- Page 2 – DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to
- Page 3 – OWNER’S MANUAL; Figure 1 - VS24NR Shown; LOCAL CODES; Where listed vented decorative logs; UNPACKING; OPERATION; CAUTION: Do not remove the
- Page 4 – Unusually Tight Construction; per
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
- Page 6 – Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings; Figure 3 - Ventilation Air from Outdoors
- Page 7 – MINIMUM FIREPLACE; INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace
- Page 8 – Requirements for Safe Installation; Noncombustible material OK.; If Using Mantel; If using a mantel, proceed to If Using
- Page 9 – MANTEL CLEARANCES; Figure 7 - Minimum Mantel Clearances When Using Hood; flue damper open; FLOOR CLEARANCES; A. If installing appliance on the floor level,
- Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Masonry Fireplace
- Page 11 – WARNING: Never connect; Figure 13 - Gas Connection; CAUTION: Avoid damage to
- Page 12 – Figure 15 - Checking Gas Joints; Figure 14 - Manual Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.
- Page 13 – WARNING: Failure to position
- Page 14 – WARNING: Burners will come; Figure 21 - Control Knob and Ignitor Button Location; FOR YOUR SAFETY; WARNING
- Page 15 – WARNING: Make sure the; Shutting Off Heater; All remote control accessories must; Thermostat Control Operation; Lighting; Do not leave the se-
- Page 16 – To turn the pilot off,
- Page 17 – WARNING: If yellow tipping; Figure 25 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to
- Page 18 – WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; Figure 30 - Pilot Inlet Air Hole
- Page 19 – POSSIBLE CAUSE; TROUBLESHOOTING; REMEDY; All troubleshooting items are listed in
- Page 20 – nance, page 18) or replace burner orifice; OBSERVED PROBLEM
- Page 21 – IMPORTANT
- Page 22 – PARTS UNDER WARRANTY; SPECIFICATIONS; When Gas Pressure Is Too Low
- Page 23 – FIREPLACE HOOD; ACCESSORIES; FIREBOXES
- Page 25 – PARTS LIST; KEY
- Page 26 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; INTERNATIONAL; NOT A UPC
UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATER
Variable Manually-Controlled Models Also Design-Certified As
Vented Decorative Appliances
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do
not use any phone in your building.
•
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
•
If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or mainte-
nance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational proce-
dures. For assistance or additional in-
formation consult a qualified installer,
service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
®
PI
LOT
O
F
F
O
N
LO
REMOTE
OFF
ON
HI
CFS18NR, VS18NR,
VS24NR VS30NR
18", 24", and 30"
Remote-Ready Models
DESA INTERNATIONAL
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry or UL127 factory-built fire-
place, or in an approved ventless fire-
box. It is design-certified for these
installations in accordance with ANS
Z21.11.2. Exception: Do not install
this appliance in a factory-built fire-
place that includes instructions stat-
ing it has not been tested or should
not be used with unvented gas logs.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 103449 UNVENTED NATURAL GAS LOG HEATER DESA INTERNATIONAL 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any ele...
3 103449 OWNER’S MANUAL PRODUCTIDENTIFICATION Figure 1 - VS24NR Shown LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223, also known as NFPA 54*. *Available from: American National Standards ...
4 103449 UNVENTED NATURAL GAS LOG HEATER DESA INTERNATIONAL Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold air out an...