Desa VYM27PR - Manual
Desa VYM27PR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – UNVENTED PROPANE/LP GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to
- Page 3 – OWNER’S MANUAL; LOCAL CODES; CAUTION: Do not remove the; Figure 1 - Product Identification; OPERATION
- Page 4 – Unusually Tight Construction; per
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
- Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace
- Page 8 – If Not Using Mantel; If using a mantel, proceed to If Using; If Using Mantel; Noncombustible material OK.
- Page 9 – A. If installing appliance on the floor level,; flue damper open; Figure 7 - Minimum Mantel Clearances When Using Hood
- Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Masonry Fireplace
- Page 11 – Attach base assembly to fireplace floor; CAUTION: Never connect; • external regulator (supplied by installer,; WARNING: Never connect; CAUTION: Avoid damage to
- Page 12 – opening propane supply tank valve.; Open propane supply tank valve.; Figure 14 - Gas Connection; Figure 15 - Manual Shutoff Valve; Test Pressures In Excess Of 1/2 PSIG; Figure 16 - Checking Gas Joints
- Page 13 – WARNING: Failure to position; INSTALLING LOGS; Make sure; CAUTION: After installation
- Page 14 – FOR YOUR SAFETY; • If fireplace has glass doors,
- Page 15 – CAUTION: Do not try to adjust; Shutting Off Heater; Lighting; GHRCT Operation
- Page 16 – Figure 25 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; BURNER PRIMARY AIR HOLES; This remote control
- Page 17 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 18 – OBSERVED PROBLEM; nance, page 21) or replace burner orifice
- Page 19 – IMPORTANT
- Page 20 – SPECIFICATIONS; When Gas Pressure Is Too Low; WIRING DIAGRAM; PARTS UNDER WARRANTY
- Page 21 – WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER; Figure 28 - Pilot Inlet Air Hole
- Page 23 – PARTS LIST; Part Number
- Page 24 – ACCESSORIES; FIREPLACE HOOD
- Page 25 – NOTES
- Page 26 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; INTERNATIONAL; NOT A UPC
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
Also Design-Certified As A Vented Decorative Appliance
®
®
Patent Pending
PIL
O T
O
F
F
O
N
LO
REMOTE
OFF
HI
FLAME-MAX
®
Multi-Sided
Log Design
OWNER’S OPERATION AND INSTALLATION MANUAL
VYM27PR
Remote Control
Ready Model
Save this manual for future reference.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational pro-
cedures. For assistance or additional
information consult a qualified installer,
service agency, or the gas supplier.
WARNING: This appliance is for instal-
lation only in a solid-fuel burning ma-
sonry or UL127 factory-built fireplace,
or in an approved ventless firebox. It is
design certified for these installations
in accordance with ANS Z21.11.2.
Exception: Do not install this appli-
ance in a factory-built fireplace that
includes instructions stating it has not
been tested or should not be used with
unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state
or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 104675 UNVENTED PROPANE/LP GAS LOG HEATER VANGUARD FLAME-MAX ® SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble theflu, with headaches, dizziness, or nausea. If youhave these signs, the heater may no...
3 104675 OWNER’S MANUAL AUT O MAN OFF ST ATUS ON LO HI TEMP PRODUCTIDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Available from: American Natio...
4 104675 UNVENTED PROPANE/LP GAS LOG HEATER VANGUARD FLAME-MAX ® PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code. NFPA 54/ANS Z223.1, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowing ventilation classificati...