Emerson 1066 - Manual

Emerson 1066

Emerson 1066 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – QUICK START GUIDE – 1066 Liquid Analytical Transmitter; Instruction Sheet
  • Page 3 – Specifications; GENERAL SPECIFICATIONS; Ambient temperature and humidity:
  • Page 4 – FIGURE 2. Power Supply-Current Loop Wiring
  • Page 5 – CONTACTING CONDUCTIVITY; see table below; Recommended Sensors for Conductivity; Temperature range; Temperature specifications:; ±2% of reading outside high recommended range; PERFORMANCE SPECIFICATIONS; Recommended Range – Contacting Conductivity
  • Page 6 – TOROIDAL CONDUCTIVITY; Recommended Range - Toroidal Conductivity; S/cm in recommended range
  • Page 7 – Installation; UNPACKING AND INSPECTION; General Information; tures is not recommended unless a sunshield is used.; PREPARING CONDUIT OPENINGS; conduit before attaching the fitting to the transmitter.; WARNING: RISK OF ELECTRICAL SHOCK; national or local codes.
  • Page 8 – FIGURE 3. Panel Mounting Dimensions
  • Page 11 – FIGURE 6. CSA Installation
  • Page 12 – FIGURE 7. CSA Installation
  • Page 13 – FIGURE 8. CSA Installation
  • Page 14 – FIGURE 9. CSA Label Information
  • Page 16 – FIGURE 11. FM installation
  • Page 17 – FIGURE 12. FM Installation
  • Page 18 – FIGURE 13. FM installation
  • Page 19 – FIGURE 14. FM label information
Loading the manual

NOTICE

Instruction Sheet

1066

LIQ_MAN_ABR_1066-CT-HT-FF-FI

July 2013

1066 Liquid Analytical Transmitter

ESSENTIAL INSTRUCTIONS

Read this page before proceeding!

Emerson designs, manufactures, and tests its Rosemount
Analytical products to meet many national and international
standards. Because these instruments are sophisticated
technical products, you must properly install, use, and main-
tain them to ensure they continue to operate within their
normal specifications. The following instructions must be
adhered to and integrated into your safety program when
installing, using, and maintaining Rosemount Analytical
products. Failure to follow the proper instructions may cause
any one of the following situations to occur: Loss of life; per-
sonal injury; property damage; damage to this instrument;
and warranty invalidation.

• Read all instructions prior to installing, operating, and

servicing the product. If this Instruction Manual is not
the correct manual, telephone 1-800-854-8257 and the
requested manual will be provided. Save this Instruction
Manual for future reference.

• If you do not understand any of the instructions, contact your Emerson representative for clarification.

• Follow all warnings, cautions, and instructions marked on and supplied with the product.

• Inform and educate your personnel in the proper installation, operation, and maintenance of the product.

• Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per

applicable local and national codes. Connect all products to the proper electrical and pressure sources.

• To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.

• When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount.

Unauthorized parts and procedures can affect the product’s performance and place the safe operation of your
process at risk. Look alike substitutions may result in fire, electrical hazards, or improper operation.

• Ensure that all equipment doors are closed and protective covers are in place, except when maintenance is being

performed by qualified persons, to prevent electrical shock and personal injury.

If a Model 475 Universal HART

®

Communicator is used with these transmitters, the software within the Model 475 may

require modification. If a software modification is required, please contact your local Emerson Process Management Service

Group or National Response Center at 1-800-654-7768.

WARNING: EXPLOSION HAZARD

DO NOT OPEN WHILE CIRCUIT IS LIVE. ONLY CLEAN WITH DAMP CLOTH.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - QUICK START GUIDE – 1066 Liquid Analytical Transmitter; Instruction Sheet

QUICK START GUIDE – 1066 Liquid Analytical Transmitter 1. For mechanical installation instructions, see page 8 for panel mounting and page 9 for pipe or wall mounting. 2. Wire the sensor to the main circuit board. See page 10 for wiring instructions. Refer to the sensor instruction sheet for additio...

Page 3 - Specifications; GENERAL SPECIFICATIONS; Ambient temperature and humidity:

Specifications GENERAL SPECIFICATIONS Case: Polycarbonate. IP66 (CSA, FM), NEMA 4X (CSA) Dimensions: Overall 155 x 155 x 131mm (6.10 x 6.10 x 5.15 in.). Cutout: 1/2 DIN 139mm x 139mm (5.45 x 5.45 in.) Conduit openings: Six. Accepts PG13.5 or 1/2 in. conduit fittings Display: Monochromatic graphic li...

Page 4 - FIGURE 2. Power Supply-Current Loop Wiring

4 1066 Instruction Sheet July 2013 LIQ_MAN_ABR_1066-CT-HT-FF-FI Input: One isolated sensor input. Measurement choices of pH/ORP, resistivity/conductivity/TDS, % concentration, total and free chlorine, monochloramine, dissolved oxy- gen, dissolved ozone, and temperature. For contacting conductivity m...

Other Emerson Models