  • Page 2 – Carbon Monoxide Poisoning:; Early signs of carbon monoxide; Get fresh air at once!; Have heater serviced. Some people are more; WARNINGS
  • Page 3 – Continued; PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Installing Damper; SAFETY INFORMATION
  • Page 4 – LOCAL CODES; The National Fuel Gas Code; UNPACKING; PROVIDING ADEQUATE VENTILATION; National Fuel Gas Code, ANSI; Unusually Tight Construction; PRODUCT FEATURES; OPERATION
  • Page 5 – Confined and Unconfined Space; defines a; DETERMINING FRESH-AIR FLOW FOR; Determining if You Have a Confined or Unconfined; Ventilation Air From Inside
  • Page 6 – VENTILATION AIR; Ventilation Air From Inside Building; Ventilation Air From Outdoors; National Fuel Gas Code, ANSI; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – INSTALLATION AND CLEARANCES FOR; Vent-free heaters add moisture to the air. Although; CHECK GAS TYPE; LOG SIZING REQUIREMENTS; INSTALLATION
  • Page 8 – Minimum Clearances For Side Combustible; Figure 4 - Minimum Clearance for Combustible to Wall; Noncombustible; Minimum Noncombustible Material Clearances; If Not Using Mantel; If using a mantel proceed to; If Using Mantel; If you cannot meet these minimum clearances, you
  • Page 9 – MANTEL CLEARANCES; Determining Minimum Mantel Clearance; FLOOR CLEARANCES; A. If installing appliance on the floor level, you must maintain the
  • Page 10 – When used as a vented decorative, appliance must be installed; Area of Various Standard; INSTALLING HEATER ASSEMBLY; Make sure the heater burners are level. If heater is; Installation Items Needed; Install optional GHRCTA Receiver and Hand-Held Remote
  • Page 11 – Accessories; CONNECTING TO GAS SUPPLY; Install equipment shutoff valve in an accessible; Supply Tank
  • Page 12 – from your dealer. See; Connecting to Gas Supply; Pressure Testing gas Supply Piping system; CHECKING GAS CONNECTIONS; Pressure Testing Heater Gas Connections; Operating Heater
  • Page 14 – OPERATING HEATER; FOR YOUR SAFETY READ; Figure 17 - Control Knob and Ignitor Button Location,
  • Page 15 – Figure 18 - Control Knob and Ignitor Button Location,; Manual; Shutting Off Heater; TO TURN OFF GAS TO APPLIANCE; MANUAL LIGHTING PROCEDURE; Lighting Instructions; Remote Control Operation; REMOTE CONTROL OPERATION
  • Page 16 – Do not leave the selector switch in the RE-
  • Page 17 – BURNER FLAME PATTERN; NOTICE: Do not mistake orange flames with yellow; INSPECTING BURNERS; PILOT FLAME PATTERN; To Turn Off Gas to Appliance; Figure 22 - Correct Pilot Flame Pattern (Your pilot may vary; Figure 25 - Incorrect Burner Flame Pattern; Figure 23 - Incorrect Pilot Flame Pattern (Your pilot may vary
  • Page 18 – at least thirty minutes.; CLEANING AND MAINTENANCE; Figure 26a - Injector Holder Front Burner Tube; Figure 27 - Pilot Inlet Air Hole (Your pilot may vary from pilots; if compressed air is not available.; LOGS; • If you remove logs for cleaning, refer to
  • Page 19 – plug heater and let cool before; POSSIBLE CAUSE; Cleaning and; OBSERVED PROBLEM; TROUBLESHOOTING
  • Page 21 – IMPORTANT; REMEDY
  • Page 22 – SPECIFICATIONS
  • Page 23 – When Gas Pressure Is Too Low; TECHNICAL SERVICE; Use only original replacement parts. This will protect your; PARTS UNDER WARRANTY; WIRING DIAGRAM; SERVICE HINTS
  • Page 24 – ILLUSTRATED PARTS BREAKDOWN
  • Page 26 – Replacement Parts; PARTS LIST
  • Page 27 – FIREBOXES; Circulating fireboxes feature; ACCESSORIES; EQUIPMENT SHUTOFF VALVE - GA5010; Helps deflect heat away from mantel or wall above
  • Page 28 – THIS PAGE INTENTIONALLY LEFT BLANK
  • Page 29 – • ACCESSORIES; OWNER'S REGISTRATION FORM
  • Page 31 – NOTES
  • Page 32 – NOT A UPC; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; LIMITED WARRANTY; For information about this warranty write:
Loading the manual

UNVENTED (VENT-FREE) GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Design Dynamics Vent-free Models Also Design-Certified As Vented Decorative Appliances

Save this manual for future reference.

WARNING: If the information in this manual

is not followed exactly, a fire or explosion

may result causing property damage, per-

sonal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity

of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed

by a qualified installer, service agency, or

the gas supplier.

WARNING: Improper installation, adjust-

ment, alteration, service, or maintenance

can cause injury or property damage. Refer

to this manual for correct installation and

operational procedures. For assistance

or additional information consult a quali-

fied installer, service agency, or the gas

supplier.

WARNING: This appliance is for instal-

lation only in a solid-fuel burning masonry

or UL127 factory-built fireplace, or in an

approved ventless firebox. It is design-

certified for these installations in accor-

dance with ANSI Z21.11.2. Exception: Do

not install this appliance in a factory-built

fireplace that includes instructions stating

it has not been tested or should not be

used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it

is installed. Provisions for adequate combustion and ventilation air must be provided. Refer

to

Air for Combustion and Ventilation

section on page 4 of this manual.

This appliance may be installed in an aftermarket,* manufactured (mobile) home, where not

prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Warning: This product must be installed by a Licensed Plumber or Gas Fitter when installed

within The Commonwealth of Massachusetts.

For more information, visit www.desatech.com

V F - 2 4 N - E M U
V F - 2 4 P - E M U
V F - 1 8 N - E M U
V F - 1 8 P - E M U

ANSI Z21.11.2-2002
Approved

Certified

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Carbon Monoxide Poisoning:; Early signs of carbon monoxide; Get fresh air at once!; Have heater serviced. Some people are more; WARNINGS

111826-05 For more information, visit www.desatech.com 2 TABLE OF CONTENTS SAFETY INFORMATION .............................................................. 2PRODUCT IDENTIFICATION ....................................................... 3OPTIONAL REMOTE CONTROL ACCESSORIES ...................... 4LO...

Page 3 - Continued; PRODUCT IDENTIFICATION; Figure 1 - Product Identification; Installing Damper; SAFETY INFORMATION

111826-05 For more information, visit www.desatech.com 33 SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 1 - Product Identification 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not p...

Page 4 - LOCAL CODES; The National Fuel Gas Code; UNPACKING; PROVIDING ADEQUATE VENTILATION; National Fuel Gas Code, ANSI; Unusually Tight Construction; PRODUCT FEATURES; OPERATION

111826-05 For more information, visit www.desatech.com 4 LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54 *. *Available from: American National Standards Institute, Inc. 1430 ...