Desa MSVFBP - Manual
Desa MSVFBP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SUN VALLEY STOVE COMPANY; Carbon Monoxide Poisoning:; WARNINGS; DANGER: Carbon monoxide
- Page 3 – OWNER’S MANUAL; LOCAL CODES; American National Standards Institute, Inc.; OPERATION
- Page 4 – Unusually Tight Construction; per
- Page 5 – Determining if You Have a Confined or Unconfined Space
- Page 6 – Figure 3 - Ventilation Air from Outdoors; Ventilation Air From Outdoors; Do not provide openings; Figure 2 - Ventilation Air from Inside Building; VENTILATION AIR
- Page 7 – WARNING: Never install the; INSTALLATION; CAUTION: This heater creates; CHECK GAS TYPE; Front View; You must maintain mini-
- Page 8 – Figure 6 - Laying Down Stove On Side; Figure 7 - Removing Pallet Wood From The Bottom of The Stove; STOVE CAVITY ASSEMBLY; Remove plastic bag from stove body.; Figure 5 - Removing Back Panel
- Page 9 – Figure 9 - Attaching Stove Legs; Figure 11 - Attaching Stove Door; Attach stove door by inserting step bolt
- Page 10 – Do not pick up gas log; Make sure log does not; CAUTION: Do not remove the
- Page 11 – WARNING: Never connect; WARNING: A qualified service; Installation Items Needed; Back View
- Page 12 – CAUTION: Avoid damage to; WARNING: Never use an open; Correct all leaks at once.; Figure 21- Equipment Shutoff Valve; Figure 22 - Checking Gas Joints
- Page 13 – WARNING: Installation must; The wire; WARNING: Do not connect; Figure 24 - Back View of Thermostat Base; Set the temperature adjustment to the
- Page 14 – LIGHTING; WARNING: Burners will come
- Page 15 – Shutting Off Heater; Lighting; Thermostat Control Operation; GHRC Series Operation:
- Page 16 – WARNING: Do not operate
- Page 17 – Figure 32 - Correct Pilot Flame Pattern; • turn heater off (see To Turn Off Gas to; Figure 34 - Correct Pilot Flame Pattern
- Page 18 – WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER; Removing the rear panel; Figure 37 - Pilot Inlet Air Hole; TRANSPORTING STOVE
- Page 19 – TROUBLESHOOTING; POSSIBLE CAUSE; nance, page 18) or replace burner orifice; OBSERVED PROBLEM; All troubleshooting items are listed in
- Page 21 – IMPORTANT; Operating heater where impurities in air exist may create odors.
- Page 22 – PARTS UNDER WARRANTY; SERVICE HINTS; When Gas Pressure Is Too Low; WIRING DIAGRAM; Note; SPECIFICATIONS
- Page 23 – ACCESSORIES
- Page 24 – MSVFBPR
- Page 25 – PARTS LIST; KEY
- Page 26 – MSVFBP
- Page 28 – SUN VALLEY STOVE
- Page 29 – PARTS AVAILABLE — NOT SHOWN
- Page 32 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; INTERNATIONAL; Sun Valley; or
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage. Re-
fer to this manual for correct installation
and operational procedures. For assis-
tance or additional information consult a
qualified installer, service agency, or the
gas supplier.
WARNING: The MSVFBP(R) series vent-free
gas log heater is only approved for use in the
Sun Valley MC(*) series and MCH(P) series
cast iron stove models.
(* Indicates Color Suffix Designation)
Save this manual for future reference.
(VENT-FREE) PROPANE/LP GAS STOVE HEATER
Patent Pending
Sun Valley Stove Model MSVFBP Series
Variable Manual-Control or Model MSVFBPR
Series Remote-Ready Gas Log Heater
(Burner System For Cast Iron Stoves)
OWNER’S OPERATION AND INSTALLATION MANUAL
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
For technical support call DESA
International’s Technical Service
Department at 1-800-DESALOG
(1-800-337-2564).
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate
combustion and ventilation air must be pro-
vided. Refer to
Air for Combustion and Ven-
tilation section on page 4 of this manual.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 105986 VENT-FREE PROPANE/LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information, visit www.desatech.com SAFETYINFORMATION IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater cancause serious...
3 105986 OWNER’S MANUAL For more information, visit www.desatech.com LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes,use the latest edition of The National FuelGas Code ANS Z223.1, also known asNFPA 54*. *Available from: American National Standards ...
4 105986 VENT-FREE PROPANE/LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information, visit www.desatech.com AIR FORCOMBUSTION ANDVENTILATION Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in hom...