Table of Contents:
- Page 2 – WARNING: Any change to this heater or its con-; SAFETY INFORMATION; WARNINGS; DANGER: Carbon monoxide poisoning may lead; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; TABLE OF CONTENTS
- Page 3 – PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Continued
- Page 4 – LOCAL CODES; WARNING: Do not remove the data plates from; PRODUCT FEATURES; OPERATION; WARNING: This heater shall not be installed in a
- Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
- Page 6 – WARNING: If the area in which the heater may be; VENTILATION AIR; Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
- Page 7 – Vent-free heaters add moisture to the air. Although; INSTALLATION
- Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; Noncombustible; Noncombustible material OK.; Installing Damper; Figure 4 - Minimum Clearance for Combustible to Wall; If Using Mantel
- Page 9 – A. If installing appliance on the floor level, you must maintain; Figure 7 - Minimum Mantel Clearances When Using Hood; MANTEL CLEARANCES; Determining Minimum Mantel Clearance
- Page 10 – Figure 10 - Attaching Damper Clamp; INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed; Figure 11 - Attaching Flexible Gas Hose to Heater
- Page 11 – Figure 12 - Attaching Base Assembly to Fireplace Floor; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; WARNING: Never connect natural gas heater to; WARNING: Use pipe joint sealant that is resistant
- Page 12 – CAUTION: Avoid damage to control. Hold fitting; Figure 14 - Gas Connection; WARNING: Test all gas piping and connections; CHECKING GAS CONNECTIONS; WARNING: Never use an open flame to check for; Pressure Testing Gas Supply Piping System; Correct all leaks at once.; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 15 - Equipment Shutoff Valve
- Page 13 – Figure 17 - Checking Gas Joints for Propane/LP Gas; WARNING: Failure to position the parts in accor-; INSTALLING LOGS; Make sure log does not cover any burner ports.; CAUTION: After installation and periodically there-
- Page 14 – OPERATING HEATER; FOR YOUR SAFETY READ; WARNING: If you do not follow these instructions; LIGHTING INSTRUCTIONS; • If fireplace has glass doors, never operate this
- Page 15 – CAUTION: Do not try to adjust heating levels by; Figure 23 - Natural Gas Pilot; TO TURN OFF GAS TO APPLIANCE; Shutting Off Heater; MANUAL LIGHTING PROCEDURE; Thermostat Control Operation; OPTIONAL REMOTE OPERATION; GHRC Series Operation:
- Page 16 – GHRCTA Series Operation; manual mode when ON is lit.; PILOT FLAME PATTERN; INSPECTING BURNERS; BURNER FLAME PATTERN; Figure 29 - Correct Flame Pattern
- Page 17 – WARNING: Turn off heater and let cool before; Blow air through the ports/slots and holes in the burner.; Figure 31 - Injector Holder On Outlet Burner Tube; LOGS; • If you remove logs for cleaning, refer to Installing Logs, page; MAIN BURNER
- Page 18 – WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
- Page 19 – OBSERVED PROBLEM; nance, page 17) or replace burner orifice
- Page 20 – IMPORTANT
- Page 21 – WIRING DIAGRAM; SPECIFICATIONS; Natural Gas; SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; REPLACEMENT PARTS; PARTS UNDER WARRANTY
- Page 22 – ILLUSTRATED PARTS BREAKDOWN
- Page 23 – PARTS LIST; PART NUMBER
- Page 24 – EQUIPMENT SHUTOFF VALVE - GA5010; ACCESSORIES
- Page 25 – OWNER'S REGISTRATION FORM
- Page 26 – Postage; TAPE
- Page 27 – NOTES
- Page 28 – KEEP THIS WARRANTY; WARRANTY INFORMATION; LIMITED WARRANTY; NOT A UPC
Also Design-Certified As A Vented Decorative Appliance
Patent Pending
PIL
O T
O
F
F
O
N
LO
REMOTE
OFF
HI
FLAME-MAX
®
Multi-Sided
Log Design
VYM27NR/PR
FVFM27NR/PR
Remote Control
Ready Model
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational proce-
dures. For assistance or additional in-
formation consult a qualified installer,
service agency, or the gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket,* manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
UNVENTED (VENT-FREE)
GAS LOG HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
TM
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
110398-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 Due to high temperatures, the appliance should belocated out of traffic and away from furniture anddraperies. Do not place clot...
110398-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for us...
110398-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of T...