Desa VGL24NR - Manual
Desa VGL24NR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY INFORMATION; WARNINGS; WARNING: This product contains and/or generates; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNING: Any change to this heater or its controls; TABLE OF CONTENTS
- Page 3 – Continued; PRODUCT IDENTIFICATION
- Page 4 – LOCAL CODES; CAUTION: Do not remove the data plates attached; PRODUCT FEATURES; OPERATION; WARNING: This heater shall not be installed in a
- Page 5 – Unusually Tight Construction; per kw) of the aggregate input rating; AIR FOR COMBUSTION AND VENTILATION
- Page 6 – WARNING: If the area in which the heater may be; VENTILATION AIR; Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; Figure 3 - Ventilation Air from Outdoors
- Page 7 – INSTALLATION; Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE
- Page 8 – Minimum Noncombustible Material Clearances; If Not Using Mantel; Installing Damper; Noncombustible material okay.
- Page 9 – Determining Minimum Mantel Clearances; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain; Figure 6 - Minimum Mantel Clearances Without Using Hood; Figure 7 - Minimum Mantel Clearances When Using Hood
- Page 10 – Manufactured Fireplace; INSTALLING HEATER BASE ASSEMBLY; Installation Items Needed; Figure 11 - Attaching Flexible Gas Hose to Heater
- Page 11 – Figure 12 - Attaching Base Assembly to Fireplace Floor; CONNECTING TO GAS SUPPLY; WARNING: A qualified service person must con-; Figure 13 - External Regulator With Vent Pointing Down
- Page 12 – WARNING: Use pipe joint sealant that is resistant; Figure 14 - Gas Connection; WARNING: Never use an open flame to check for; CHECKING GAS CONNECTIONS; CAUTION: Make sure external regulator has been; Pressure Testing Gas Supply Piping system; Correct all leaks at once.; Figure 15 - Equipment Shutoff Valve; CAUTION: Avoid damage to regulator. Hold gas
- Page 13 – Pressure Testing Heater Gas Connections; Make sure control knob of heater is in the OFF position.; Figure 16 - Checking Gas Joints; Figure 17 - Checking Gas Joints; Installing Remote Receiver; Carefully remove logs and set aside.; Remove heater base from fireplace.; Figure 19 - Disconnecting Jumper Wire from Control Valve
- Page 14 – INSTALLING LOGS; WARNING: Failure to position the parts in accor-; Figure 21 - Connecting Wires; Installing 9-Volt Battery in Receiver; Figure 20 - Installing Remote Receiver
- Page 15 – WARNING: If you do not follow these instructions; OPERATING HEATER; FOR YOUR SAFETY READ; CAUTION: Placing lava rock on or around front
- Page 16 – CAUTION: Do not try to adjust heating levels by; TO TURN OFF GAS; Shutting Off Heater; Natural Gas; WARNING: Damper handle will be hot if heater; • If fireplace has glass doors, never operate this; LIGHTING; Figure 29 - Control Knob and Ignitor Button Location
- Page 17 – Hand-held remote control accessories must be purchased; WARNING: Burners will come on automatically; REMOTE OPERATION; Manual Mode; TO LOCK; WARNING: Make sure the selector switch is in the
- Page 18 – Figure 35 - Incorrect Pilot Flame Pattern; MAIN BURNER; INSPECTING BURNERS; Check pilot flame pattern and burner flame patterns often.; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to Appliance, page 16); Figure 34 - Correct Pilot Flame Pattern; Press AUTO button to select this mode.; Safety Features; Auto Shutoff Feature
- Page 19 – WARNING: Turn off heater and let cool before; Blow air through the holes in the burner.; Figure 36 - Injector Holder On Outlet Burner Tube; Figure 37 - Pilot Inlet Air Hole; LOGS; • If you remove logs for cleaning, refer to Installing Logs, pages; CLEANING AND MAINTENANCE; WARNING: Failure to keep the primary air
- Page 20 – TROUBLESHOOTING; WARNING: Turn off heater; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 21 – OBSERVED PROBLEM; nance, page 19) or replace burner orifice
- Page 22 – IMPORTANT
- Page 23 – TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS; PARTS UNDER WARRANTY; SPECIFICATIONS; WIRING DIAGRAM
- Page 24 – ILLUSTRATED PARTS BREAKDOWN
- Page 25 – PARTS LIST; KEY
- Page 26 – ACCESSORIES
- Page 27 – OWNER'S REGISTRATION FORM
- Page 28 – Postage; T APE
- Page 29 – NOTES
- Page 30 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; LIMITED WARRANTY
UNVENTED (VENT-FREE)
GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
S a v e t h i s m a n u a l f o r f u t u r e r e f e r e n c e .
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• D o n o t t o u c h a n y e l e c t r i c a l
switch; do not use any phone in
your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, ser-
vice agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile)
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Also Design-Certified As Vented Decorative Appliances When
Not Used With Hand-Held Thermostat Remote
WARNING: Improper installation, adjustment, al-
teration, service, or maintenance can cause injury
or property damage. Refer to this manual for cor-
rect installation and operational procedures. For
assistance or additional information consult a quali-
fied installer, service agency, or the gas supplier.
WARNING: This appliance is for installation only
in a solid-fuel burning masonry or UL127 factory-
built fireplace, or in a listed ventless firebox en-
closure. It is design-certified for these installa-
tions in accordance with ANSI Z21.11.2.
Exception: Do not install this appliance in a fac-
tory-built fireplace that includes instructions stat-
ing it has not been tested or should not be used
with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and
ventilation air must be provided. Refer to
Air for
Combustion and Ventilation section on page 4.
VGL24NR
VGL24PR
24" Remote Ready
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
111640-01B 2 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION WARNINGS WARNING: This product contains and/or generates chemicals known...
111640-01B 3 3 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m SAFETY INFORMATION PRODUCT IDENTIFICATION 1. This appliance is only for use with the type of gas indicated onthe rating plate...
111640-01B 4 F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m LOCAL CODES Install and use heater with care. Follow all local codes. In theabsence of local codes, use the latest edition of T...