Desa RG30P - Manual

Desa RG30P

Desa RG30P – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Air for Combustion and Ventilation; section on page 5 of this manual.; TABLE OF CONTENTS; State of Massachusetts:; wealth of Massachusetts.
  • Page 3 – SAFETY INFORMATION; Carbon Monoxide Poisoning:; Get fresh; Air for
  • Page 4 – LOCAL CODES; National Fuel Gas Code, ANSI; Continued; Ignitor Button; PRODUCT; SAFETY DEVICE
  • Page 5 – National Fuel; Unusually Tight Construction; Ventilation Air From Outdoors; Confined and Unconfined Space
  • Page 6 – Ventilation; National Fuel Gas Code,
  • Page 7 – Figure 3 - Ventilation Air from Outdoors; VENTILATION AIR; Ventilation Air From Inside Building; National Fuel Gas; Ventilation Air From Outdoors; Section 5.3, Air for Combustion and Ventilation; AIR FOR COMBUSTION; INSTALLATION; CHECK GAS TYPE
  • Page 8 – INSTALLATION ITEMS; Accessorie; LOCATING HEATER; Accessories; Air
  • Page 9 – Figure 5 - Attaching Thermostat Sensing; INSTALLING HEATER TO WALL; Mounting Bracket; Figure 7 - Removing Front Panel Of; Figure 6 - Mounting Bracket; Removing Front Panel Of Heater; Marking Screw Locations; mum clearances shown in Figure
  • Page 10 – Attaching Mounting Bracket To Wall; Only Insert Mounting; Horizontal Slots
  • Page 11 – Wall; Installing Bottom Mounting Screws; Attaching To
  • Page 12 – CONNECTING TO GAS SUPPLY; Figure 14 - External Regulator With Vent
  • Page 13 – CHECKING GAS CONNECTIONS; WARNING: Test all gas piping; Test Gauge Connection*; ing to Gas Supply; Figure 15 - Gas Connection
  • Page 15 – just heating levels by using the; OPERATING HEATER; MANUAL CONTROL MODELS; FOR YOUR SAFETY; low these instructions exactly,; LIGHTING; Figure 19 - Control Knob In The OFF
  • Page 16 – Figure 21 - Control Knob In The OFF; Shutting Off Heater; Lighting; THERMOSTAT CONTROLLED
  • Page 17 – Manual Lighting Procedure; Ignitor Electrode
  • Page 18 – BURNER FLAME PATTERN; INSPECTING HEATER; PILOT FLAME PATTERN; Figure 24 - Incorrect Pilot Flame Pattern; Heat
  • Page 19 – BURNER PILOT AIR INLET; Figure 27 - Pilot Inlet Air; CABINET; Air Passageways
  • Page 20 – TROUBLESHOOTING; WARNING: Turn off and unplug heater and let cool before servicing.; POSSIBLE CAUSE; Cleaning
  • Page 22 – OBSERVED PROBLEM
  • Page 23 – IMPORTANT
  • Page 24 – SPECIFICATIONS
  • Page 25 – SERVICE HINTS; When Gas Pressure Is Too Low; TECHNICAL SERVICE; PARTS UNDER WARRANTY; Parts Central
  • Page 26 – ILLUSTRATED PARTS BREAKDOWN; MODELS
  • Page 27 – PARTS LIST; listed under; PART NUMBER
  • Page 30 – ACCESSORIES; For all piezo ignitor models.
  • Page 31 – PARTS CENTRALS; East Coast Energy Products
  • Page 32 – NOT A UPC; LIMITED WARRANTY; WARRANTY INFORMATION; KEEP THIS WARRANTY
Loading the manual

Save this manual for future reference.

For more information, visit www.desatech.com

WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other

appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

— Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

BG30N, BG30NT, BG30P, BG30PT, FG30N, FG30NT, FG30P,

FG30PT, GG30N, GG30NT, GG30P, GG30PT, RG30N, RG30NT,

RG30P, RG30PT, GMG30N, GMG30NT, GMG30P, GMG30PT

UNVENTED (VENT-FREE) BLUE FLAME GAS GARAGE HEATER

SAFETY INFORMATION AND INSTALLATION MANUAL

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Air for Combustion and Ventilation; section on page 5 of this manual.; TABLE OF CONTENTS; State of Massachusetts:; wealth of Massachusetts.

www.desatech.com 114683-01B 2 WARNING: Improper installation, adjustment, altera-tion, service or maintenance can cause injury or prop-erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi-tional information consult a qualified installer, servic...

Page 3 - SAFETY INFORMATION; Carbon Monoxide Poisoning:; Get fresh; Air for

www.desatech.com 114683-01B 3 SAFETY INFORMATION IMPORTANT: Read this owner’s manual carefully and completely b e f o r e t r y i n g t o a s s e m b l e , operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and ...

Page 4 - LOCAL CODES; National Fuel Gas Code, ANSI; Continued; Ignitor Button; PRODUCT; SAFETY DEVICE

www.desatech.com 114683-01B 4 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run...

Other Desa Models