Page 3 - ELITE Sensors; Contents
iii IECEx Zone 1 Installation Instructions ELITE Sensors IECEx Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 F-Series, H-Series, R-Series, and Model CNG050 Sensors IECEx Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Model 220...
Page 4 - Micro Motion Sensors
iv IECEx Zone 2 Installation Instructions Model 2400S Transmitters IECEx Zone 2 Installation Instructions . . . . . . . . . . . . . . . . . . . . . 69 Model 2200S Transmitters IECEx Zone 2 Installation Instructions . . . . . . . . . . . . . . . . . . . . . 77 Micro Motion Sensors IECEx Zone 2 Instal...
Page 10 - Subject and type
ELITE Sensors 2 IECEx Installation Instructions (EB-20005444) 1) Subject and type Sensor type CMF*** ************ Instead of the asterisks (*), letters and numerals will be inser ted which indicate the following modifications: Marking without influence to the type of protection Letter for electronic...
Page 11 - Description
ELITE Sensors IECEx Installation Instructions (EB-20005444) 3 2) Description The flow sensor, in combination with a transmitter, is used for flow measurement. The flow sensor, which consists of magnetically excited oscillating tubes, contains as electrical components coils, resistors, temperature se...
Page 14 - Parameters; IIC
ELITE Sensors 6 IECEx Installation Instructions (EB-20005444) Supplement 5 covers: • Approval code “7” for CMF100/200/300/400/HC3 sensors for gas group IIC indicating construction and temperatures exactly as previously indicated by CIC A4. • Removed CMF800 and CMF800A, B, C, and E sensors. • Added e...
Page 20 - IIB
ELITE Sensors 12 IECEx Installation Instructions (EB-20005444) 3.1.4.3) Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. The use of the sensor at an ambient temperature higher than +55°C is possible, provided that the ambient temperature does ...
Page 45 - Marking
ELITE Sensors IECEx Installation Instructions (EB-20005444) 37 Note 1: Use the above graph to determine the temperature class for a given fluid and ambient temperature. The use of the sensor at higher ambient temperatures is possible, since the electronics are mounted min. 1 meter away from the sens...
Page 49 - Special conditions for safe use / Installation instructions
ELITE Sensors IECEx Installation Instructions (EB-20005444) 41 5) Special conditions for safe use / Installation instructions 5.1) By mounting the sensor type CMF********(J or U)****** directly to the transmitter 22**S********** the use of the unit will be modified according to the following table: ...
Page 59 - IECEx Installation Instructions
25 F-Series, H-Series, R-Series, and Model CNG050 Sensors IECEx Installation Instructions Subject: Equipment type Sensor type F*** *******I***** Sensor type H*** *******I***** Sensor type R*** *******I***** Sensor type CNG050*******I**** Manufactured and submitted for examination Micro Motion, Inc. ...
Page 89 - Transmitter to sensor with enhanced core processor
IECEx Installation Instructions, 4-wire 55 Model 1700/2700 to core processor Transmitter to sensor with enhanced core processor
Page 90 - Model 2750 to core processor
56 IECEx Installation Instructions, 4-wire Model 2750 to core processor Transmitter to sensor with enhanced core processor This unit is provided with an internal and external terminal forsupplementary bonding connection. This terminal is for use wherelocal codes or authorities permit or require such...
Page 91 - Transmitter to CMF sensors
IECEx Installation Instructions, 4-wire 57 Model 1700/2700 to core processor Transmitter to CMF sensors
Page 99 - Model 2750 with configurable I/O
IECEx Installation Instructions, Outputs 65 Model 2750 with configurable I/O
Page 103 - IECEx Zone 2 Installation Instructions; Ex nAC II T5
69 Model 2400S Transmitters IECEx Zone 2 Installation Instructions Subject: Equipment type Transmitter type 24********3**** Manufactured and submitted for examination Micro Motion, Inc. Address Boulder, Co. 80301, USA Basis for examination: Annex II of Directive 94/9/EC Standard basis IEC 60079-15:2...
Page 106 - Electrical Parameters
Model 2400S Transmitters 72 IECEx Installation Instructions: Zone 2 (EB-20004453) The 24****D******** is a non-sparking device (Ex n A) containing within the encapsulation a sealed relay (Ex n C). This relay is used to software select the internal termination impedance for the Profibus DP communicat...
Page 111 - Ex nA II T4
77 Model 2200S Transmitters IECEx Zone 2 Installation Instructions Subject: Equipment type Transmitter type 2200S*****3**** Manufactured and submitted for examination Micro Motion, Inc. Address Boulder, Co. 80301, USA Standard basis IEC 60079-15:2005 Non-sparking ´n´ Code for type of protection Ex n...
Page 148 - Micro Motion Inc. USA; Micro Motion Europe
Micro Motion Inc. USA Worldwide Headquarters 7070 Winchester CircleBoulder, Colorado 80301T +1 303-527-5200+1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process ManagementNeonstraat 16718 WX EdeThe NetherlandsT +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion Japan Emerson Proc...