Desa VFN30MV - Manual
Desa VFN30MV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Carbon Monoxide Poisoning:; WARNINGS; WARNING: Any change to
- Page 3 – OWNERS MANUAL; Figure 1 - Ember Master; OPERATION; UNPACKING; CAUTION: Do not remove the; Continued; LOCAL CODES
- Page 4 – Confined and Unconfined Space; per; Unusually Tight Construction
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Ventilation Air From Outdoors; Do not provide openings for; Figure 2 - Ventilation Air from Inside Building
- Page 7 – INSTALLATION; CHECK GAS TYPE; When installing your gas logs
- Page 8 – Noncombustible material OK.; If Not Using Mantel; If using a mantel, proceed to If Using; Installing Damper; If Using Mantel; If you cannot meet these
- Page 9 – FLOOR CLEARANCES; A. If installing appliance on the floor level,; Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; flue damper open
- Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Manufactured Fireplace; Area of Various Standard Round Flues
- Page 11 – Attach mounting brackets to fireplace; CAUTION: Avoid damage to; Figure 13 - Gas Connection; * Minimum inlet pressure for purpose of input adjustment.; WARNING: Never connect; Install an equipment shutoff
- Page 12 – WARNING: Never use an open; Figure 14 - Equipment Shutoff Valve; Figure 15 - Checking Gas Joints; Correct all leaks at once.
- Page 14 – FOR YOUR SAFETY; • If fireplace has glass doors,; WARNING: Damper handle
- Page 15 – WARNING: Do not operate; Shutting Off Heater; WARNING: If yellow tipping; Figure 23 - Correct Pilot Flame Pattern; Figure 24 - Incorrect Pilot Flame Pattern; • turn heater off (see To Turn Off Gas to
- Page 16 – SPECIFICATIONS; Figure 28 - Pilot Inlet Air Hole; LOGS
- Page 17 – TROUBLESHOOTING; POSSIBLE CAUSE
- Page 19 – IMPORTANT; OBSERVED PROBLEM
- Page 21 – PARTS LIST; KEY
- Page 22 – PARTS UNDER WARRANTY; ACCESSORIES; FIREPLACE HOOD; When Gas Pressure Is Too Low; SERVICE HINTS
- Page 23 – NOTES
- Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; INTERNATIONAL
UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATER
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
Save this manual for future reference.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: Improper installation, ad-
justment, alteration, service, or main-
tenance can cause injury or property
damage. Refer to this manual for cor-
rect installation and operational pro-
cedures. For assistance or additional
information consult a qualified installer,
service agency, or the gas supplier.
VFN18MV,
VFN24MV
VFN30MV
Variable Manually-
Controlled
LO
PILOT
OFF
HI
EMBER MASTER
™
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation section on page 4 of this manual.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design-
certified for these installations in accor-
dance with ANS Z21.11.2. Exceptions:
Do not install this appliance in a factory-
built fireplace that includes instructions
stating it has not been tested or should
not be used with unvented gas logs.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance may be installed in an aftermarket*, permanently located, manufac-
tured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 105070 FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATER 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do ...
3 105070 OWNERS MANUAL PRODUCTIDENTIFICATION Figure 1 - Ember Master Left Front Log Control Knob Rear Log Base Assembly FrontBurner PiezoIgnitor RearBurner Crossover Log BottomMiddle Log Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of ...
4 105070 FIREPLACE MANUFACTURERS INCORPORATEDUNVENTED NATURAL GAS LOG HEATER Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1defines a confined space as a space whosevolume is less than 50 cubic feet per 1,000Btu per hour (4.8 m 3 per kw) of the aggre- gate input rating of all ap...