  • Page 2 – UNVENTED GAS LOG HEATER; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:; WARNINGS; WARNING: Any change to
  • Page 3 – OWNER’S MANUAL; PRODUCT IDENTIFICATION; CAUTION: Do not remove the; OPERATION; Figure 1 - Product Identification; Control Knob
  • Page 4 – Unusually Tight Construction; per kw) of the aggregate input
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
  • Page 6 – Ventilation Air From Outdoors; Do not provide openings for; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – INSTALLATION; CHECK GAS TYPE; When installing your gas logs into; *Minimum 16 inches from Side Wall
  • Page 8 – If Not Using Mantel; If using a mantel, proceed to If Using; Noncombustible; Noncombustible material OK.; Installing Damper; If you cannot meet these; If Using Mantel
  • Page 9 – A. If installing appliance on the floor level,; flue damper open; Figure 7 - Minimum Mantel Clearances When Using Hood; Hearth
  • Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Damper; Masonry Fireplace
  • Page 11 – Attach base assembly to fireplace floor; Fitting; WARNING: A qualified service; • external regulator (for propane/LP units; WARNING: Never connect; Install equipment shutoff; Masonry Screw
  • Page 12 – Figure 14 - Gas Connection; Gas Control; Figure 15 - Equipment Shutoff Valve; Open; Correct all leaks at once.; WARNING: Never use an open
  • Page 13 – WARNING: Failure to position; INSTALLING LOGS; Make sure; CAUTION: After installation
  • Page 14 – FOR YOUR SAFETY; • If fireplace has glass doors,
  • Page 15 – CAUTION: Do not try to adjust; Shutting Off Heater; Lighting; GHRC Series Operation:; Figure 23 - Natural Gas Pilot; Pilot Burner
  • Page 16 – PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; This remote control
  • Page 17 – WARNING: Turn off heater; • If you remove logs for cleaning, refer to; Figure 32 - Pilot Inlet Air Hole; Figure 29 - Correct Flame Pattern
  • Page 18 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
  • Page 19 – OBSERVED PROBLEM; nance, page 17) or replace burner orifice
  • Page 20 – IMPORTANT
  • Page 21 – SPECIFICATIONS; Natural Gas; SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; PARTS UNDER WARRANTY
  • Page 23 – PARTS LIST; PART NUMBER
  • Page 24 – ACCESSORIES; FIREPLACE HOOD
  • Page 25 – OWNER'S REGISTRATION FORM
  • Page 26 – Postage
  • Page 27 – NOTES
  • Page 28 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:; NOT A UPC
Loading the manual

UNVENTED (VENT-FREE) GAS LOG HEATER

Also Design-Certified As A Vented Decorative Appliance

OWNER’S OPERATION AND INSTALLATION MANUAL

Patent Pending

PIL

O T

O

F

F

O

N

LO

REMOTE

OFF

HI

FLAME-MAX

®

Multi-Sided

Log Design

VYM27NR/PR

FVFM27NR/PR

Remote Control

Ready Model

Save this manual for future reference.

WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage, per-
sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational proce-
dures. For assistance or additional in-
formation consult a qualified installer,
service agency, or the gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket,* manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

TM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - UNVENTED GAS LOG HEATER; DANGER: Carbon monoxide; Carbon Monoxide Poisoning:; WARNINGS; WARNING: Any change to

2 108382 UNVENTED GAS LOG HEATER FLAME-MAX ® For more information, visit www.desatech.com SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu,with headaches, dizziness, or nausea. If youhave these...

Page 3 - OWNER’S MANUAL; PRODUCT IDENTIFICATION; CAUTION: Do not remove the; OPERATION; Figure 1 - Product Identification; Control Knob

3 108382 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCT IDENTIFICATION LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode, ANSI Z223.1/NFPA 54*. *Available from: American National...

Page 4 - Unusually Tight Construction; per kw) of the aggregate input

4 108382 UNVENTED GAS LOG HEATER FLAME-MAX ® For more information, visit www.desatech.com PROVIDING ADEQUATEVENTILATION The following are excerpts from NationalFuel Gas Code, ANSI Z223.1/NFPA 54, Sec-tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the threefollowin...