Emerson 2088 - Manual
Emerson 2088 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Reference Manual
- Page 4 – NOTE
- Page 6 – Make the line tap on the side of the pipe to prevent sediment
- Page 8 – Rosemount 2090P Compatible with 1-in. PMC
- Page 10 – turn with adjustable pliers.; PREPARING THE VESSEL HOLE; DETAIL OF WELD SPUD
- Page 11 – Standard Sanitary Clamp; Power Supply; Typical; DETAIL OF SANITARY; CONNECTION SIZE; Mounting
- Page 12 – Operating
- Page 13 – standard; Jumper Locations; Without a meter installed
- Page 14 – With a meter installed; Transmitter Security; If the transmitter is installed, secure the loop, and remove power.
- Page 15 – Rerange Procedure; Apply a pressure equivalent to the upper range value.
Reference Manual
00809-0100-4690, Rev EA
March 2007
Rosemount 2088 and 2090
www.rosemount.com
Section 3
Installation
OVERVIEW
This section is designed to guide you through a successful Rosemount 2088,
2090F, or 2090P Transmitter installation. Starting with an installation
flowchart, this section contains information on installation considerations and
transmitter options. Dimensional drawings are also included in this section.
SAFETY MESSAGES
Instructions and procedures in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
raises potential safety issues is indicated by a warning symbol ( ). Please
refer to the following safety messages before performing an operation
preceded by this symbol.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Reference Manual 00809-0100-4690, Rev EAMarch 2007 3-3 Rosemount 2088 and 2090 Figure 3-1. Installation Flowchart. Check for Leaks (Process Connections) Zero Trim Transmitter for Mounting Effects Check Jumper or Switches Wire Transmitter Power Transmitter DONE Mount Transmitter Apply Pressure Refer ...
Reference Manual 00809-0100-4690, Rev EA March 2007 Rosemount 2088 and 2090 3-4 GENERAL CONSIDERATIONS The accuracy of the pressure measurement depends on proper installation of the transmitter and impulse piping. The piping between the process and transmitter must accurately transmit pressure to th...
Reference Manual 00809-0100-4690, Rev EA March 2007 Rosemount 2088 and 2090 3-6 Impulse Piping Impulse piping configurations depend on specific measurement conditions. Use the following information and Figure 3-3 as a guideline when installing impulse piping. Liquids: Make the line tap on the side o...