Emerson Fisher 8532- User Manual

Emerson Fisher 8532

Emerson Fisher 8532– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Instruction Manual; End Connection Styles
  • Page 4 – Installation; section of this manual and to the; WARNING; Always wear protective gloves,
  • Page 5 – Use pressure-relieving devices as; See the; at the beginning of the; CAUTION
  • Page 6 – steps can result in damage to
  • Page 7 – Installing the Valve; The maximum allowable inlet pressures for Type
  • Page 8 – Packing Adjustment and Shaft Bonding
  • Page 9 – For PTFE or graphite packing:; Tighten; The ENVIRO-SEAL Packing Systems; will not; Warning; Note
  • Page 10 – Maintenance; even when the valve has; Removing and Replacing the Actuator
  • Page 11 – The packing is now accessible.
  • Page 12 – Removing the Valve
  • Page 13 – PTFE Seals
  • Page 15 – For PTFE or Graphite Packing:; Remove the
  • Page 16 – Installing the Two-Piece Shaft
  • Page 17 – Refer to table 6 for proper torque values.
  • Page 18 – Parts Ordering; Typical parts are shown in figure 9.; Use only genuine Fisher; Retrofit Kits; See table 7 for retrofit kit part numbers.; Repair Kits
  • Page 19 – Parts List
Loading the manual

www.Fisher.com

D101550X012

Type 8532 High Performance Butterfly Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

Description

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Valve Orientation

5

. . . . . . . . . . . . . . . . . . . . . . . . .

Before Installing the Valve

5

. . . . . . . . . . . . . . . . . .

Adjusting the Actuator Travel Stops

or Travel

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installing the Valve

7

. . . . . . . . . . . . . . . . . . . . . . . .

Packing Adjustment and Shaft Bonding

8

. . . . .

Maintenance

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Removing and Replacing the Actuator

10

. . . . . .

Packing Maintenance

10

. . . . . . . . . . . . . . . . . . . . .

Removing the Valve

12

. . . . . . . . . . . . . . . . . . . . . .

Seal Maintenance

12

. . . . . . . . . . . . . . . . . . . . . . . .

PTFE Seals

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

NOVEX, Phoenix III and/or

Phoenix III Fire-Tested Seals

14

. . . . . . . . . .

Anti-Blowout Design, Packing, Valve Shaft,

Disc, and Bearing Maintenance

14

. . . . . . . . . .

Installing the Two-Piece Shaft

16

. . . . . . . . . . . .

Gasket Retainer

17

. . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts List

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction

Scope of Manual

This instruction manual includes installation,
maintenance, and parts ordering information for
NPS 14 through 24, Type 8532 High-Performance
Butterfly Valves (see figure 1). Refer to separate
instruction manuals for information covering the
actuator and accessories.

Do not install, operate, or maintain a Type 8532
valve without first

D

being fully trained and qualified

in valve, actuator, and accessory installation,
operation, and maintenance, and

D

carefully reading

and understanding the contents of this manual. If
you have any questions about these instructions,
contact your Emerson Process Management

t

sales

office before proceeding.

Figure 1. Type 8532 Valve with Type 1061 Actuator and

DVC6020 Digital Valve Controller

W9138-1

Unless otherwise noted, all NACE references are to
NACE MR0175-2002.

Note

Neither Emerson, Emerson Process
Management, nor any of their affiliated
entities assumes responsibility for the
selection, use and maintenance of any
product. Responsibility for the
selection, use, and maintenance of any
product remains with the purchaser
and end-user.

Description

The valve is available in either a flangeless wafer
body or a single-flange (lugged) body design, with a
variety of seals and internal components. The
pressure-assisted seal provides tight shutoff. The
upper (splined) shaft combines with a variety of
pneumatic piston or spring-and-diaphragm
actuators. Maximum inlet pressure/temperature
ratings are consistent with CL150 and CL300.

Instruction Manual

Form 5288
November 2007

8532 Valve

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Instruction Manual; End Connection Styles

8532 Valve Instruction Manual Form 5288 November 2007 2 Table 1. Specifications Valve Size and End Connection Styles J NPS 14, J 16, J 18, J 20, or J 24 valves, in J wafer-style (flangeless) or J single-flange (lugged) with raised-face flanges, CL150 orCL300 Maximum Pressure Drop (1) Consistent with...

Page 4 - Installation; section of this manual and to the; WARNING; Always wear protective gloves,

8532 Valve Instruction Manual Form 5288 November 2007 4 Table 2. Material Temperature Ratings COMPONENT AND MATERIAL OF CONSTRUCTION (1) TEMPERATURE RANGE _ C _ F Body Carbon Steel (WCC or SA 51670) (5) CF8M (316 SST) CL150CF8M FMS 20B16 (0.04% min carbon) CL300 29 to 427198 to 538198 to 816 20 to 8...

Page 5 - Use pressure-relieving devices as; See the; at the beginning of the; CAUTION

8532 Valve Instruction Manual Form 5288November 2007 5 D Use pressure-relieving devices as required by government or acceptedindustry codes and good engineeringpractices to protect fromover-pressurizing the system. D Check with your process or safety engineer for any other hazards thatmay be present...

Other Emerson Models