completing the Installation 3-28 Installation Completing the Installation of a DFE-Gold Module in an Existing System In an established DFE ‐ Gold module system, • a DFE ‐ Gold module is already established as the management module, • the passwords have already been ...
Page 59 - Logging in with an Administratively-Configured User Account; set system login; set
Completing the Installation Matrix DFE-Gold Series Modules Hardware Installation Guide 3-29 Logging in with an Administratively-Configured User Account If the device’s default user account settings have been changed, proceed as follows: 1. At the login prompt, enter ...
Page 61 - Troubleshooting; Using LANVIEW
Matrix DFE-Gold Series Modules Hardware Installation Guide 4-1 4 Troubleshooting This chapter provides information concerning the following: • Using LANVIEW (page 4 ‐ 1) • Troubleshooting Checklist (page 4 ‐ 7) • Overview of DFE ‐ Gold Module Shutdown Procedure (page ...
Page 62 - Figure 4
Using LANVIEW 4-2 Troubleshooting Viewing Receive/Transmit Activity on 4H4282-49, 4H4283-49, and 4H4203-72 On the 4H4282 ‐ 49, 4H4283 ‐ 49, and 4H4203 ‐ 72 you can view the receive and transmit activity on the RX and TX LEDs. However, only one group of...
Page 64 - Viewing the Receive and Transmit Activity on 4H4284-49
Using LANVIEW 4-4 Troubleshooting Viewing the Receive and Transmit Activity on 4H4284-49 On the 4H4284 ‐ 49 DFE ‐ Gold module, you can view the receive and transmit activity on the RX and TX LEDs. However, only one group of 12 ports may be viewed...
Page 65 - Table 4-1 LANVIEW LEDs
Using LANVIEW Matrix DFE-Gold Series Modules Hardware Installation Guide 4-5 Table 4-1 LANVIEW LEDs LED Color State Recommended Action MGMT None Off . This module is NOT the Management Module. None. Green Solid . This module is the designated Management Module. None. Amber Flashing . This is a tempo...
Page 66 - LED
Using LANVIEW 4-6 Troubleshooting RX(Receive) None No link . No activity. Port enabled or disabled. None. Green Solid . Link present, port enabled, no traffic is being received by the interface. None. Amber Flashing . Link present, port enabled, traffic is being received by the interface. Rate of fl...
Page 67 - Troubleshooting Checklist; Table 4; Table 4-1 Troubleshooting Checklist
Troubleshooting Checklist Matrix DFE-Gold Series Modules Hardware Installation Guide 4-7 Troubleshooting Checklist If the module is not working properly, refer to Table 4 ‐ 1 for a checklist of problems, possible causes, and recommended actions to resolve ...
Page 68 - Problem
Troubleshooting Checklist 4-8 Troubleshooting Port(s) goes into standby for no apparent reason. Loop condition detected. Verify that Spanning Tree is enabled. Refer to the Enterasys Matrix DFE-Gold Series Configuration Guide for the instructions to set the type of STA. Review the network design and ...
Page 69 - Overview of DFE-Gold Module Shutdown Procedure
Overview of DFE-Gold Module Shutdown Procedure Matrix DFE-Gold Series Modules Hardware Installation Guide 4-9 Overview of DFE-Gold Module Shutdown Procedure The DFE ‐ Gold module s installed in a Matrix N3 or Matrix N7 chassis are interdependent and operate under a ...
Page 70 - Last Resort Shutdown Procedure Using OFFLINE/RESET Switch; the
Overview of DFE-Gold Module Shutdown Procedure 4-10 Troubleshooting Recommended Shutdown Procedure Using OFFLINE/RESET Switch Before pulling a DFE ‐ Gold module out of a chassis, press or tap on its OFFLINE/RESET switch for less than 1 second. Its CPU LED ...
Page 71 - Specifications; DFE-Gold Module Specifications; Table A-1 Specifications
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-1 A Specifications This appendix provides information about the following: • DFE ‐ Gold Module Specifications (page A ‐ 1) • COM Port Pinout Assignments (page A ‐ 3) • Regulatory Compliance (page A ‐...
Page 72 - Chassis Backplane Connectivity; Item
DFE-Gold Module Specifications A-2 Specifications 4H4203-72 Ports 1 through 72 Seventy-two, 10BASE-T/100BASE-TX compliant ports through six RJ21 connectors. 4H4202-72 Ports 1 through 72 Seventy-two, 10BASE-T/100BASE-TX compliant ports through 72 RJ45 connectors. 4H4284-49 Ports 1 through 48 Forty-ei...
Page 73 - COM Port Pinout Assignments; Table A
COM Port Pinout Assignments Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-3 COM Port Pinout Assignments The COM port is a serial communications port for local access to Local Management. Refer to Table A ‐ 2 for the COM port pin as...
Page 74 - Regulatory Compliance; Table A-3 Compliance Standards
Regulatory Compliance A-4 Specifications Regulatory Compliance The 4H4282 ‐ 49, 4H4283 ‐ 49, 4H4203 ‐ 72, 4H4202 ‐ 72, 4H4284 ‐ 49, and 7G ‐ 6MGBIC meet the safety and electromagnetic compatibility (EMC) requirements listed in Table A ‐ 3 : Table A-3 Compliance St...
Page 75 - Mode Switch Bank Settings; Required Tools
Matrix DFE-Gold Series Modules Hardware Installation Guide B-1 B Mode Switch Bank Settings and Optional Installations This appendix covers the following items: • Required Tools (page B ‐ 1) • Setting the Mode Switches (page B ‐ 2) • Memory Locations and Replacement Proc...
Page 76 - Setting the Mode Switches; Figure B
Setting the Mode Switches B-2 Mode Switch Bank Settings and Optional Installations Setting the Mode Switches Figure B ‐ 1 and Figure B ‐ 2 show the location of the mode switches and the switch settings for normal operation. These switches are set at the ...
Page 79 - Memory Locations and Replacement Procedures; Location of DIMM and DRAM SIMM Memory Modules
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-5 Memory Locations and Replacement Procedures In the event that the Dual In ‐ line Memory Module (DIMM) or DRAM Single In ‐ line Memory Module (SIMM) (FLASH me...
Page 80 - À Á
Memory Locations and Replacement Procedures B-6 Mode Switch Bank Settings and Optional Installations Figure B-6 DIMM and DRAM SIMM Locations (4H4203-72) 1 DRAM SIMM 2 DIMM 3 Main PC board Figure B-7 DIMM and DRAM SIMM Locations (4H4202-72) 1 DRAM SIMM 2 DIMM 3 Main PC board  À Á G R O U P 1 G R O U...
Page 81 - and; Removing the DRAM SIMM
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-7 DIMM Replacement Procedure (4H4282-49 and 4H4283-49) To remove and replace the DRAM SIMM on the 4H4282 ‐ 49 or 4H4283 ‐ 49, refer to Figure B ‐ 8 and Figure B ‐ ...
Page 83 - or
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-9 Removing the DRAM SIMM from 4H4203-72 To remove the existing DRAM SIMM, proceed as follows: 1. Locate the DRAM SIMM connector on the main PC board. Refer b...
Page 86 - DIMM Replacement Procedure (All DFE Modules); Removing the DIMM; Figure B-13 Removing the Existing DIMM
Memory Locations and Replacement Procedures B-12 Mode Switch Bank Settings and Optional Installations DIMM Replacement Procedure (All DFE Modules) In the event that the DIMM needs to be replaced, the following sections explain how to remove and install the DIM...
Page 87 - Installing the DIMM; Figure B-14 Installing the DIMM
Memory Locations and Replacement Procedures Matrix DFE-Gold Series Modules Hardware Installation Guide B-13 Installing the DIMM To install a DIMM, refer to Figure B ‐ 14 and proceed as follows: 1. Insert the DIMM down between the connector fingers. 2. Pivot the ...
Page 89 - Index; Numerics
Index-1 Index Numerics 100BASE-FX connections 3-18 requirements 2-2 100BASE-TX connections 3-11 requirements 2-2 10BASE-T connections 3-11 , 3-15 requirements 2-1 4H4202-72 introduction to 1-3 4H4203-72 introduction to 1-3 4H4282-49 introduction to 1-2 4H4283-49 introduction to 1-2 4H4284-49 introdu...