Desa SL-5512 - Manual

Desa SL-5512

Desa SL-5512 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – INSTALLATION
  • Page 3 – SPECIFICATIONS; Motion; TEST AND ADJUSTMENT; Maximum Range; Least Sensitive
  • Page 4 – TROUBLESHOOTING GUIDE; No Service Parts Available for this Product; TECHNICAL SERVICE; TEN YEAR LIMITED WARRANTY
  • Page 5 – FUNCIONAMIENTO; Resumen de las modalidades del interruptor; PRUEBA; Prueba; DUAL BRITETM
  • Page 6 – INSTALACION; CUIDADO: Para evitar los peligros de incendio
  • Page 7 – PRUEBA Y AJUSTE; Lo menos sensible; ESPECIFICACIONES; Angulo de
  • Page 8 – GUIA DE INVESTIGACION DE AVERIAS; GARANTÍA LIMITADA A DIAZ AÑOS; SERVICIO TÉCNICO; No hay piezas de servicio disponibles para este producto
  • Page 9 – Exigences; FONCTIONNEMENT; Minuterie Dual BriteTM; Résumé du mode de commutation
  • Page 10 – D’É; AVERTISSEMENT: Pour éviter les risques de
  • Page 11 – Le moins sensible
  • Page 12 – GUIDE DE DÉPANNAGE; GARANTIE LIMITÉE DE DIX ANS; Aucune pièce de rechange n’est disponible pour ce produit; SERVICE TECHNIQUE
Loading the manual

© 2005 DESA Specialty Products™

595-5575-06

Dual Brite™ Twin
Halogen Motion
Sensing Light

Model SL-5512

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight

hours.

• LED indicates motion was sensed (day or night).

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Cover

Plate

Light Control

Sensor

3 Wire

Connectors

Gasket

6 Mounting

Screws (3 sizes)

Mounting Bolt

Mounting Strap

Rubber Plug

OPERATION

* resets to Auto Mode at dawn.

TEST

TEST

1 5 20

ON-TIME

Off

3 6 Dusk to

Dawn

DUAL BRITE™

Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.

MANUAL MODE

ON-TIME

TEST

1 5 20

... back on.

AUTO

1 Second OFF

then...

Dual Brite™ TIMER

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5 or 20 minutes)
then returns to dim mode.

Move ON-TIME Switch to

1, 5 or 20 minutes

Mode Switching Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Light Shield

Plastic Hanger

2 Halogen Bulbs

This package includes:

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Mode:

On-Time:

Works: Day Night

Test

5 Sec

x

x

Auto

1, 5, 20 min.

x

Manual

Until Dawn*

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION

2 595-5575-06 INSTALLATION For easy installation, select an existing light operated by a wall switch for replacement.For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. CAUTION: Keep the sensor at least 1" (2.5 cm) away from the lamps. ❒ Place the Mounting Bolt through t...

Page 3 - SPECIFICATIONS; Motion; TEST AND ADJUSTMENT; Maximum Range; Least Sensitive

3 595-5575-06 SPECIFICATIONS Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [ v a r i e s w i t h s u r r o u n d i n g temperature] Sensing Angle . . . . . . Up to 240°Electrical Load . . . . . . Up to 300 Watt Maximum Incan- descent [Up to 150 Maximum each la...

Page 4 - TROUBLESHOOTING GUIDE; No Service Parts Available for this Product; TECHNICAL SERVICE; TEN YEAR LIMITED WARRANTY

4 595-5575-06 POSSIBLE CAUSE 1. A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects) . 2. Sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted ...