Emerson GXT3 - Manual

Emerson GXT3

Emerson GXT3 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; Installing the Optional Liebert IntelliSlot
  • Page 4 – ii; Shut Down the Liebert
  • Page 5 – iii; FIGURES
  • Page 6 – iv
  • Page 7 – SAVE THESE INSTRUCTIONS; to install or; UPS Safety Notes; in the following environments:; WARNING
  • Page 8 – Battery Safety; ELECTROMAGNETIC COMPATIBILITY; —The Liebert GXT3 complies with the limits for a; Information for the Protection of the Environment; UPS Servicing; CAUTION
  • Page 10 – Product Description; RODUCT; Features; Table 1; Model
  • Page 11 – Appearance and Components; Figure 1
  • Page 12 – Figure 3
  • Page 13 – Figure 4
  • Page 14 – Major Components; The operating principle of the UPS is illustrated in; Figure 6; The Liebert; Dynamic
  • Page 15 – Battery Charger; is plugged; Battery; Operating Mode; Indicators; the UPS maintains the batteries in a fully charged state.; Troubleshooting; energy to the connected load.; NOTICE; NOTE
  • Page 16 – Configuration Program
  • Page 17 – Installation; NSTALLATION; Unpacking and Inspection; Unpack the UPS and conduct the following checks:; What’s Included; With GXT3 UPS; • Liebert MultiLink; Preparation for Installation; Installation Clearances; spacers for tower configuration and one DC power cable.; Operating the Liebert GXT3
  • Page 18 – Mechanical Installation; Figure 7; safety codes and standards
  • Page 19 – Figure 9; d. Replace the front plastic bezel cover on the Liebert; Figure 10 Tower installation
  • Page 20 – Figure 11 Pulling inner member from each slide rail assembly; • When the Liebert; Slide rail assembly
  • Page 21 – Figure 13 Installing front member of each slide rail assembly; Fasten inner members pulled from the slide rail assemblies in; Figure 15 Installing inner members
  • Page 22 – Figure 16 Installing rack-mount handles; sliding the UPS into rack, as shown in; Figure 17 Insert the UPS; rack EIA rails to prevent the UPS from sliding out of position.; and rear members from
  • Page 23 – Cable Connection; cabinets connected to the Liebert GXT3. See; GXT3’s input circuit breaker.; Table 2
  • Page 24 – Connecting Communication Cables; Connecting USB Communication Cables; Figures 3; and; Installing the Optional Liebert IntelliSlot
  • Page 25 – Controls and Indicators; ONTROLS; The operation and display panel, shown in; Figures 1; Figure 18 Operation and display panel; Control Buttons; has three functions (see; Table 3; Liebert; AC Power System
  • Page 26 – The operation and display panel has seven indicators (see; Battery Level Indicators; the battery capacity level. The Liebert; Figure 19 Battery level indicators; Load Level Indicators; Figure 20 Load level indicators; Discharging; Overload
  • Page 27 – inverter indicator and bypass indicator.; shows the symbols and their meaning.; Table 5; UPS Status
  • Page 28 – Operation; PERATION; Startup Checklist for the Liebert GXT3; Turn On the input circuit breaker—see; Manual Battery Test; your local Emerson representative or Emerson Channel Support.; Manual Bypass; indicators are illuminated, refer to
  • Page 29 – UPS will shut down about 30 seconds after the button is pressed.; Disconnecting Input Power from the Liebert GXT3; Once the UPS has been shut down as detailed in
  • Page 30 – Communication; OMMUNICATION; Liebert IntelliSlot Communication Cards
  • Page 31 – USB Port Communication; system using Liebert; Table 6; UPS Model; automatically derated as follows (refer to; • A computer running Windows 2000
  • Page 32 – Terminal Block Communication; The Terminal Block includes eight pins, as shown in; Figure 21 Terminal block communication pin layout; mounted at a remote location.; and Pin 2, the Liebert
  • Page 33 – for remote connection will be via terminal block
  • Page 34 – Maintenance; AINTENANCE; Replacing the Internal Battery Pack; Table 7; UPS Model Number
  • Page 35 – Figure 22 Removing the front bezel cover and battery door; in; Figure 24 Pull out the battery; or Emerson Channel Support.; output power and will drop the connected load.
  • Page 36 – Battery Charging; design life. The Liebert; Precautions; tive or Emerson Channel Support.; Checking UPS Functions; are On and the UPS is operating normally.
  • Page 37 – ROUBLESHOOTING; factors caused the problem and how to remedy the situation.; UPS Symptoms; The following symptoms indicate the Liebert; Table 8; Indicator
  • Page 38 – In the event of an issue with the UPS, refer to; Table 9; Condition; Problem
  • Page 39 – top panel of the Liebert
  • Page 40 – Battery Cabinet; ATTERY; Figure 26 Battery cabinet; UPS or to another battery cabinet.
  • Page 41 – Specifications; PECIFICATIONS
  • Page 43 – Battery cabinet specifications
  • Page 44 – Battery run times; Number of
  • Page 45 – To register for warranty protection, visit the; Quick Links; section of the Liebert; Product Warranty Registration; and fill in the form.; Internal Battery
  • Page 48 – by helping customers optimize their data center; Business-Critical Continuity
Loading the manual

AC Power
For

Business-Critical Continuity™

Liebert

®

GXT3

UPS 120V/208V 500VA-3000VA

User Manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; Installing the Optional Liebert IntelliSlot

i TABLE OF CONTENTS I MPORTANT S AFETY P RECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 S AVE T HESE I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S ...

Page 4 - ii; Shut Down the Liebert

ii 4.0 O PERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.1 Startup Checklist for the Liebert GXT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.2 Starting the UPS . . . . . . ...

Page 5 - iii; FIGURES

iii FIGURES Figure 1 Liebert GXT3 rack/tower models—front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 2 Liebert GXT3 minitower—front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Figure 3 L...

Other Emerson Models