Emerson 228 - Manual
Emerson 228 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Cutting the cable may void the warranty.
- Page 6 – FIGURE11. Wiring sensors through a remote junction box; WIRING THROUGH A REMOTE JUNCTION BOX
- Page 7 – INSERTION - RETRACTION ASSEMBLIES; the sensor an additional half turn once the gasket is seated.; with the following exception:; Insert the sensor and tube assembly into the retraction chamber.; INSTALLATION REQUIREMENTS
- Page 8 – FIGURE 14. Manual Retraction Assembly; RETRACTION; Place the sensor; NOTE; WARNING; Retraction chamber contents may be under pressure.
- Page 9 – Tighten the union nut.; Do not loosen cap screws or collar when pressurized.
- Page 10 – REPLACING SEALS IN MANUAL AND MECHANICAL RETRACTION ASSEMBLIES.
- Page 11 – FIGURE 16. Mechanical Retraction Assembly Replacement Parts
- Page 12 – FIGURE 17. Manual Retraction Assembly Replacement Parts
- Page 13 – CALIBRATION; If wall effects are present; , calibrating a toroidal sensor with a standard
- Page 14 – CAUTION; TROUBLESHOOTING; PROBLEM
- Page 16 – ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE
Model 228
Submersion/Insertion Toroidal Sensor
Instruction Sheet
PN 51A-228/rev.P
December 2010
SPECIFICATIONS - SENSORS
MODEL
Wetted Materials
Temperature
Pressure CRN pressure*
228-02 PEEK (glass-filled)
248°F (120°C)
295 psig (2135 kPa abs)
220 psig (1618 kPa abs)
228-03 PEEK (glass-filled)
392°F (200°C)
295 psig (2135 kPa abs)
220 psig (1618 kPa abs)
228-04 Tefzel (glass-filled)
248°F (120°C) 200 psig (1480 kPa abs)
150 psig (1135 kPa abs)
228-05 Tefzel (unfilled)
248°F (120°C) 200 psig (1480 kPa abs)
150 psig (1135 kPa abs)
SPECIFICATIONS - ADAPTERS
SPECIFICATIONS - RETRACTION ASSEMBLIES
Operating Conditions
Retraction/Insertion Conditions
PN
Wetted Materials
Temperature
Pressure
Temperature
Pressure
23311-00
392°F
295 psig
392°F
295 psig
(mechanical)
(200°C)
(2135 kPa abs)
(200°C)
(2135 kPa abs)
23311-01
316 SS, Teflon, EPDM
392°F
295 psig
266°F
35 psig
(manual)
(200°C)
(2135 kPa abs)
(130°C)
(343 kPa abs)
PN
Wetted Materials Temperature
Pressure CRN pressure*
23242-02
PEEK, Viton, 316 SS 392°F (200°C)
295 psig (2135 kPa abs) 220 psig (1618 kPa abs)
23242-03 PEEK, Viton, 316 SS 392°F (200°C)
295 psig (2135 kPa abs) 220 psig (1618 kPa abs)
2001990 CVPC, PEEK, Viton 100°F (38°C)
100 psig (791 kPa abs) NA
185°F (85°C)
45 psig (412 kPa abs)
For additional information, please visit our website
at
www.emersonprocess.com/raihome/liquid/
.
*
Maximum pressure for applications requiring CRN registration
*
Maximum pressure for applications requiring CRN registration
316 SS, Teflon, EPDM
316 SS, Teflon, EPDM
NA
CVPC, PEEK, Viton
2001990
WARNING
Before removing the sensor, be absolutely certain
that the process pressure is reduced to 0 psig and
the process temperature is lowered to a safe level!
CAUTION
The wetted sensor materials may not be compatible
with process com position and operating conditions.
Application compat ibility is entirely the responsi-
bility of the user.
CAUTION
SENSOR/PROCESS
APPLICATION COMPATIBILITY
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MODEL 228 INSTALLATION INSTALLATION Keep at least 1 in. (2.5 cm) between the sensor and pipe walls. If the clearance is too small, calibrate the sensorin place. Ensure that the sensor is completely submerged in liquid. Mounting the sensor in a vertical pipe run withthe flow from bottom to top is bes...
MODEL 228 WIRING FIGURE11. Wiring sensors through a remote junction box Wire sensors point to point. For wiring at the analyzer end, refer to the appropriate analyzer wiring diagram. For interconnecting cable 23294-00, use the 2265-54 wiring diagram. For interconnecting cable 23294-04 and 23294-05, ...
7 MODEL 228 USE OF INSERTION - RETRACTION ASSEMBLIES INSERTION - RETRACTION ASSEMBLIES MANUAL RETRACTION ASSEMBLY (PN 23311-01) INSTALLATION 1. Loosen the collet nut and retract the sensor tube into the retraction chamber. See Figure 14. 2. Loosen the union nut and separate the retraction chamber fr...