Desa VML27PR - Manual

Desa VML27PR

Desa VML27PR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS
  • Page 3 – PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Continued; Control Knob
  • Page 4 – PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; UNPACKING; OPERATION
  • Page 5 – Confined and Unconfined Space; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION; WARNING: If the area in which the heater may be
  • Page 6 – WARNING: A qualified service person must in-; VENTILATION AIR; Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors; INSTALLATION
  • Page 7 – Figure 4 - Minimum Clearance for Combustible to Wall; *Minimum 16 inches from Side Wall
  • Page 8 – MANTEL CLEARANCES; Determining Minimum Mantel Clearance; Figure 6 - Minimum Mantel Clearances Without Using Hood; Minimum Noncombustible Material Clearances; If Not Using Mantel; If using a mantel, proceed to If Using Mantel. If not using a; If Using Mantel; Noncombustible; Noncombustible material OK.
  • Page 9 – A. If installing appliance on the floor level, you must maintain; Figure 7 - Minimum Mantel Clearances When Using Hood; When used as a vented heater, appliance must be installed; Figure 10 - Attaching Damper Clamp; Damper; Masonry Fireplace
  • Page 10 – Fitting; Figure 11 - Attaching Flexible Gas Hose to Heater; Masonry Screw; WARNING: If installing in a sunken fireplace, special; Installation Items Needed; CAUTION: Do not remove the data plates attached; Installing Remote Receiver; Figure 13 - Disconnecting Jumper Wire from Control Valve; Jumper Wire
  • Page 11 – CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 15 - Connecting Wires; Only use alkaline batteries.; Installing 9-Volt Battery in Receiver; Attach the terminal wires to the battery.; Remove battery cover on back of remote control unit.; Battery Cover; Bracket
  • Page 12 – CHECKING GAS CONNECTIONS; Pressure Testing Gas Supply Piping System; WARNING: Never use an open flame to check for; Install equipment shutoff valve in an accessible; WARNING: Use pipe joint sealant that is resistant; Figure 19 - Gas Connection; Gas Control
  • Page 13 – Figure 22 - Checking Gas Joints for Propane/LP Gas; Figure 20 - Equipment Shutoff Valve; Correct all leaks at once.; Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; WARNING: Failure to position the parts in accor-; INSTALLING LOGS; Make sure log does not cover any burner ports.; CAUTION: After installation and periodically there-
  • Page 14 – OPERATING HEATER; FOR YOUR SAFETY READ; WARNING: If you do not follow these instructions; Logs; Place lava rock around base of heater.
  • Page 15 – LIGHTING; Figure 28 - Control Knob and Ignitor Button Location; Ignitor Button; Figure 29 - Natural Gas Pilot; Pilot Burner
  • Page 16 – Piezo Ignitor; Shutting Off Heater; WARNING: Make sure remote sensor selector; All remote control accessories must be purchased sepa-; TO LOCK
  • Page 17 – INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; PILOT FLAME PATTERN; If pilot flame pattern is incorrect, as shown in Figure 35; BURNER PRIMARY AIR HOLES; Manual Mode; Press the MANU button to turn on the fireplace.; Safety Features; Auto Shutoff Feature
  • Page 18 – Blow air through the ports/slots and holes in the burner.; Figure 36 - Injector Holder On Outlet Burner Tube; Injector Holder; CLEANING AND MAINTENANCE; Burner Tube; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; WIRING DIAGRAM; WARNING: Failure to keep the primary air
  • Page 19 – WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
  • Page 20 – OBSERVED PROBLEM; nance, page 18) or replace burner orifice
  • Page 21 – IMPORTANT
  • Page 22 – ILLUSTRATED PARTS BREAKDOWN
  • Page 23 – PARTS LIST; KEY
  • Page 24 – SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; PARTS UNDER WARRANTY; SPECIFICATIONS; Natural Gas
  • Page 25 – OWNER'S REGISTRATION FORM
  • Page 26 – Postage; T APE
  • Page 27 – ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; For all models. Creates the sound of a real burning fire.
  • Page 28 – WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:; NOT A UPC
Loading the manual

Also Design-Certified As A Vented Decorative Appliance

Patent Pending

O

F

F

PIL

O T

O

N

L O

FLAME-MAX

®

Multi-Sided

Log Design

VML27NR

VML27PR

Remote Control

Ready Model

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or
the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.

WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in a
listed ventless firebox enclosure. It is de-
sign certified for these installations in ac-
cordance with ANSI Z21.11.2. Exception:
Do not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should not
be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to

Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance
is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .

UNVENTED (VENT-FREE) GAS
LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS

111115-01D 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m Due to high temperatures, the appliance should belocated out of traffic and away from furniture anddraperies. Do not place clot...

Page 3 - PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Continued; Control Knob

111115-01D 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PRODUCT IDENTIFICATION LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, us...

Page 4 - PROVIDING ADEQUATE VENTILATION; Unusually Tight Construction; UNPACKING; OPERATION

111115-01D 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSIZ223.1/NFPA 54, Section 5.3, Air for...

Other Desa Models