Eaton D77A - Manual

Eaton D77A

Eaton D77A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
Page: / 62

Table of Contents:

  • Page 3 – Important Notice — Please Read; Intelligent Technologies (
  • Page 4 – Table of Contents
  • Page 5 – List of Figures
  • Page 7 – Safety; Definitions and Symbols
  • Page 8 – General Safety; Notice; Módulos I/O D77A El
  • Page 9 – Introduction; Description; All Modules
  • Page 10 – Discrete Combination Modules; Four Analog Channels; — Each module has four analog input channels.; Adjustable Input Filter; Analog Output Modules; Two Analog Channels; — Each analog channel has two analog output channels.; Type Selection; — Each module can be set as a voltage output or a current loop output.; Approval Certifications; Standard; Agency Certifications
  • Page 11 – Catalog Numbering System; D77A I/O modules is illustrated as follows:; Table 2: Catalog Numbering System
  • Page 12 – Specifications; Physical Description; Figure 1; illustrates the front and back of a typical
  • Page 13 – Dimensional Data; Figure 2; illustrates the dimensional data of the; Power Requirements; The current draw for the; Surge Suppression
  • Page 14 – Environmental Specifications; Table 3: Environmental Ratings; Device Default I/O Data
  • Page 15 – Part Number
  • Page 16 – Input Specifications; AC Input Module Specifications; Table 13: AC Input Module Specifications; * A 50V transition range exists between 30V and 80V.; Figure 3: AC Input Module Diagrams; Catalog Number
  • Page 17 – DC Input Module Specifications; Table 14: DC Input Module Specifications; * A 12V transition range exists between 6V and 18V.; Figure 4: DC Input Module Diagrams
  • Page 18 – Analog Input Module Specifications; Table 15: D77A-NI4 Analog Input Module Specifications; Figure 5; for circuit diagram)
  • Page 19 – Figure 5: D77A-NI4 Analog Input Module Diagrams; D77A-NI4 Analog Input Module Specifications on page 10
  • Page 20 – Figure 6: Analog Input Curves; 4 Bit Resolution Equations
  • Page 21 – Output Specifications; AC Output Module Specifications; Table 16: AC Output Module Specifications
  • Page 22 – DC Output Module Specifications; Table 17: DC Output Module Specifications
  • Page 23 – Relay Output Module Specifications; Table 18: Relay Output Module Specifications
  • Page 24 – Analog Output Module Specifications; Table 19: D77A-NQ2 Analog Output Module Specifications; See
  • Page 25 – Figure 11: Analog Output Curves for 14 Bit Resolution
  • Page 26 – Special I/O Specifications; Combination Module Specifications; Table 20: D77A-DI8DQ8 Combination Module Specifications; Figure 12: D77A-DI8DQ8 Combination Module Diagrams
  • Page 27 – Table 21: D77A-DI8RQ8 Combination Module Specifications; Figure 13: D77A-DI8RQ8 Combination Module Diagrams
  • Page 28 – Table 22: D77A-AI8AQ8 Combination Module Specifications; Figure 14: D77A-AI8AQ8 Combination Module Diagrams; V A C
  • Page 29 – Table 23: D77A-AI8RQ8 Combination Module Specifications; * A 60V transition range exists between 80V and 140V.; Figure 15: D77A-AI8RQ8 Combination Module Diagrams
  • Page 30 – Theory of Operation; The; Typical Application; starters with QSNAPs. In this
  • Page 31 – Discrete Input Modules; Figure 17: Discrete Input Module Operation; Discrete Output Modules; the following sequence:; Optical Isolation; — The driver activates the output point.; Figure 18: Discrete Output Module Operation
  • Page 32 – Figure 19: Discrete Combination Module Operation
  • Page 33 – Analog Input Modules; Figure 20: Analog Input Module Operation; Filter Setting; ADC
  • Page 34 – Figure 21: Analog Output Module Operation; QC Port
  • Page 35 – Installation; Setting Group ID; Figure 22: Group ID Switch; DIN rail installation requires one of two procedures:; WARNING
  • Page 36 – Installation Without Backplane; Remove the terminal by unlocking the terminal tabs.; Figure 23: Removable Terminal Locking Tabs; Remove the terminal strip from the module.; Figure 24: Unlock DIN Rail Locking Tab
  • Page 37 – Installing the Module; The module is now ready for installation on the DIN rail.; Push the module straight back; Depress the locking tab to secure the module to the DIN rail.; Figure 25: Lock DIN Rail Locking Tab; Install the terminal strip on the front of the module.; Figure 26: Removable Terminal Locking Tab; CAUTION; QCPort System
  • Page 38 – Installation With Backplane; Figure 27: Removable Terminal Locking Tabs; Figure 28: Unlock DIN Rail Locking Tab
  • Page 39 – Figure 29: Lock DIN Rail Locking Tab; Install the terminal strip on the front of the module.; Figure 30: Removable Terminal Locking Tab
  • Page 40 – QCPort Connections; Interconnects/Connections; Connecting the I/O modules together and to other; QCPort Backplane Interconnect; and; Figure 31: QCPort Backplane Interconnect; GND
  • Page 41 – Pre-manufactured QCPort Interconnect Cables; When making this interconnect, refer to the; Figure 33: QCPort Connector
  • Page 42 – Configuration
  • Page 43 – Field Wiring; Table 25: Symbol Definitions; Symbol
  • Page 44 – CR
  • Page 45 – AC Inputs; . The input devices to which AC inputs are wired are; Figure 35: AC Input Wiring
  • Page 46 – DC Inputs; DC Input; Figure 36: DC Input Wiring
  • Page 47 – Analog Inputs; Analog Input Module Specifications on page 10; Figure 37: Analog Input Wiring
  • Page 48 – AC Outputs; output terminal. Refer to; Figure 38: AC Output Wiring
  • Page 49 – DC Outputs; DC Output; Figure 39: DC Output Wiring
  • Page 50 – Relay Outputs; Relay Output Module Specifications on page 15; Figure 40: Relay Output Wiring
  • Page 51 – Analog Outputs; Analog Output Module Specifications on page 16; Figure 41: Analog Output Wiring
  • Page 53 – Troubleshooting and Maintenance; Status LED; Fault Codes; Table 27: Analog 10 Fault Codes; State
  • Page 54 – Troubleshooting; Table 28: Troubleshooting; Renewal Parts; Explanation of LED Duty Cycle States; Table 30: Explanation of LED Duty Cycle States
  • Page 55 – Communication Hints; Table 32: Communication Hints
  • Page 56 – Appendix A; Data Parameters; * Setting the bit from “0” to “1” indicates that the condition is true.
  • Page 58 – Configuration Parameters; None of the Configuration Parameters support I/O data.; bytes
  • Page 61 – Analog Data Registers; Table 68: Register 3 Analog Filter Setting; Publications and Support; Publications
  • Page 62 – Company Information; Heinemann
Loading the manual

MN05002001E

For more information visit: www.EatonElectrical.com

Intelligent Technologies

(IT.)

D77A I/O Module Products

Installation and User Manual

November 2006
Supersedes October 20 05

Part Numbers
D77A-DI8

D77A-RQ8

D77A-DI16

D77A-RQ16

D77A-DQ8

D77A-DI8DQ8

D77A-DQ16

D77A-DI8RQ8

D77A-AI8

D77A-AI8AQ8

D77A-AI16

D77A-AI8RQ8

D77A-AQ8

D77A-NI4

D77A-AQ16

D77A-NQ2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Important Notice — Please Read; Intelligent Technologies (

Intelligent Technologies ( IT. ) D77A I/O Module Products MN05002001E For more information visit: www.EatonElectrical.com i Important Notice — Please Read The product discussed in this literature is subject to terms and conditions outlined in Eaton Electrical Inc. selling policies. The sole source g...

Page 4 - Table of Contents

ii For more information visit: www.EatonElectrical.com MN05002001E Intelligent Technologies ( IT. ) D77A I/O Module Products Table of Contents LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 5 - List of Figures

Intelligent Technologies ( IT. ) D77A I/O Module Products MN05002001E For more information visit: www.EatonElectrical.com iii List of Figures Figure 1: I/O Module Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Other Eaton Models

All Eaton Other