Desa VP5D - Manual
Desa VP5D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PROPANE/LP GAS HEATERS; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; SAFETY PILOT; LOCAL CODES; American National Standards Institute, Inc.; UNPACKING; Remove heater from carton.
- Page 4 – Confined and Unconfined Space; Unusually Tight Construction
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings for
- Page 7 – Marking Screw Locations; Figure 5 - Mounting Screw Locations; WARNING: Maintain minimum; INSTALLATION; CHECK GAS TYPE; WARNING: Never install the
- Page 8 – Installing Two Mounting Screws; Wall anchors and mounting screws; Attaching To Wall Stud Method; For attaching mounting screw to wall stud; Attaching To Wall Anchor Method; Figure 8 - Tightening Anchors; Removing Front Panel Of Heater; Mark screw location on wall.
- Page 9 – WARNING: A qualified service; Figure 13 - Gas Connection; Hold pressure regulator
- Page 10 – WARNING: Never use an open; Figure 14 - Equipment Shutoff Valve; FOR YOUR SAFETY; Figure 15 - Checking Gas Joints; Correct all leaks at once.
- Page 11 – WARNING: When running; Shutting Off Heater
- Page 12 – PILOT FLAME PATTERN; Figure 20 - Incorrect Pilot Flame Pattern; BURNER FLAME PATTERN; WARNING: Turn off heater; CABINET; Air Passageways; Figure 23 - Pilot Inlet Air Hole
- Page 13 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 14 – OBSERVED PROBLEM
- Page 15 – IMPORTANT; REMEDY
- Page 16 – PARTS LIST
- Page 18 – When Gas Pressure Is Too Low; SERVICE HINTS; PARTS UNDER WARRANTY; ACCESSORY
- Page 19 – NOTES
- Page 20 – INTERNATIONAL; WARRANTY INFORMATION; LIMITED WARRANTY; KEEP THIS WARRANTY; Model; NOT A UPC
Save this manual for future reference.
INFRARED VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
®
VP5D
and
VP10A
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to
Air
For Combustion and Ventilation
section on page 4 of this manual.
WARNING: Improper installation,
adjustment, alteration, service,
or maintenance can cause injury
or property damage. Refer to this
manual for correct installation
and operational procedures. For
assistance or additional infor-
mation consult a qualified in-
staller, service agency, or the
gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
PROPANE/LP GAS HEATERS 2 ® VP5D AND VP10A 104273 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble theflu, with headaches, dizziness, or nausea. Ifyou have these signs, the heater may not beworking properly. Get fresh air at once!Have heater serviced. Some people are morea...
OWNER’S MANUAL 3 104273 PRODUCTIDENTIFICATION PRODUCTFEATURES SAFETY PILOT This heater has a pilot with an OxygenDepletion Sensing (ODS) safety shutoffsystem. The ODS/pilot is a required featurefor vent-free room heaters. The ODS/pilotshuts off the heater if there is not enoughfresh air. PIEZO IGNIT...
PROPANE/LP GAS HEATERS 4 ® VP5D AND VP10A 104273 Confined and Unconfined Space The National Fuel Gas Code ANS Z223.1defines a confined space as a space whosevolume is less than 50 cubic feet per 1,000Btu per hour (4.8 m3 per kw) of the aggre-gate input rating of all appliances installedin that space...